<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-5684890127023020349</id><updated>2011-09-11T06:32:55.924-07:00</updated><category term='alto voltaje'/><category term='radiometría'/><category term='myrkos'/><category term='medida electrica'/><category term='camara termografica amperis tei'/><category term='v-switch'/><category term='ohmetro'/><category term='microhmetro'/><category term='generadores'/><category term='infrarrojos'/><category term='puesta a tierra'/><category term='medidor de tensión'/><category term='analizadores'/><category term='manuales'/><category term='resistencia'/><category term='termografía medica'/><category term='termitas'/><category term='comprobaciones'/><category term='rendimiento'/><category term='verificación'/><category term='tiempo RL'/><category term='redes eléctricas'/><category term='tarifas'/><category term='megóhmetros'/><category term='inspección'/><category term='mediciones'/><category term='medidores'/><category term='inductancia'/><category term='unidades'/><category term='SARS'/><category term='camaras termográficas'/><category term='fallos'/><category term='ahorro'/><category term='videomanual'/><category term='megger'/><category term='termografía'/><category term='controles'/><category term='aislamiento eléctrico'/><category term='descargas parciales'/><category term='osciloscopios'/><category term='ohmímetros'/><category term='plagas'/><category term='electricas'/><category term='errores'/><category term='paneles'/><category term='cromatógrafo'/><category term='redes'/><category term='cámaras termográficas'/><category term='absolutas'/><category term='baterias'/><category term='ensayos'/><category term='telurometros'/><category term='impedancia'/><category term='aceite'/><category term='micróhmetros'/><category term='laboratorio'/><category term='cámaras térmicas'/><category term='capacidad'/><category term='mecanismos'/><category term='calibración'/><category term='ohmetros'/><category term='capacitancia'/><category term='transformadores'/><category term='resistencias'/><category term='resistores'/><category term='medidas'/><category term='intervalos'/><category term='descargador baterias'/><category term='medidor de rigidez'/><category term='microhmetros'/><category term='tension de ruptura'/><category term='gases'/><category term='medida'/><category term='frecuencia'/><category term='descarga parcial'/><category term='aceite dieléctrico'/><category term='amperis'/><category term='métodos'/><category term='calibrar'/><category term='ruptura'/><category term='house'/><category term='de mano'/><category term='óhmetros'/><category term='tensión'/><category term='patrones'/><category term='iberdrola'/><category term='telurómetros'/><category term='IR'/><category term='alta tecnología'/><category term='multímetro'/><category term='chispometro'/><category term='aislamiento'/><title type='text'>Instrumentación eléctrica y equipos de ensayo</title><subtitle type='html'>Equipos de medida, test y mantenimiento eléctrico.
medidas eléctricas, instrumentación de mano, equipos de ensayo y diagnóstico de subestaciones, líneas y centros de transformación.</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>45</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-8898238162468417221</id><published>2011-05-27T08:10:00.000-07:00</published><updated>2011-05-27T08:56:02.429-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='camara termografica amperis tei'/><category scheme='http://www.blogger.com/atom/ns#' term='house'/><category scheme='http://www.blogger.com/atom/ns#' term='amperis'/><category scheme='http://www.blogger.com/atom/ns#' term='camaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='termografía medica'/><title type='text'>El Dr. House trabaja con Cámaras Termográficas Amperis TEi</title><content type='html'>En el capítulo 24 de la 5º Temporada emitido por Cuatro, el día 25/05/2011, House utiliza la cámara termográfica TEi, para uno de sus análisis médicos.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/-03c-UeC2tfU/Td_JcTUEtHI/AAAAAAAAAeA/g7OpHEEeQ0I/s1600/dr-house-usa-camaras-termograficas-amperis.jpg"&gt;&lt;img style="cursor:pointer; cursor:hand;width: 400px; height: 226px;" src="http://3.bp.blogspot.com/-03c-UeC2tfU/Td_JcTUEtHI/AAAAAAAAAeA/g7OpHEEeQ0I/s400/dr-house-usa-camaras-termograficas-amperis.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5611425148784915570" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/-RBfmKt9inmE/Td_C4UQdwZI/AAAAAAAAAdk/rST8UO1zmyI/s1600/gregory-house-camara-termografica-amperis-tei.jpg"&gt;&lt;img style="cursor:pointer; cursor:hand;width: 400px; height: 226px;" src="http://4.bp.blogspot.com/-RBfmKt9inmE/Td_C4UQdwZI/AAAAAAAAAdk/rST8UO1zmyI/s400/gregory-house-camara-termografica-amperis-tei.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5611417933493158290" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/-Q69g-2W31FE/Td_DCdZIitI/AAAAAAAAAds/fKZBYA9rsFM/s1600/house-termografia-cuddy-camaras-termograficas-amperis-tei.jpg"&gt;&lt;img style="cursor:pointer; cursor:hand;width: 400px; height: 226px;" src="http://3.bp.blogspot.com/-Q69g-2W31FE/Td_DCdZIitI/AAAAAAAAAds/fKZBYA9rsFM/s400/house-termografia-cuddy-camaras-termograficas-amperis-tei.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5611418107744127698" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://1.bp.blogspot.com/-xAPDY88pSRA/Td_CsI_zfuI/AAAAAAAAAdc/IR3lFZ1_7Ow/s1600/house-termografia-medica-camaras-termograficas-amperis-tei.jpg" onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}"&gt;&lt;img style="cursor:pointer; cursor:hand;width: 400px; height: 226px;" src="http://1.bp.blogspot.com/-xAPDY88pSRA/Td_CsI_zfuI/AAAAAAAAAdc/IR3lFZ1_7Ow/s400/house-termografia-medica-camaras-termograficas-amperis-tei.jpg" border="0" alt="" id="BLOGGER_PHOTO_ID_5611417724312059618" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-8898238162468417221?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/8898238162468417221/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=8898238162468417221' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8898238162468417221'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8898238162468417221'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2011/05/el-dr-house-trabaja-con-la-camaras.html' title='El Dr. House trabaja con Cámaras Termográficas Amperis TEi'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-03c-UeC2tfU/Td_JcTUEtHI/AAAAAAAAAeA/g7OpHEEeQ0I/s72-c/dr-house-usa-camaras-termograficas-amperis.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-410360399456354763</id><published>2010-03-02T04:06:00.001-08:00</published><updated>2010-03-02T04:11:44.851-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='medidores'/><category scheme='http://www.blogger.com/atom/ns#' term='manuales'/><category scheme='http://www.blogger.com/atom/ns#' term='resistencia'/><category scheme='http://www.blogger.com/atom/ns#' term='aislamiento'/><title type='text'>Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de Operación</title><content type='html'>&lt;div style="width:477px" id="__ss_3314384"&gt;&lt;strong style="display:block;margin:12px 0 4px"&gt;Manual de Operación del Medidor de resistencia de aislamiento Amperis MIC-5000&lt;/strong&gt;&lt;object width="477" height="510"&gt;&lt;param name="movie" value="http://static.slidesharecdn.com/swf/ssplayerd.swf?doc=mic-5000-amperis-100302054836-phpapp01&amp;amp;stripped_title=medidor-de-resistencia-de-aislamiento-amperis-mic5000-manual-de-operacin"&gt;&lt;param name="allowFullScreen" value="true"&gt;&lt;param name="allowScriptAccess" value="always"&gt;&lt;embed src="http://static.slidesharecdn.com/swf/ssplayerd.swf?doc=mic-5000-amperis-100302054836-phpapp01&amp;amp;stripped_title=medidor-de-resistencia-de-aislamiento-amperis-mic5000-manual-de-operacin" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="477" height="510"&gt;&lt;/embed&gt;&lt;/object&gt;&lt;div style="padding:5px 0 12px"&gt;Ver características completas de este &lt;a href="http://www.amperis.com/productos/megohmetros/mic-5000/"&gt;medidor de resistencia de aislamiento&lt;/a&gt; en Amperis.&lt;/div&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-410360399456354763?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/410360399456354763/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=410360399456354763' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/410360399456354763'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/410360399456354763'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2010/03/medidor-de-resistencia-de-aislamiento.html' title='Medidor de resistencia de aislamiento Amperis MIC-5000 - Manual de Operación'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-9075325777490471142</id><published>2010-01-07T23:23:00.000-08:00</published><updated>2010-01-07T23:25:46.385-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='medidor de rigidez'/><category scheme='http://www.blogger.com/atom/ns#' term='chispometro'/><category scheme='http://www.blogger.com/atom/ns#' term='aceite dieléctrico'/><title type='text'>Medidor de rigidez dieléctrica (chispómetro)</title><content type='html'>&lt;p&gt;&lt;em&gt;Análisis de Gases Disueltos, predicción, purificación y cambiado&lt;br /&gt;&lt;br /&gt;&lt;/em&gt;&lt;br /&gt; Los sistemas de energía y los transformadores son equipos esenciales, por tanto, su fiabilidad y el funcionamiento seguro es importante para determinar sus condiciones de operación, y la industria utiliza pruebas de control de calidad en el diseño de transformadores llenos de aceite. Por lo tanto el empleo de &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;medidores de rigidez dieléctrica&lt;/a&gt; o &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;chispómetros&lt;/a&gt; es fundamental. El efecto del envejecimiento, las propiedades de aceite para transformadores (físicas, químicas y eléctricas) se estudió empleando los métodos internacionales de análisis para la evaluación de la calidad del aceite del transformador. El estudio se llevó a cabo en seis transformadores operando en campo y con períodos de seguimiento de más de veinte años. Se especificaron las propiedades que son fuertemente dependientes del tiempo, y se definieron aquellas que tienen un gran impacto en la acidez del aceite del transformador, la tensión de ruptura y de análisis de gases disueltos. Varias pruebas en el aceite de los transformadores fueron estudiadas para conocer el tiempo de purificación o su modificación, por otra parte, la predicción de las características de bajo diferentes condiciones de operación.&lt;/p&gt;&lt;h3&gt;&lt;strong&gt;I. INTRODUCCIÓN&lt;/strong&gt;&lt;/h3&gt;&lt;p&gt;Los transformadores de potencia son equipos muy importantes de alto costo utilizados en la transmisión y la distribución de la electricidad. Su óptimo rendimiento es importante para los sistemas de operación eléctrica, ya que la pérdida de una unidad crítica puede generar un gran impacto en la seguridad, la fiabilidad y el coste del suministro de la energía eléctrica.&lt;br /&gt;&lt;br /&gt; Los transformadores de energía eléctrica se utilizan para aumentar o disminuir la tensión y son un componente clave en cualquier red de distribución eficiente de energía. Un transformador típico incorpora bobinas de hilo conductor envuelto alrededor de un núcleo y cubierto con soporte de papel aislante. Parte esencial del funcionamiento de estos equipos son los &lt;strong&gt;aceites de transformadores&lt;/strong&gt;, que sirven para dos funciones: El aislamiento eléctrico y la disipación de calor.&lt;/p&gt;&lt;p&gt;Lamentablemente, hay ocasiones en las que los transformadores fallan, lo que supone altos costes para el proveedor de energía y, en casos extremos, posibles explosiones, con la consiguiente amenaza para los trabajadores por lesiones graves, e impactos medioambientales significativos. Los transformadores de potencia se encuentran entre los elementos más valiosos e importantes de los sistemas de energía eléctrica. El envejecimiento del sistema de aislamiento reduce tanto la resistencia mecánica como la fuerza dieléctrica del transformador. Un transformador envejecido está sujeto a defectos que se traducen en altas fuerzas radiales y de compresión.&lt;/p&gt;&lt;p&gt;En un fallo en un transformador envejecido, el aislamiento del conductor normalmente se deteriora hasta el punto en que ya no puede sostener los esfuerzos mecánicos causados por el fallo. La vida/edad del transformador está comúnmente relacionada a la degradación del aislamiento, causado principalmente por la tensión térmica de los aislantes de papel, junto con la descomposición electroquímica de éste. La vida conocida de un transformador la basamos en un parámetro diseñado con respecto a la operación normal y las condiciones climáticas. El envejecimiento no sólo depende de la carga, sino también del tipo de papel, la composición de la pulpa, la humedad y el contenido de oxígeno, así como el nivel de acidez del líquido aislante.&lt;/p&gt;&lt;p&gt;El aislamiento es el componente principal, que desempeña un papel importante en la esperanza de vida del transformador. El aceite sufre un continuo deterioro y degradación debido a la aplicación sostenida de las tensiones térmicas de la electricidad, el ciclo de la carga termal y las condiciones climáticas. Esto puede ser peligroso para el equipo eléctrico y la instalación. La vigilancia continua de las características de aislamiento del aceite se ha convertido en una tarea importante para evitar el deterioro del aceite bajo condiciones de trabajo. Se han hecho varios esfuerzos en los últimos años para estudiar las propiedades eléctricas, físicas y químicas de los aceites aislantes. El mantenimiento preventivo diario de un transformador de aceite consiste en grabar las lecturas de nivel de aceite, lecturas de la temperatura, la media anual de muestras de aceite y toma de muestras para comprobar las propiedades físicas, químicas y eléctricas. Los análisis de aceite incluyen el peso específico, viscosidad cinemática, punto de inflamación, acidez total, humedad, desintegración de tensión y los gases disueltos. Ese es el monitoreo de la condición de aceite del transformador.&lt;/p&gt;&lt;p&gt;Entre esos esfuerzos hay una característica de los aceites naturales frescos y de edad avanzada. Esta área está todavía abierta a estudiar el efecto del período de servicio en las propiedades del aceite de transformadores. Las distintas pruebas de aceite de los transformadores estudiados nos permiten saber cuándo purificar, cambiar y predecir el envejecimiento en las diferentes condiciones de operación.&lt;/p&gt;&lt;h3&gt;&lt;strong&gt;II. EXPERIMENTACIÓN&lt;/strong&gt;&lt;/h3&gt;&lt;p&gt;El rendimiento fiable de aceite mineral aislante en un sistema de aislamiento depende de ciertas características del aceite base, que pueden afectar al rendimiento global del equipo eléctrico. Para llevar a cabo sus múltiples funciones dieléctricas, transferencia de calor y de arco el aceite, deben poseer la creación de las propiedades básicas. El aceite en servicio varía ampliamente en el grado de degradación y el grado de contaminación. El aceite mineral en servicio está sujeto a alteraciones debidas a las condiciones de uso. En muchas aplicaciones, el aceite aislante está en contacto con el aire y por lo tanto sujeto a reacciones de oxidación acelerada por altas temperaturas y presencia de metales, compuestos metálicos, compuestos orgánico-metálicos o de ambos en calidad de agentes oxidantes.&lt;/p&gt;&lt;p&gt;Hay un gran número de pruebas que pueden aplicarse al aceite entregados junto con el equipo o el aceite de aparatos en servicio, pero las siguientes pruebas se cree que son suficientes para determinar si el estado del aceite es el adecuado para la operación continua y sugerir el tipo de acción correctora necesaria. En general no existe sólo un examen como único criterio de la condición de la muestra de aceite.&lt;/p&gt;&lt;p&gt;La evaluación de la condición preferiblemente debe basarse en la evaluación de compuestos de características significativas determinados en laboratorios debidamente equipados. Las pruebas experimentales se llevan a cabo en los transformadores de aceite para determinar experimentalmente sus propiedades eléctricas, físicas y químicas. Las pruebas explicadas se llevaron a cabo en Central Laboratories, Egyptian Electricity Holding Company, Ministry of Electricity and Energy. Seis transformadores con muestras de aceite de prueba para estudiar las características del tiempo de vida del aceite. Se tomaron muestras de aceite de los diferentes transformadores. Estos transformadores operaron en la estación de energía Cairo sur. Las muestras fueron tomadas de transformadores operando durante varios años, con diferentes cargas y condiciones de operación.&lt;/p&gt;&lt;p&gt;Las pruebas llevadas a cabo en el aceite del transformador incluyeron: la tensión de ruptura, acidez total, punto de inflamación, densidad y viscosidad cinemática.&lt;br /&gt;&lt;br /&gt; Los diferentes casos de aceite de los transformadores utilizados en los ensayos fueron:&lt;/p&gt;&lt;ul&gt;&lt;br /&gt; &lt;li&gt;El aceite de transformador de los transformadores (1 y 5) está &lt;strong&gt;nuevo&lt;/strong&gt; (fresco).&lt;/li&gt;&lt;br /&gt; &lt;li&gt;El aceite de transformador de los transformadores (3 y 6) está &lt;strong&gt;purificado&lt;/strong&gt;.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;El aceite de transformador de los transformadores (2 y 4) está &lt;strong&gt;cambiado&lt;/strong&gt;&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;p&gt;Las clasificaciones de estos transformadores, como se muestra en el cuadro (1). Los efectos de las propiedades físicas, químicas y eléctricas de aceite del transformador se estudiaron utilizando los métodos internacionales de análisis para la evaluación de la calidad del aceite del transformador.&lt;/p&gt;&lt;p&gt;La determinación de la tensión de ruptura de cada muestra de aceite del transformador se llevó a cabo de acuerdo con el procedimiento de prueba IEC 156. La acidez total para una muestra de aceite, que figura en (mg KOH / g de aceite), se determinó de acuerdo con el procedimiento previsto en IP 139/64. El punto de inflamación de la muestra de aceite del transformador se llevó a cabo de acuerdo con la norma ASTM D92. El procedimiento de análisis para determinar la viscosidad del aceite del transformador (mm ² / s) se da en la referencia, ASTM D445.&lt;/p&gt;&lt;p&gt;La gravedad específica determinó la norma ASTM 1298. Existen varios métodos de interpretación de análisis de gases disueltos (DGA) en los transformadores en servicio están previstas en la norma CEI 60599, [la Guía IEEE C57.104].&lt;/p&gt;&lt;h3&gt;&lt;strong&gt;III. RESULTADOS EXPERIMENTALES Y DISCUSIÓN&lt;/strong&gt;&lt;/h3&gt;&lt;p&gt;El aceite de los transformadores envejece rápidamente a altas temperaturas y la humedad actúa como un catalizador para su envejecimiento. Hay también otros catalizadores presentes en un transformador que son responsables de la degradación del aceite. Estos incluyen el cobre, pintura, barniz y oxígeno. El principal mecanismo de envejecimiento de aceite del transformador es la oxidación, lo que da lugar a ácidos y formación de otros compuestos polares. Estos productos de oxidación tendrán un efecto perjudicial sobre el estudio de los procesos de degradación. El aceite de transformador, cuando se somete a esfuerzos térmicos y eléctricos en una atmósfera oxidante, va perdiendo su estabilidad y se descompone, se oxida, aumenta su acidez y, finalmente, comienza a producir barro. Este es el mecanismo de degradación del aceite. De hecho, los mecanismos de envejecimiento del aceite son complicados.&lt;/p&gt;&lt;p&gt;En general, el oxígeno reacciona con ciertos hidrocarburos por un proceso de radicales libres, lo que genera hidroperóxidos. Los hidroperóxidos no son estables y se descomponen para formar cetonas y agua. La presencia de grupos de hidroxilo se traducirá en la producción de alcoholes y fenoles. La mayoría de los productos de oxidación tendrán un efecto negativo en las propiedades eléctricas del aceite. Los ácidos carboxílicos que se producen serán disueltos en el aceite o evaporados. Los ácidos disueltos pueden provocar daños en el papel y las bobinas de cobre, mientras que los ácidos evaporados corroen la parte superior de la unidad. Como resultado, se dan las condiciones necesarias para la degradación del aceite. Una parte importante de la degradación del aceite proviene más por el aire en contacto con el aceite caliente en el aparato, que por los resultados de la oxidación en la degradación del aceite. La celulosa en caliente es también una fuente de oxígeno.&lt;/p&gt;&lt;p&gt;Las pruebas experimentales se realizan en aceite de transformadores para aclarar experimentalmente sus propiedades eléctricas, físicas y químicas. Las pruebas llevadas a cabo en el aceite del transformador incluyeron: la tensión de ruptura, acidez total, punto de inflamación, densidad y viscosidad cinemática.&lt;/p&gt;&lt;p&gt;La tensión de ruptura aumentó en el primer período y luego disminuyó con largos períodos de tiempo. En condiciones normales de funcionamiento, la tensión de ruptura será mínima por la oxidación y la contaminación. La contaminación se encuentra comúnmente en aceites de transformadores que contienen agua y partículas, estos contaminantes reducen las cualidades aislantes de aceite del transformador.&lt;/p&gt;&lt;p&gt;La disminución de la tensión de ruptura debida a largos períodos en servicio incrementa algunas partículas impuras, esto aumentará la humedad y el aceite se convertirá en no homogéneo, en consecuencia, disminuye la resistencia al aceite del transformador, que reducirá el valor máximo de la tensión de ruptura del aceite del transformador. Las descargas silenciosas y los flujos de corriente concentrada llevan a la formación de agua, ácidos e hidrógeno. Las descargas de arcos y los líquidos fomentan la producción de partículas de carbono, cera y gases como el monóxido de carbono, dióxido de carbono, acetileno y ácidos, debido a la oxidación y las descargas, hierro y cobre en el líquido, que conducen a la reducción de la resistencia eléctrica.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Información relacionada: &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;Medidor de rigidez dieléctrica&lt;/a&gt; - Chispómetro Portatest de Amperis&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-9075325777490471142?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/9075325777490471142/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=9075325777490471142' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/9075325777490471142'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/9075325777490471142'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2010/01/medidor-de-rigidez-dielectrica.html' title='Medidor de rigidez dieléctrica (chispómetro)'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-7378784848700803316</id><published>2009-10-25T08:04:00.000-07:00</published><updated>2009-10-25T08:06:23.546-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='descargador baterias'/><category scheme='http://www.blogger.com/atom/ns#' term='baterias'/><title type='text'>Probar la eficiencia de baterías industriales - Descargador de baterias</title><content type='html'>&lt;p&gt;Este equipo puede ser programado para descargar la batería a una corriente constante.&lt;/p&gt;&lt;p&gt;El descargador de baterias BDX es muy sencillo de usar y no requiere una formación específica. La programación de las pruebas requiere menos de dos minutos y la operación es completamente automática.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Características principales&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;El equipo protege contra la inversión de polaridad y antiarco (sin fusibles). Se previene la formación de arcos eléctricos con un circuito activo cuando la batería está siendo conectada. Si la batería se conecta con la polaridad cambiada el descargador no inicia el ensayo y la corriente no fluye.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Registrador integrado&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;No es necesario que un PC permanezca conectado al descargador mientras se desarrolla la descarga , porque el registrador (datalogger) tiene suficiente memoria para guardar &lt;strong&gt;la curva de descarga completa&lt;/strong&gt;. Al finalizar la prueba es posible descargar los datos del BDX al PC en segundos. Las conexiones estándar son RS-232 y USB (bajo pedido). También se pueden incluir inferfaces inalámbricos.&lt;/p&gt;&lt;p&gt;El software TrendCom extiende la capacidad de análisis del descargador de baterias. Al ser un potente software que aumenta las capacidades del BDX, permitiendo generar diferentes gráficos de la curva de descarga, como:&lt;/p&gt;&lt;ul&gt;&lt;br /&gt;&lt;li&gt;Potencia de la descarga.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Tensión de la batería.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Corriente de descarga.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Capacidad descargada.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Energía descargada.&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Están disponibles muchas funciones que son muy fáciles de usar, por ejemplo, es posible generar informes de prueba con &lt;strong&gt;gráficos y comentarios&lt;/strong&gt;, para &lt;strong&gt;exportar los datos&lt;/strong&gt; de la prueba a &lt;strong&gt;hojas de cálculo externas&lt;/strong&gt; (compatibles con MS Excel, Open Office, CALC, entre otras) ; exportar un ensayo completo y enviarlo directamente por correo electrónico, etc, etc&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Operación de varias unidades en paralelo (sin límite)&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Cuando uno o más equipos descargador operan en paralelo es posible exportar todos los datos a &lt;em&gt;TrendCom&lt;/em&gt; y fusionarlos en un &lt;strong&gt;único y completo informe&lt;/strong&gt; de prueba. Esta característica ofrece la oportunidad de alcanzar un ilimitado poder de descarga, conectando un ilimitado número de unidades BDX en paralelo.&lt;/p&gt;&lt;p&gt;Cuenta, además, con &lt;strong&gt;protección de temperatura&lt;/strong&gt; de todos los elementos de potencia y del banco de resistencias. En caso de sobrecalentamiento interno (por ejemplo ventiladores bloqueados, circuito de aire obstruido, etc) el descargador suspende el funcionamiento automáticamente.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Doble envolvente para máximo aislamiento térmico&lt;/strong&gt;. Durante la operación las partes externas de la envolvente permanecen frías (la elevación de la temperatura máxima es de 10ºC) para una mayor seguridad del operario.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;Sepa más sobre este imprescindible equipo descargador de baterias en Amperis Products&lt;br /&gt;&lt;br /&gt;&lt;a href="http://www.amperis.com/productos/miscelanea/descargadores-baterias/"&gt;Descargador de baterias Amperis BDX&lt;/a&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-7378784848700803316?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/7378784848700803316/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=7378784848700803316' title='1 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/7378784848700803316'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/7378784848700803316'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2009/10/probar-la-eficiencia-de-baterias.html' title='Probar la eficiencia de baterías industriales - Descargador de baterias'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-804500286325312699</id><published>2009-10-08T02:00:00.000-07:00</published><updated>2009-10-08T04:01:59.873-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='medidor de rigidez'/><category scheme='http://www.blogger.com/atom/ns#' term='tension de ruptura'/><category scheme='http://www.blogger.com/atom/ns#' term='tensión'/><category scheme='http://www.blogger.com/atom/ns#' term='medidor de tensión'/><category scheme='http://www.blogger.com/atom/ns#' term='chispometro'/><category scheme='http://www.blogger.com/atom/ns#' term='ruptura'/><category scheme='http://www.blogger.com/atom/ns#' term='aceite dieléctrico'/><title type='text'>Voltaje de ruptura en aceite - Chispómetro Portatest</title><content type='html'>&lt;p&gt;&lt;strong&gt;El voltaje de ruptura en aceite aislante baja las influencias de la humedad, acidez, partículas y presión.&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; El voltaje de ruptura de un aceite mineral aislante fue investigado bajo las influencias de humedad, acidez, presión y partículas, Los estándares IEC156/95 (VDE0370/Part5/96 y ASTM D1816) especificaban las condiciones de la prueba. La humedad provee cargadores de carga, por lo tanto una saturación de humedad de 0 a 20% decrece el voltaje de ruptura de 72 a 61 kV.&lt;br /&gt;&lt;br /&gt; El ácido como producto deteriorante también reduce la fuerza dieléctrica por la misma razón. No el número total de acido NTA, pero a menor efecto de ácidos moleculares, mayor será el decrecimiento. Desde que el proceso de ruptura se inicia con una burbuja microscópica, y una presión en incremento; incrementa también el voltaje de ruptura. La observación del comportamiento asintótico parece llegar a un máximo valor final en el voltaje de ruptura alrededor de 150 kV. Bajo inflación apoya la generación de burbujas, reduciendo el soporte de la fuerza dieléctrica. Las partículas secas (fibra celulosa) reducen el voltaje de ruptura sólo bajo inflación, casi ninguna influencia fue observada en presión atmosférica.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; Aceite mineral, ruptura, partículas, acidez, humedad, presión&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; 1 Ruptura en aceite aislante&lt;/p&gt;&lt;ol&gt;  &lt;li&gt;Introducción&lt;/li&gt;&lt;/ol&gt;&lt;br /&gt;&lt;p&gt;El aceite aislante en transformadores de potencia sirve como un medio transmisor de calor y como un aislante liquido, dos razones que motivaron la investigación de sus propiedades de aislamiento: Primeramente los transformadores de potencia son usualmente operados bajo condiciones de envejecimiento. Así el contenido de humedad en el aceite incrementa, los productos de envejecimiento o deterioro se disuelven y las partículas se dispersan. En segundo lugar, los transformadores son operados bajo nuevas condiciones ambientales, donde se producen bajas y altas de presión. El servicio de seguridad y mantenimiento necesita una investigación meticulosa de estas influencias.&lt;/p&gt;&lt;ol&gt;  &lt;li&gt;Consideraciones Teóricas&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;Los líquidos aislantes derivan su fuerza dieléctrica desde la más alta densidad comparada con los gases. El proceso de ruptura comienza con una burbuja microscópica, un área de largas distancias entre corpúsculos, donde los iones y electrones pueden iniciar avalanchas. Estas burbujas microscópicas son originadas por impulsos de corriente en un electrodo. El siguiente impulso de corriente inyecta portadores de carga en la burbuja, conduciendo la amplificación de corriente y finalmente a la ruptura [1]. A partir de estas consideraciones, se espera lo siguiente:&lt;/p&gt;&lt;ol&gt;&lt;br /&gt; &lt;li&gt;La humedad conduce a los portadores de cargas y por lo tanto disminuye el soporte de la fuerza dieléctrica. &lt;/li&gt;&lt;br /&gt; &lt;li&gt;Oxidamiento por productos tales como el ácido también llevan a los transportadores de carga a través de la disociación. Adicionalmente éstos son activos en la superficie, disminuyendo la tensión superficial. Así mantienen la evolución de la burbuja siguiendo un decrecimiento de la fuerza dieléctrica.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;La presión también ejerce influencia en la evolución de la burbuja. Con un incremento de presión, el voltaje de ruptura debería incrementar. Para presiones debajo de la presión atmosférica el voltaje de ruptura debería reducirse.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;Las partículas se moverán en áreas de gran tensión dependiendo de sus permitividad en relación a la del aceite. Se espera una disminución en el voltaje de ruptura si son altamente conductoras o húmedas.&lt;/li&gt;&lt;/ol&gt;&lt;ol&gt;&lt;br /&gt; &lt;li&gt;Influencia de humedad y acidez&lt;br /&gt;   &lt;ol&gt;&lt;br /&gt;     &lt;li&gt; Dispositivo de medición&lt;/li&gt;&lt;/ol&gt;&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;Un sistema de prueba dieléctrica convencional, Portatest midió el voltaje de ruptura a diferente contenido de humedad y acidez. El sistema funciona completamente automatizado, lo que es muy conveniente para períodos largos de prueba. La ventaja especial es una rápida detección de la ruptura y la desconexión de la corriente en menos de 1ms, que junto con una baja de energía en el circuito de prueba previene la carbonatación del aceite mineral, incluso cientos de exámenes en la misma muestra de aceite no redujeron el voltaje de ruptura debido a los productos de combustión.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; &lt;img src="http://www.amperis.com/images/articulos/analizador-aceite-transformadores-portatest.jpg" width="335" height="256" alt="Voltaje de ruptura en aceite - Chispómetro Portatest" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 1: Un &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;equipo de prueba automático de líquidos aislantes Portatest&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; Los exámenes fueron llevados a cabo de acuerdo al IEC156/95 Figura II (VDE0370/Teil5/96 y ASTM D1816), i.e. electrodos esféricos con un radio de 25mm. La figura 1 muestra el sistema de pruebas automático. Un sistema automático de valoración potenciométrica “Titrino SM 702 con unidad de intercambio 806” hecho por Metrohm midió la acidez de los aceites (Figura 2). Aquí el Número Total de Acido NTA fue determinado por una valoración volumétrica con potasa para neutralizar los ácidos carboxílicos.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; &lt;img src="http://www.amperis.com/images/articulos/fig2-aceite.jpg" alt="Voltaje de ruptura, Chispómetro Portatest" width="155" height="229" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 2&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; La humedad de los aceites fue determinada como la humedad contenida relativa a la saturación (RS en %) por sensores capacitivos Vaisala HMP 228. En orden de obtener resultados dependientes, los sensores fueron cuidadosamente calibrados por soluciones saturadas de sal con cloruro de litio y cloruro de sodio. El contenido de humedad relativo a la saturación (%) brinda más información sobre los efectos cruciales de la humedad en el voltaje de ruptura que el uso convencional del contenido de humedad relativo al peso en ppm. Por lo tanto fue controlado para medir la humedad en ppm. No obstante este valor puede ser calculado por isotermas de adsorción como fue publicado en [2].&lt;/p&gt;&lt;ol&gt;  &lt;li&gt;Aceites aislantes investigados&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;Nuevo tipo de aceite aislante mineral tipo Nynas Nytro 3000 y servicio de desgaste Shell K 6 SX de 1964 fueron investigados. Ambos aceites estaban libres de partículas y saturados de gas, la temperatura era de 20-21ºC. Con el fin de obtener aceites con acidez variada ambos aceites fueron mezclados en seis pasos, ver la siguiente tabla y los resultados de la valoración del acido en Figura 3. Radio del acido total de Nynas a Shell.&lt;br /&gt;&lt;br /&gt; &lt;img src="http://www.amperis.com/images/articulos/resultados-determinacion-NTA-chispometro-portatest.jpg" width="458" height="312" alt="Resultados de la determinación del NTA - Voltaje de ruptura en aceite - Chispómetro Portatest" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 3: Resultados de la determinación del NTA en los seis aceites aislantes investigados&lt;/p&gt;&lt;p&gt; Investigar la influencia en una baja molecular de ácidos carboxílicos, ácido fórmico HCOOH, el cual también es un producto deteriorante, fue agregado al nuevo Nynas Nytro 3000.&lt;br /&gt;&lt;br /&gt; Esto resulto en un NTA de 0,27. La humedad de los aceites investigados fue variada en cuatro pasos: 0-5-10-20% de la saturación relativa de humedad. Esto cubre un rango típico de transformadores de poder. Para obtener varios contenidos de humedad, cada uno de los seis aceites fue establecido por la inmersión de la celulosa, De acuerdo al equilibrio termodinámico y las capacidades de adsorción de la humedad, la saturación relativa de la celulosa determina la saturación relativa del aceite [2].&lt;br /&gt;&lt;br /&gt; Ejemplos para obtención de 10% de saturación de humedad relativa en aceite, papel aislante con 10% de saturación de humedad relativa fue agregado. Ciclos de calor subsecuentemente afectan una difusión rápida y homogénea de la distribución de la humedad.&lt;/p&gt;&lt;ol&gt;&lt;br /&gt; &lt;li&gt;Resultados y discusión.&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;Un gran dispersamiento de los resultados significa la medida del voltaje de ruptura. Los primeros 40-100 pruebas de ruptura fueron significativamente más bajos que el anterior valor alcanzado. Esto puede ser explicado por partículas en el aceite y en los electrodos. La figura 3 ilustra dicho fenómeno.&lt;br /&gt;&lt;br /&gt; Número de mediciones&lt;br /&gt;&lt;br /&gt; Ruptura del voltaje/kV-&lt;br /&gt;&lt;br /&gt; &lt;img src="http://www.amperis.com/images/articulos/esparcimiento-voltaje-ruptura-chispometro-portatest.jpg" alt="Resultados de la determinación del NTA - Chispómetro Portatest" width="488" height="345" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 4: Esparcimiento del voltaje de ruptura&lt;br /&gt;&lt;br /&gt;&lt;br /&gt; Figura 5 representa el voltaje de ruptura en aceite mineral como una función de la saturación de humedad relativa y número total del acido. Cada punto de medición es el promedio de alrededor de 150 rupturas únicas, considerando que los primeros resultados con la enorme dispersión fueran rechazados. La saturación relativa de humedad/ % del voltaje de ruptura / kV&lt;br /&gt;&lt;br /&gt; &lt;img src="http://www.amperis.com/images/articulos/voltaje-ruptura-aceite-mineral-chispometro-portatest.jpg" alt="Chispómetro Portatest graficos, voltaje de ruptura en aceite mineral, función de saturación de humedad relativa y un número total de acido" width="470" height="335" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 5: El voltaje de ruptura en aceite mineral como una función de la saturación de humedad relativa y un número total de acido&lt;/p&gt;&lt;p&gt;Es evidente, que con el incremento de la saturación de humedad relativa desde 0 a 20% el voltaje de ruptura para nuevo aceite se reduce desde 72 a 61 kV. Con el acido en incremento (NTA) desde 0,01 a 0,49 y una saturación constante relativa de 0% el voltaje de ruptura se reduce de, 72 kV a 61 kV.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/influencia-acido-molecular-chispometro-portatest.jpg" alt="influencia de bajo acido molecular disuelto en el chispometro portatest" width="421" height="250" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 6 muestra la influencia de bajo acido molecular disuelto adicionalmente comparado a un nuevo y a un aceite de servicio deteriorante. La saturación de la humedad relativa in todos los aceites fue de 10%. Aquí el acido fórmico fue agregado a un nuevo Nynas Nytro 3000, conduciendo a un NTA de 0,27.&lt;/p&gt;&lt;p&gt; Debido a la fuerza del acido en el voltaje de ruptura se reduce a un 38,7 kV, el cual es mucho menor que el del aceite de servicio deteriorante, aunque la acidez de este último es mayor con 0,49. Uno puede concluir, que no el número total de acido, pero más bien el bajo acido molecular contribuye a la reducción del voltaje de ruptura. Esto tiene que ser considerado cuando se comparan esos resultados con otros.&lt;/p&gt;&lt;ol&gt;&lt;br /&gt; &lt;li&gt;Influencia de presión y partículas&lt;br /&gt;   &lt;ol&gt;&lt;br /&gt;     &lt;li&gt; Dispositivo de medición &lt;/li&gt;&lt;/ol&gt;&lt;/li&gt;&lt;/ol&gt;&lt;br /&gt;&lt;p&gt;El voltaje de ruptura de aceite aislante fue medido con tres diferentes dispositivos de prueba para tres rangos de presión. Para una presión de aceite de 1-21 barras y para 1-100 barras dos celdas especiales de medición fueron construidas. El sistema de pruebas automatizada de Portatest con una medida de celda modificada a la presión del aceite de 0,1-1,5 barras. En este contexto la presión de una barra es igual a la presión atmosférica o estándar. Figura 7 muestra el dispositivo de medición para 1-21 barras de presión de aceite. Un transformador de alto voltaje genera la prueba de voltaje AC, el cual es conectado sobre resistencias protectoras con la celda de medición. En la conexión a tierra en la celda de una investigación actual observa la corriente del cortocircuito.&lt;br /&gt;&lt;br /&gt; &lt;img src="http://www.amperis.com/images/articulos/barras-presion-aceite-chispometro-portatest.jpg" alt="Dispositivo para barras de presión de aceite en chispometro portatest" width="512" height="259" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 7: Dispositivo para 1-21 barras de presión de aceite.&lt;/p&gt;&lt;p&gt; Una celda de prueba para la sobrepresión fue construida hecha de resina epoxi. El volumen del aceite ascendía 1,1l. Los electrodos son hechos de acero inoxidable con una forma de acuerdo a EN 60156/ VDE 0370 T.5 (tipo seta o esférica con un radio de 25mm) y un espacio de 2,5 mm. La presión muy alta de hasta 100 barras requiere una segunda celda de prueba. Aquí fueron usados electrodos hechos de aleaciones de bronce. La figura 8 muestra la celda de prueba y los electrodos.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/celda-prueba-chispometro-portatest.jpg" alt="Celda de prueba y electrodos para presión de aceite 1-100 barras en el equipo portatest" width="500" height="326" /&gt;&lt;/p&gt;&lt;p&gt;Figura 8: Celda de prueba y electrodos para presión de aceite 1-100 barras&lt;/p&gt;&lt;br /&gt;&lt;p&gt; Un convencional AC el transformador de prueba generó el voltaje de prueba. Un divisor de tensión capacitivo junto con un osciloscopio digital midió el voltaje de ruptura.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/diagrama-circuito-chispometro-portatest.jpg" alt="Diagrama de circuito para las investigaciones con chispometro portatest" width="484" height="240" /&gt;&lt;br /&gt; Figura 9: Diagrama de circuito para las investigaciones a 1-100 barras&lt;/p&gt;&lt;br /&gt;&lt;p&gt;Para las pruebas de rupturas de líquidos es muy importante limitar la corriente del cortocircuito, ya que las partículas de aceite que hacen combustión influenciaran los resultados de las pruebas. Lo siguiente significa disminuir este error potencial.&lt;/p&gt;&lt;ol&gt;&lt;br /&gt; &lt;li&gt;Una serie de resistencias Rp al lado LV del transformador HV teniendo 5 Ohms reduce la corriente.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;Una serie de resistencias Rp al lado HV teniendo 1 MOhm amortiguando adicionalmente.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;Un circuito electrónico detecta la ruptura por componentes de alta frecuencia en el voltaje y la corriente. En consecuencia el arco eléctrico se extingue en las próximas 30ms después de la ruptura. La carga eléctrica por ruptura es menos que 800 µC. Para el rango de presión menor de 0,1-1,5 barras el sistema automático de prueba como fue descrito en la sección 2.1 fue usado. La medida original de su celda se volvió a prueba de presión por una nueva tapa con conexiones a una bomba de vacio y un manómetro, ver la figura 10.&lt;br /&gt;&lt;br /&gt;   &lt;img src="http://www.amperis.com/images/articulos/sistema-prueba-automatico-chispometro-portatest.jpg" alt="Sistema de prueba automático Portatest con celdas de medida" width="359" height="269" /&gt;&lt;br /&gt;&lt;br /&gt; &lt;/li&gt;&lt;br /&gt; &lt;li&gt;Figura 10: el sistema de prueba automático Portatest con celdas de medida modificada teniendo aquí 0,3 barras de presión.&lt;br /&gt; &lt;/li&gt;&lt;br /&gt; &lt;ol&gt;&lt;br /&gt;   &lt;li&gt;Aceites aislantes investigados&lt;/li&gt;&lt;/ol&gt;&lt;/ol&gt;&lt;p&gt;Los nuevos aceites minerales aislantes tipo Nynas Nytro 3000 (no inhibido) y Nynas Nytro 3000 X (inhibido) fueron investigados.&lt;br /&gt;&lt;br /&gt; Ambos aceites estaban libres de partículas y gas saturado. Desgasificación con un secado convencional y la planta de desgasificación mostro que no había influencia durante el voltaje de ruptura. La saturación de la humedad relativa fue 4-6%, la temperatura 20-22ºC. Para investigar la influencia de partículas, fibras de cartón prensado seco fueron dispersadas en una concentración de 20 t 75 g/t aceite.&lt;/p&gt;&lt;ol&gt;  &lt;li&gt;Resultados y discusión&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/grafico-aceite-transformadores-portatest.jpg" alt="voltaje y corriente durante una ruptura" width="483" height="226" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 11 muestra ejemplar de voltaje y corriente durante una ruptura en la configuración para las investigaciones de 100 barras.&lt;/p&gt;&lt;p&gt;La figura izquierda muestra el voltaje, la derecha la corriente con una escala de 1 V=1 A. Figura 11: Voltaje (izquierda) y corriente de una ruptura a 1 barra.&lt;/p&gt;&lt;p&gt;Figura 12 muestra el &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;voltaje de ruptura del aceite&lt;/a&gt; aislante como una función de presión con escala lineal del eje x.&lt;br /&gt;&lt;br /&gt; Este diagrama combina los resultados de todos los tres dispositivos de medición usados para las investigaciones de presión. El número de las rupturas únicas por cada punto de medida fue 200-420 para el rango de presión bajo 1 barra y 75 para el rango de presión sobre 1 barra. Los resultados muestran una derivación considerable del estándar causada por naturaleza estocástica del proceso de ruptura, pero un pequeño 5%, del cinturón de confianza.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/eje-x-chispometro.jpg" alt="voltaje de ruptura de un aceite aislante como una función de presión" width="471" height="358" /&gt;&lt;br /&gt; Figura 12: el voltaje de ruptura de un aceite aislante como una función de presión con una escala lineal en el eje x.&lt;/p&gt;&lt;p&gt;Solo como la teoría deja que uno asuma, un aumento de presión en el aceite causa un incremento en el voltaje de ruptura hasta un valor asintótico final. El proceso de ruptura comienza en burbujas microscópicas, inducido por la inyección de corriente [1]. Una alta presión obstaculiza la evolución de la burbuja. Por otro lado bajo inflación la apoya. Resultando en un valor de ruptura descendiente. En la figura 13 permite para una mejor vista de la baja del rango de presión debido a su escala logarítmica en el eje x.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/voltaje-ruptura-aceite-chispometro-portatest.jpg" alt="voltaje de ruptura del aceite aislante como una función de presión con una escala logarítmica del eje x" width="488" height="351" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 13: el voltaje de ruptura del aceite aislante como una función de presión con una escala logarítmica del eje x.&lt;/p&gt;&lt;p&gt; El aceite inhibido tiene solo una pequeña influencia en el voltaje de ruptura. El valor máximo asintótico para el aceite desinhibido parece estar alrededor de 140 kV, considerando que el aceite inhibido viniera cerca de los 150 kV.&lt;br /&gt;&lt;br /&gt; Figura 14 muestra, como las partículas secas de celulosa influencian el voltaje de ruptura en un nuevo aceite. Para el rango bajo de presión hay una reducción, pero para la presión atmosférica y sobre la influencia y solamente pequeña, La razón para la influencian que las partículas permiten a la burbuja evolucionar. Este efecto claramente visible sucede solo bajo inflamación. Debe ser mencionado, que solo fibras secas celulósicas fueron agregadas, para fibras húmedas la influencia será más dramática.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/particulas-secas-celulosa.jpg" alt="Influencia de partículas secas de celulosa en el voltaje de ruptura en aceite nuevo" width="480" height="303" /&gt;&lt;br /&gt; Figura 14: Influencia de partículas secas de celulosa en el &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;voltaje de ruptura en aceite&lt;/a&gt; nuevo&lt;/p&gt;&lt;p&gt;Durante las medidas en alta presión del aceite un fenómeno fue observado: el aceite recupero su capacidad aislante, la ruptura en aceite desapareció en la siguiente mitad de ciclo de la prueba de voltaje. Estas “rupturas parciales” ocurrieron típicamente a 70-85% del promedio del voltaje de ruptura en una presión especifica de aceite.&lt;br /&gt;&lt;br /&gt; La figura 15 ilustra su comportamiento, por favor ver el contraste con la figura 11, donde una ruptura completa en aceite es representado.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/ruptura-parcial.jpg" alt="El voltaje en la brecha de aceite en una ruptura parcial" width="475" height="325" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 15: El voltaje en la brecha de aceite en una “ruptura parcial”&lt;/p&gt;&lt;p&gt; El radio de las rupturas totales para las “rupturas parciales” depende de la presión de aceite, como mostrado en la figura 16. Bajo presión atmosférica todas las rupturas fueron completas, en 60 barras 80% de las rupturas fueron “parcialmente”. Una explicación posible de la presión dependiente es, que la alta presión apaga el arco eléctrico en la brecha de aceite. Así el aceite recupero su capacidad aislante en algunos milisegundos.&lt;/p&gt;&lt;p&gt;&lt;img src="http://www.amperis.com/images/articulos/presion-aceite-portatest-chispometro.jpg" alt="Radio total de las rupturas parciales" width="382" height="301" /&gt;&lt;br /&gt;&lt;br /&gt; Figura 16: Radio total de las rupturas parciales como una función de la presión del aceite&lt;/p&gt;&lt;ol&gt;&lt;br /&gt; &lt;li&gt;Resumen y conclusiones&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;El voltaje de ruptura en aceite mineral aislante fue investigado bajo las influencias de humedad, acidez, presión y partículas usando electrodos de acuerdo a IEC156/95 Figura II (VDE0370/Teil5/96 y ASTM D1816)&lt;/p&gt;&lt;ol&gt;&lt;br /&gt; &lt;li&gt;El proceso de ruptura comienza con una burbuja microscópica&lt;/li&gt;&lt;br /&gt; &lt;li&gt;La humedad provee cargas eléctricas, por lo tanto una saturación de humedad de 0 a 20% reduce la fuerza dieléctrica de 72 a 61 kV.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;El acido como producto deteriorante reduce la fuerza dieléctrica también por la misma razón.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;No el número total de acido NTA, pero los bajos ácidos moleculares causan mayor efecto.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;Una presión en aumento también incrementa el voltaje de ruptura. El comportamiento asintótico parece llegar a un valor máximo final de alrededor de 150 kV.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;Bajo inflación apoya la generación de burbujas. Reduciendo el soporte de la fuerza dieléctrica.&lt;/li&gt;&lt;br /&gt; &lt;li&gt;Partículas secas (fibras de celulosa) reducen el voltaje de ruptura solo bajo inflación, ya que ellos apoyan la generación de burbujas. Casi no hay influencia bajo presión atmosférica y por encima de ella.&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;Temas relacionados:&lt;br /&gt;&lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;Chispómetro de aceite dieléctrico de transformador&lt;/a&gt; | &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;Chispómetro&lt;/a&gt; | &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;Medidor de tensión de ruptura de aceite dieléctrico&lt;/a&gt; | &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/portatest/"&gt;Medidor de rigidez dieléctrica de aceite&lt;/a&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-804500286325312699?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/804500286325312699/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=804500286325312699' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/804500286325312699'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/804500286325312699'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2009/10/voltaje-de-ruptura-en-aceite.html' title='Voltaje de ruptura en aceite - Chispómetro Portatest'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-8931329530871422903</id><published>2009-06-09T02:44:00.000-07:00</published><updated>2009-06-09T02:57:15.674-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='myrkos'/><category scheme='http://www.blogger.com/atom/ns#' term='aceite'/><category scheme='http://www.blogger.com/atom/ns#' term='transformadores'/><category scheme='http://www.blogger.com/atom/ns#' term='cromatógrafo'/><category scheme='http://www.blogger.com/atom/ns#' term='gases'/><title type='text'>Monitorización de transformadores</title><content type='html'>Amperis introduce en España la más avanzada tecnología para el &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/myrkos/"&gt;analisis de gases disueltos en aceite&lt;/a&gt; de transformadores.&lt;br /&gt;    &lt;p&gt; &lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_liWG2cxeH1g/Si4xDXfIabI/AAAAAAAAAUw/eAv6tT0gAzE/s1600-h/amperis-analisis-gases.gif"&gt;&lt;img style="margin: 0pt 10px 0pt 0pt; cursor: pointer; width: 320px; height: 208px; float: left;" src="http://2.bp.blogspot.com/_liWG2cxeH1g/Si4xDXfIabI/AAAAAAAAAUw/eAv6tT0gAzE/s320/amperis-analisis-gases.gif" alt="analisis de gases disueltos en aceite, Monitorización de transformadores" id="BLOGGER_PHOTO_ID_5345263741649316274" border="0" /&gt;&lt;/a&gt;            &lt;br /&gt;&lt;/p&gt;           &lt;p&gt;El equipo de analisis de gases disueltos en aceite &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/myrkos/"&gt;&lt;strong&gt;Myrkos&lt;/strong&gt;&lt;/a&gt; se usa en conjunto con la jeringa Shake Test® (prueba por agitación) o con una sonda extractora de gases especialmente diseñada para medir por separado los siguientes gases de falla disueltos en el aceite de transformador: hidrógeno, metano, monóxido de carbono, dióxido de carbono, etileno, etano y acetileno.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;La medición en el sitio de gases de falla disueltos en equipos eléctricos llenos de aceite (transformadores, reactores, aisladores de cruce, cortacircuitos, cambiadores de toma carga, etc.) pueden realizarse rápidamente y con precisión con el &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/myrkos/"&gt;Analizador DGA&lt;/a&gt; Myrkos. Se puede realizar un análisis completo de gas en aceite en minutos para detectar los 7 gases de falla.&lt;/p&gt;El Myrkos es esencialmente un &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/myrkos/"&gt;cromatógrafo portátil&lt;/a&gt; de gas muy rápido, optimizado para el análisis de muestras de gas. No está concebido para el análisis directo de líquidos ya que la entrada de cualquier cantidad de líquido causará daños inmediatos e irreversibles a la unidad.&lt;br /&gt;&lt;p&gt;Para poder medir &lt;a href="http://www.amperis.com/productos/pruebas-transformadores/myrkos/"&gt;gases disueltos en aceite&lt;/a&gt;, debe producirse una muestra de gas en la que las concentraciones de fase del gas sean relativas de manera conocida y reproducible con las concentraciones disueltas. El Myrkos está concebido para usarse en conjunto con una sonda extractora de gas o una jeringa Shake Test®, un dispositivo exclusivo para extracción de gas, desarrollado y manufacturado por MSS.&lt;/p&gt;&lt;p&gt;Sepa más sobre este equipo en la web:&lt;br /&gt;&lt;a href="http://www.amperis.com/productos/pruebas-transformadores/myrkos/"&gt;http://www.amperis.com/productos/pruebas-transformadores/myrkos/&lt;/a&gt;&lt;br /&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-8931329530871422903?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/8931329530871422903/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=8931329530871422903' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8931329530871422903'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8931329530871422903'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2009/06/monitorizacion-de-transformadores.html' title='Monitorización de transformadores'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_liWG2cxeH1g/Si4xDXfIabI/AAAAAAAAAUw/eAv6tT0gAzE/s72-c/amperis-analisis-gases.gif' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-985607947130875334</id><published>2009-03-08T14:56:00.000-07:00</published><updated>2009-03-08T14:59:14.987-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='inspección'/><category scheme='http://www.blogger.com/atom/ns#' term='alto voltaje'/><category scheme='http://www.blogger.com/atom/ns#' term='redes eléctricas'/><title type='text'>Mantenimiento de redes electricas de alto voltaje</title><content type='html'>&lt;div&gt;&lt;object width="420" height="339"&gt;&lt;param name="movie" value="http://www.dailymotion.com/swf/x5lpz1" /&gt;&lt;param name="allowFullScreen" value="true" /&gt;&lt;param name="allowScriptAccess" value="always" /&gt;&lt;embed src="http://www.dailymotion.com/swf/x5lpz1" type="application/x-shockwave-flash" width="420" height="339" allowFullScreen="true" allowScriptAccess="always"&gt;&lt;/embed&gt;&lt;/object&gt;&lt;br /&gt;En este impresionante vídeo se muestra como dos operadores inspeccionan cables de alto voltaje&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-985607947130875334?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/985607947130875334/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=985607947130875334' title='1 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/985607947130875334'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/985607947130875334'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2009/03/mantenimiento-de-redes-electricas-de.html' title='Mantenimiento de redes electricas de alto voltaje'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-4742365830033479976</id><published>2009-02-05T10:47:00.000-08:00</published><updated>2009-02-05T11:14:34.246-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='descargas parciales'/><category scheme='http://www.blogger.com/atom/ns#' term='descarga parcial'/><title type='text'>Mejorando la medida de descargas parciales</title><content type='html'>&lt;p&gt;Una descarga parcial es la disipación de la energía causada por la acumulación de intensidad en un campo eléctrico localizado. En los dispositivos de alto voltaje tales como transformadores, esta acumulación de carga y su liberación puede ser síntoma de problemas asociados con el envejecimiento, partículas flotantes y ruptura de aislamiento. Esta es la razón por la que la detección de descargas parciales se utiliza en los sistemas de energía para supervisar el estado de los transformadores de alta tensión.&lt;/p&gt;Si esos problemas no son detectados y reparados, la fuerza y la frecuencia de las descargas parciales aumenta y, finalmente, produce el fallo del transformador, que puede causar daño al equipo externo e incendios, con la consecuente pérdida de ingresos debido a un imprevisto corte de luz. La detección fiable de las descargas parciales en línea es una necesidad fundamental para mejorar la seguridad del personal de las empresas y reducir la pérdida potencial del servicio.&lt;br /&gt;&lt;p&gt;El fenómeno de las descargas parciales se manifiesta en una variedad de señales físicamente observables, incluidos las señales eléctricas y acústicas, y en la actualidad se detectan mediante una gran cantidad de técnicas de medición.&lt;br /&gt; Estas técnicas incluyen transductores piezoeléctricos (PZT), basados en detección acústica. Muchos sistemas modernos utilizan una combinación de estas técnicas porque la detección eléctrica es una disciplina madura y probada, y la detección acústica permite que la señal sea localizada cuando varios sensores están montados en el exterior de la cuba.&lt;/p&gt;Sin embargo, si un sensor acústico puede ser colocado en el interior de la cuba, no sólo la detección acústica será más fácil debido al aumento de la amplitud de la señal y la eliminación de las múltiples interferencias, sino que el posicionamiento también podría llevarse a cabo con más precisión en menos tiempo.&lt;br /&gt;&lt;p&gt;Este artículo presenta un sensor acústico de fibra óptica diseñado para detectar y localizar &lt;a href="http://www.amperis.com/productos/detectores-descargas-parciales/"&gt;descargas parciales&lt;/a&gt; en un transformador de alta tensión. El sistema se basa en un sistema de sensor acústico óptico que es capaz de sobrevivir a las duras condiciones ambientales sin comprometer la funcionalidad del transformador, que permite la detección en línea y posicionamiento.&lt;/p&gt;Este artículo presenta la funcionalidad teórica y validación experimental de un sensor de banda limitada OA en un rango de 100-300 kHz, lo cual coincide con la frecuencia de un pulso acústico causado por una descarga parcial.&lt;br /&gt;&lt;p&gt;También presenta un sistema de posicionamiento utilizando la diferencia de tiempo de llegada (TDOA) del pulso acústico con respecto a los cuatro sensores que es capaz de informar acerca de la posición tridimensional de la descarga parcial con una tolerancia de ± 5 cm en cualquier eje.&lt;/p&gt;Las descargas parciales son interrupciones de corriente causadas por la acumulación de intensidad de campo eléctrico en una región finita. En dispositivos de alta tensión, tales como transformadores, las descargas parciales pueden ser un síntoma de problemas en el dispositivo.&lt;br /&gt;&lt;p&gt;Con el tiempo, se pueden dañar los materiales en el transformador, incluyendo la disolución y el revestimiento de papel de aislamiento de las paredes de la cuba del transformador. Si el daño no es detectado o corregido, los errores pueden provocar que el transformador deje de operar en sus parámetros normales y, finalmente, un fallo de graves consecuencias tendrá lugar, causando daños potenciales en torno a equipos e instalaciones, así como la pérdida de ingresos debido a un imprevisto corte de luz. En un sistema moderno de energía de alta tensión, se utiliza la detección de descargas parciales para supervisar el estado de los transformadores.&lt;/p&gt;Los principales métodos de detección de descargas parciales se basan en observaciones de las características eléctricas y acústicas del fenómeno. Los sistemas de detección acústica de descargas parciales son más ventajosos que los sistemas de vigilancia de transformadores eléctricos, ya que además de la detección, la medición de la señal observada por varios sensores acústicos permite la localización de las descargas parciales.&lt;br /&gt;&lt;p&gt;La información de posición puede ser utilizada por monitores de planta para diagnosticar la causa de la descarga parcial, así como reducir el tiempo de mantenimiento. El problema con los actuales sistemas de detección acústica de descargas parciales es que la señal acústica debe observarse fuera de la cuba del transformador, ya que no existen sensores desarrollados que puedan sobrevivir en el interior de la cuba y ser eléctrica y químicamente neutros. Porque el camino entre la descarga parcial y los sensores acústicos están entre la pared de la cuba, las interferencias pueden limitar gravemente la exactitud de cualquier sistema de posicionamiento.&lt;/p&gt;La interferencia es causada por las diferencias de velocidad de la onda acústica en el aceite mineral y la cuba del transformador. Como el pulso acústico viaja a través de la cuba, se encuentra con la pared en diferentes momentos, y es registrado por el sensor exterior. En el caso de la HVT, la señal llega al sensor antes que a través del aceite, porque la velocidad del sonido en el acero es mucho mayor que en el aceite mineral. Esta diferencia de tiempo de tránsito puede dar lugar a una distorsión de la señal que conduce a un cálculo erróneo TDOA. Por lo tanto, sería una enorme ventaja contar con un sensor diseñado para funcionar dentro dla cuba del transformador sin inhibir o cambiar la funcionalidad del transformador. Una vez que un sensor interno ha sido diseñado, un sistema de posicionamiento debe ser empleado, que hace uso más eficiente en capturar señales acústicas. La ubicación de la fuente de descargas parciales en la cuba del transformador está determinada por medir la diferencia de tiempo de llegada (TDOA) de la señal acústica de cada uno de entre varios sensores de posiciones dentro de la cuba, que luego pueden ser utilizados para resolver un sistema de ecuaciones no lineales.&lt;br /&gt;&lt;p&gt;Este articulo presenta un sistema de sensores ópticos basados en la detección y ubicación acústica. El sensor, un sensor acústico de fibra óptica, está hecho de sílice de forma que es a la vez, tanto química como  eléctricamente neutro, y pueden sobrevivir a las duras condiciones de la cuba, &lt;strong&gt;sin comprometer el interior del transformador o alterar la funcionalidad del dispositivo&lt;/strong&gt;. Esto permite registrar los datos a los sensores para, mientras que el transformador está en línea, a fin de que la HVT pueda ser monitoreada constantemente y sin pérdida de servicio. El sistema también tiene la capacidad de posicionamiento, ya que consta de cuatro sensores, que proporcionan TDOA, tres mediciones y pueden proporcionar la fuente de posición en tres dimensiones con una precisión limitada por un cubo de 10 cm.&lt;/p&gt;El desarrollo de este sistema es importante porque actualmente la detección y localización de descargas parciales en los sistemas son insuficientes para proporcionar resultados fiables en un plazo de tiempo razonable.&lt;br /&gt;&lt;p&gt;En el caso de equipos eléctricos o de detección química, la información de la posición lo es todo, pero es imposible la utilización de estos métodos por sí solos. La detección acústica ofrece la posibilidad de localizar un descargas parciales, pero la precisión de los sistemas actuales es de entre 10 cm en cada eje, y un pie, es costoso y requiere algoritmos los períodos de observación en el orden de horas para encontrar una ubicación única de descargas parciales. El sistema presentado en este articulo tiene potencial para permitir la detección en tiempo real y la precisión del posicionamiento que superan a los encontrados en la literatura.&lt;/p&gt;&lt;strong&gt;&lt;p&gt;epa más sobre &lt;a href="http://www.amperis.com/productos/detectores-descargas-parciales/"&gt;equipos de medida de descargas parciales&lt;/a&gt; en la web de &lt;a href="http://www.amperis.com/"&gt;instrumentos de medida Amperis&lt;/a&gt;&lt;/p&gt;&lt;/strong&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-4742365830033479976?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/4742365830033479976/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=4742365830033479976' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4742365830033479976'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4742365830033479976'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2009/02/mejorando-la-medida-de-descargas.html' title='Mejorando la medida de descargas parciales'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-1378691075259607225</id><published>2008-10-01T00:01:00.000-07:00</published><updated>2008-10-01T11:39:39.477-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='medida'/><category scheme='http://www.blogger.com/atom/ns#' term='puesta a tierra'/><category scheme='http://www.blogger.com/atom/ns#' term='métodos'/><category scheme='http://www.blogger.com/atom/ns#' term='mediciones'/><category scheme='http://www.blogger.com/atom/ns#' term='ensayos'/><category scheme='http://www.blogger.com/atom/ns#' term='fallos'/><category scheme='http://www.blogger.com/atom/ns#' term='verificación'/><category scheme='http://www.blogger.com/atom/ns#' term='resistencias'/><category scheme='http://www.blogger.com/atom/ns#' term='errores'/><title type='text'>Verificacion de fallos en equipos electricos</title><content type='html'>&lt;h1&gt;Verificacion de fallos en equipos electricos&lt;/h1&gt;&lt;strong&gt;Sinopsis&lt;/strong&gt;&lt;br /&gt;&lt;p&gt;La verificación de fallos es un procedimiento utilizado para confirmar que un &lt;a href="http://www.amperis.com/productos/analizadores-redes/"&gt;equipo de seguridad eléctrica&lt;/a&gt; funciona correctamente y detectará los fallos en dicho dispositivo.&lt;/p&gt;&lt;h3&gt;Mecánica en la naturaleza&lt;/h3&gt;&lt;p&gt;Muchos de los medidores de seguridad disponibles en el mercado eran de la edad analógica.&lt;br /&gt;&lt;br /&gt;Hoy en día los medidores de seguridad son controlados por microprocesador de alta tecnología y software impulsado por circuitos que permiten la verificación con el fin de ser incorporada en el propio instrumento. Estos no sólo eliminan un equipo mecánico extra sino que ahorran costos, además las pruebas son más fáciles y más seguras puesto que no hay nada externo para conectar. El sistema de verificación interna determina si el probador detecta un fallo.&lt;/p&gt;&lt;p&gt;Diversas agencias de seguridad han exigido a los fabricantes realizar estas pruebas, asegurando que los productos funcionen correctamente. Y si bien es posible que un componente cause un mal funcionamiento del instrumento, hay otras condiciones que pueden causar resultados inexactos en ensayos de seguridad eléctrica.&lt;/p&gt;&lt;ul&gt;&lt;br /&gt;&lt;li&gt;&lt;strong&gt;1. &lt;/strong&gt;Si la alta Tensión o la devolución es abierta entonces es posible que el instrumento no detecte errores a causa de esta condición de circuito abierto. Aunque recientes instrumentos modernos usan tecnologías como "Ajustes Bajo Límite" y "Carga DC" la detección ayuda a eliminar este problema. La verificación puede ayudar a asegurar que estos parámetros se establecen correctamente.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;strong&gt;2.&lt;/strong&gt; Muchas pruebas de seguridad se realizan a través de diversos tipos de acople. Esto también crea una condición de circuito abierto que puede ser detectado con bajos límites de carga y ajustes DC-LO. &lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;strong&gt;3.&lt;/strong&gt; Aunque los instrumentos más recientes son más a prueba de manipulaciones, siempre es posible que alguien con el acceso a los menús de configuración puede haber cambiado o desconfigurar los parámetros de detección de sistemas. La verificación puede ayudar a poner a prueba todos los modos de las pruebas de seguridad eléctrica.&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;h3&gt;Requisitos de la Agencia Europea de Seguridad&lt;/h3&gt;&lt;p&gt;La mayor parte de las directrices de la Agencia Europea de Seguridad permiten que el personal que ha sido correctamente formado en el uso de pruebas de seguridad, pueda llevar a cabo la verificación de fallos de los instrumentos. Pero ¿Con qué frecuencia se deben realizar estas pruebas de verificación?. Depende de cada organismo. Algunos organismos pueden exigir que esta prueba se realice varias veces al día. También es muy común realizar puruebas de verificación al comienzo de cada cambio de turno. Sin embargo, otros organismos sólo requieren la verificación al comienzo o al final de cada día.&lt;/p&gt;&lt;p&gt;Por supuesto, el fabricante es el primetro en conocer las directrices de sus respectivos organismos de seguridad.&lt;br /&gt;&lt;br /&gt;Se recomienda que la verificación se realice en cada cambio de turno, ya que es, por lo general un tiempo conveniente para llevar a cabo la prueba y se garantiza el proceso de verificación a un nuevo operador.&lt;/p&gt;&lt;p&gt;Aunque la mayoría de los organismos de seguridad establecen directrices para llevar a cabo la frecuencia de las pruebas verificación, ninguno hace recomendaciones para la forma exacta en que la prueba debe ser realizada. Esto ha dado lugar a cierta confusión y varios métodos diferentes se han recomendado por los fabricantes de instrumentos de ensayo de seguridad eléctrica.&lt;/p&gt;&lt;h3&gt;Métodos de Verificación de ensayo Comunes&lt;/h3&gt;&lt;p&gt;&lt;strong&gt;Métodos de resistencia&lt;/strong&gt; - Resistencias fijas se pueden utilizar para verificar fallos en instrumentos. Muchos fabricantes proporcionan cajas con varios valores comunes de resistencia incorporados. El operador debe seleccionar la resistencia correcta y conectar los conductores de prueba a través de la carga resistiva. La resistencia seleccionada debe ser un valor que permita suficiente flujo de corriente en una prueba de tensión superior a la del instrumento de detección de fallos en circuitos eléctricos.&lt;br /&gt;&lt;br /&gt;La tensión de ensayo puede ser puesta al instante o aumentarla gradualmente al nivel seleccionado. Si la detección del fallo de los circuitos está funcionando correctamente el instrumento debe indicar un error antes de que la prueba de tensión sea alcanzada. Un inconveniente de este método es que no permite variaciones de un producto a otro, por lo que se hace necesario seleccionar y utilizar distintos tipos de valores de resistencia o seleccionar una que genere suficiente corriente para simular el error en todos los dispositivos bajo prueba (DUT's, Device Under Test)&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Método del Switch Externo&lt;/strong&gt; - Otro método muy sencillo para realizar la verificación de la seguridad es simplemente mediante la conexión de los conductores de prueba juntos para crear un corto circuito. Si el instrumento está funcionando correctamente debería notarse un excesivo flujo de corriente e indicar un fallo.&lt;br /&gt;&lt;br /&gt;Si el instrumento indica error durante la detección del fallo significará que el sistema de verificación del Hipot ha sido verificado.&lt;/p&gt;&lt;p&gt; Este mismo procedimiento se puede utilizar para realizar la verificación de fallos IR.&lt;br /&gt;&lt;br /&gt;El cortocircuito será causado por la baja resistencia, que deberá ser tomado como un error del instrumento.&lt;br /&gt;&lt;br /&gt;El comportamiento de la continuidad y la comprobación de la conexión a tierra es similar, salvo que ahora, una conexión de corto se considera adecuada. Recuerde que estas pruebas buscan la continuidad pero una condición abierta ahora representa error. Para simular continuidad y la comprobación de la conexión de &lt;a href="http://www.amperis.com/productos/telurometros/"&gt;puesta a tierra&lt;/a&gt; el conductor de prueba debe quedar abierto, mientras que la prueba se ejecuta para simular un DUT conexión a tierra.&lt;br /&gt;&lt;br /&gt;Aunque este sistema de trabajo dispositivo externo para realizar la prueba de verificación.&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;img style="margin: 0pt 0.5em 0pt 0pt; float: left;" src="http://www.amperis.com/images/megohmetros/megohmetro-mic-5000.jpg" alt="Megóhmetro Medidor aislamiento MIC-5000" width="245" height="280" /&gt;&lt;br /&gt;&lt;p&gt;El medidor de aislamiento modelo MIC-5000 se emplea principalmente en &lt;a href="http://www.amperis.com/productos/megohmetros/" title="Equipos para pruebas de resistencia de aislamiento, Megóhmetros"&gt;pruebas de resistencia de aislamiento&lt;/a&gt; en cables de potencia, motores eléctricos, transformadores, y otros equipos relacionados con la energía eléctrica.&lt;br /&gt;El equipo realiza la medida de tensiones continuas y alternas así como medida de resistencias bajas con tensiones bajas. Los terminales del equipo están protegidos frente a sobretensiones y cumple la norma &lt;a class="glos" title="Descripción del término en el Glosario" href="http://www.amperis.com/recursos/glosario/#IEC61557"&gt;IEC 61557&lt;/a&gt;.&lt;/p&gt;&lt;span style="font-weight: bold;"&gt;Sepa más sobre este fantástico equipo de &lt;/span&gt;&lt;a style="font-weight: bold;" href="http://www.amperis.com/productos/megohmetros/mic-5000/"&gt;medición de aislamiento&lt;/a&gt;&lt;span style="font-weight: bold;"&gt; en la web de Amperis - &lt;/span&gt;&lt;a style="font-weight: bold;" href="http://www.amperis.com/"&gt;Instrumentos de medicion&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-1378691075259607225?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/1378691075259607225/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=1378691075259607225' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1378691075259607225'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1378691075259607225'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/10/verificacion-de-fallos-en-equipos.html' title='Verificacion de fallos en equipos electricos'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-377396040677135885</id><published>2008-09-23T01:48:00.000-07:00</published><updated>2008-09-23T01:53:51.910-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='tensión'/><category scheme='http://www.blogger.com/atom/ns#' term='frecuencia'/><category scheme='http://www.blogger.com/atom/ns#' term='tiempo RL'/><category scheme='http://www.blogger.com/atom/ns#' term='resistencia'/><category scheme='http://www.blogger.com/atom/ns#' term='intervalos'/><category scheme='http://www.blogger.com/atom/ns#' term='resistores'/><category scheme='http://www.blogger.com/atom/ns#' term='impedancia'/><title type='text'>Calculadoras: frecuencia, resistencia, ohm, tension</title><content type='html'>Pequeña colección de Calculadoras: frecuencia, resistencia, ley de ohm, impedancia, tension, frecuencia e intervalo para el aficionado o estudiante.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://www.dannyg.com/examples/res2/resistor.htm" target="_blank"&gt;Calculadora de valores de resistencia mediante los colores&lt;/a&gt; - &lt;em&gt;(en Inglés)&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ourworld.compuserve.com/homepages/Bill_Bowden/resistor.htm" target="_blank"&gt;Otra calculadora de resistores&lt;/a&gt; - Este utiliza casillas de verificación en lugar de la lista desplegable de menús y también calcula el valor equivalente de dos resistencias en paralelo. &lt;em&gt;(en Inglés)&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ourworld.compuserve.com/homepages/Bill_Bowden/ohmslaw.htm" target="_blank"&gt;Calculadora de Ley de Ohm&lt;/a&gt; - JavaScript para resolver la Ley de Ohm para tensión, corriente, Resistencia y Potencia. Introduzca los dos incógnitas por resolver. &lt;em&gt;(en Inglés)&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ourworld.compuserve.com/homepages/Bill_Bowden/r2.htm" target="_blank"&gt;Calculadora de tensión&lt;/a&gt; - Calcula tensión, corriente, y problemas de disipación de energía por dos elementos divisores resistivos de tensión. &lt;em&gt;(en Inglés)&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://pr.erau.edu/%7Enewmana/imped.html" target="_blank"&gt;Calculadora de Impedancia&lt;/a&gt; - Calcula la reactancia, impedancia y el ángulo de fase.&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ourworld.compuserve.com/homepages/Bill_Bowden/rc.htm" target="_blank"&gt;Calculadora RC&lt;/a&gt;- JavaScript para resolver R y C. &lt;em&gt;(en Inglés)&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ourworld.compuserve.com/homepages/Bill_Bowden/rl.htm" target="_blank"&gt;Calculadora de Tiempo RL&lt;/a&gt; - Java Script para resolver los R y L para determinados valores de los valores instantáneos. &lt;em&gt;(en Inglés)&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ourworld.compuserve.com/homepages/Bill_Bowden/555.htm" target="_blank"&gt;Calculadora de Frecuencia e Intervalo de tiempo&lt;/a&gt; - Calcula los intervalos de tiempo para el temporizador 555 sobre la base de R y C. También contiene descripciones y el funcionamiento de cada entrada y salida del temporizador y los esquemas de los dos modos básicos de operación. &lt;em&gt;(en Inglés).&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/em&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-377396040677135885?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/377396040677135885/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=377396040677135885' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/377396040677135885'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/377396040677135885'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/09/calculadoras-frecuencia-resistencia-ohm.html' title='Calculadoras: frecuencia, resistencia, ohm, tension'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-4836592995638831843</id><published>2008-09-22T23:38:00.000-07:00</published><updated>2008-09-22T23:41:40.381-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='medida electrica'/><category scheme='http://www.blogger.com/atom/ns#' term='telurometros'/><category scheme='http://www.blogger.com/atom/ns#' term='aislamiento eléctrico'/><title type='text'>La Medida Electrica</title><content type='html'>&lt;p&gt;Medición o medida (acción y resultado de medir), es la comparación de la cantidad de una magnitud física con la cantidad contenida en otra magnitud de igual naturaleza que se toma como unidad&lt;/p&gt;&lt;h2&gt;1.  Concepto de medida&lt;/h2&gt;&lt;p&gt;Por tanto, el resultado de una medición (o medida) es una cantidad expresada por un número que indica cuántas unidades contiene la magnitud objeto de tal análisis.&lt;br /&gt;&lt;br /&gt; Atendiendo a la finalidad, cabe hacer la distinción entre dos tipos de mediciones que son comunes para cualquiera que sea la naturaleza del objeto a medir: eléctrica, mecánicas, hidráulica, térmica, lumínica, sonora, etc. Estos dos tipos son:&lt;/p&gt;&lt;p&gt;— &lt;strong&gt;Mediciones Técnicas&lt;/strong&gt; destinadas a determinar valores de cantidades de magnitudes físicas con fines de información, control, protección o facturación, realizadas generalmente «in situ» o en Laboratorios ubicados dentro de unidades productivas, que utilizan instrumentación no excesivamente sofisticada o cara y relativamente versátil. Ejemplo de este tipo de mediciones se pueden encontrar constantemente en la vida cotidiana: básculas de los mercados de abastecimientos, contadores de agua, gas o energía eléctrica, cintas métricas, fotómetros y sonómetros, termómetros, cuentarrevoluciones, etc.&lt;/p&gt;&lt;p&gt;— &lt;strong&gt;Mediciones Metrológicas y Calibraciones&lt;/strong&gt;. Son aquéllos procesos realizados con regularidad, en los que se incluyen mediciones que están destinados a certificar legalmente la calidad y clase de precisión tanto de los instrumentos de mediciones técnicas como de otros elementos de calibración de orden inferior. En las calibraciones, más que mediciones se realizan comparaciones de las indicaciones del instrumento en prueba con los parámetros proporcionados por elementos físicos denominados Patrones (o Calibradores); patrones que, a su vez, deben calibrarse por comparación con otros de nivel superior, prolongándose la cadena hasta los patrones Primarios o absolutos. La existencia identificada y documentada de una cadena completa que abarque desde el instrumento de medición o calibración hasta el patrón o los patrones primarios, al menos Nacionales, se denomina &lt;strong&gt;TRAZABILIDAD.&lt;br /&gt;&lt;br /&gt; &lt;/strong&gt;Por supuesto este tipo de operaciones sólo pueden llevarse a cabo en Laboratorios Reconocidos y equipados con materiales y patrones de elevado coste y de los que en España sólo existen una docena escasa. Es conveniente hacer notar que sea cual sea el tipo de medida, los procesos de comparación de la magnitud a medir con su unidad o con su valor equivalente, así como la obtención del resultado numérico, siempre tienen imperfecciones, lo que da lugar a que el resultado contenga un mayor o menor grado de &lt;em&gt;incertidumbre o imprecisión &lt;/em&gt;o, lo que es lo mismo, que el valor numérico obtenido sea &lt;strong&gt;distinto del valor real exacto, el cual será siempre desconocido, aunque afortunadamente acotable &lt;/strong&gt;&lt;sup&gt;(1)&lt;/sup&gt;.&lt;/p&gt;&lt;p&gt;Un ejemplo puede ayudarnos a comprender estas últimas afirmaciones que a priori parecen desconsoladoras.&lt;/p&gt;&lt;h2&gt;2.  Ejemplo de medición&lt;/h2&gt;&lt;p&gt;Veamos con detalle un ejemplo de tipo mecánico que puede ser com­prendido sin necesidad de conocimientos específicos eléctricos previos.&lt;/p&gt;&lt;br /&gt;&lt;p class="c"&gt;&lt;img src="http://www.amperis.com/images/articulos/medicion-masa-objeto-material.gif" alt="Medición de la masa de un objeto material" width="337" height="143" /&gt;&lt;br /&gt;&lt;span&gt;Medición de la masa de un objeto material&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;small&gt;(1) Naturalmente los procesos de determinación del número de objetos contenidos en un conjunto pueden proporcionar valores absolutamente exactos cuando dichos procesos se realizan por cómputo, pero a un proceso de tal naturaleza no se le denomina medir, sino contar.&lt;/small&gt;&lt;br /&gt;&lt;br /&gt;Sepa más sobre &lt;a href="http://www.amperis.com/"&gt;equipos de medida eléctrica&lt;/a&gt;, como &lt;a href="http://www.amperis.com/productos/ohmimetros/" title="Enlace externo a la sección Ohmetros de Amperis"&gt;ohmetro&lt;/a&gt;, &lt;a href="http://www.amperis.com/productos/telurometros/" title="Enlace externo a la sección Telurometros de Amperis"&gt;telurometro&lt;/a&gt;, &lt;a href="http://www.amperis.com/productos/megohmetros/" title="Enlace externo a la sección Megohmetros de Amperis"&gt;equipos de medida de aislamiento eléctrico&lt;/a&gt; y otros equipos en la web de Amperis, &lt;a href="http://www.amperis.com/"&gt;www.amperis.com &lt;/a&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-4836592995638831843?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/4836592995638831843/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=4836592995638831843' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4836592995638831843'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4836592995638831843'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/09/la-medida-electrica.html' title='La Medida Electrica'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6870217055916612316</id><published>2008-09-18T15:47:00.000-07:00</published><updated>2008-09-18T15:51:31.847-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='tarifas'/><category scheme='http://www.blogger.com/atom/ns#' term='electricas'/><title type='text'>Tarifas electricas</title><content type='html'>Todo lo que hay que saber sobre las tarifas eléctricas.&lt;br /&gt;Autores: Bernabé Blanco de IES "El Arenal" de Dos Hermanas (Sevilla)&lt;br /&gt;&lt;br /&gt;&lt;a href="http://www.juntadeandalucia.es/averroes/%7E41001719/electricos/3fp2/tarifas1.html" target="_blank"&gt;Ver en nueva ventana&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;iframe src="http://www.juntadeandalucia.es/averroes/%7E41001719/electricos/3fp2/tarifas1.swf" marginheight="0" marginwidth="0" scrolling="no" width="562" frameborder="0" height="537"&gt;&lt;/iframe&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6870217055916612316?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6870217055916612316/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6870217055916612316' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6870217055916612316'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6870217055916612316'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/09/tarifas-electricas.html' title='Tarifas electricas'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-8659761908264773351</id><published>2008-09-18T14:13:00.000-07:00</published><updated>2008-09-18T14:21:14.829-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='capacitancia'/><title type='text'>Capacitancia</title><content type='html'>&lt;h3&gt;Capacitancia, definición&lt;/h3&gt;&lt;br /&gt;Consideremos dos conductores que tienen una diferencia de potencial V entre ellos, y supongamos que los dos conductores tienen cargas iguales y de signo opuesto.  Esto se puede lograr conectando los dos conductores descargados a las terminales de una batería.  Una combinación de conductores así cargados es un dispositivo conocido como condensador.  Se encuentra que la diferencia de potencial V es proporcional a la carga Q en el condensador.&lt;br /&gt;&lt;br /&gt;&lt;b&gt;Capacitancia.&lt;/b&gt;&lt;br /&gt;La capacitancia entre dos conductores que tienen cargas de igual magnitud y de signo contrario es la razón de la magnitud de la carga en uno u otro conductor con la diferencia de potencial resultante entre ambos conductores.&lt;br /&gt;&lt;br /&gt;C = &lt;u&gt;Q&lt;/u&gt;&lt;br /&gt;                   V&lt;br /&gt;&lt;br /&gt;Obsérvese que por definición la capacitancia es siempre una cantidad positiva.  Además, como la diferencia de potencial aumenta al aumentar la carga almacenada en el condensador, la razón Q/V es una constante para un condensador dado.  Por lo tanto, la capacitancia de un dispositivo es la medida de su capacidad de almacenar carga y energía potencial eléctrica.&lt;br /&gt;&lt;br /&gt;Las unidades de la capacitancia en el SI son el &lt;span style="font-style: italic;"&gt;Coulomb&lt;/span&gt; por Volt.  La unidad en el SI para la capacitancia es el &lt;span style="font-weight: bold;"&gt;faradio&lt;/span&gt; (F), en honor a Michael Faraday.&lt;br /&gt;&lt;br /&gt;1 farad (F) = &lt;u&gt;1 coulomb (C)&lt;/u&gt;&lt;br /&gt;                                                                        1 volt (V)&lt;br /&gt;&lt;br /&gt;&lt;a href="http://www.amperis.com"&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-8659761908264773351?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/8659761908264773351/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=8659761908264773351' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8659761908264773351'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8659761908264773351'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/09/capacitancia.html' title='Capacitancia'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-1144273325841359962</id><published>2008-08-14T09:36:00.000-07:00</published><updated>2008-08-14T09:38:39.511-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='medidores'/><category scheme='http://www.blogger.com/atom/ns#' term='medida'/><category scheme='http://www.blogger.com/atom/ns#' term='mediciones'/><category scheme='http://www.blogger.com/atom/ns#' term='resistencia'/><category scheme='http://www.blogger.com/atom/ns#' term='aislamiento'/><title type='text'>Medición del Aislamiento</title><content type='html'>&lt;p&gt;Los daños debidos a sobretensiones en equipos electrónicos (ordenadores, tv., vídeo, etc.) e instalaciones vienen aumentando desde hace años. Esto se debe al empleo de componentes electrónicos cada día más sensibles a dichas sobretensiones.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;En especial, los sistemas informáticos pueden sufrir importantes daños o incluso llegar a destruirse si no están convenientemente protegidos. Al coste de estos desperfectos producidos en los propios aparatos o en la instalación, es necesario sumar los costes añadidos por ausencia de servicio durante días.&lt;/p&gt;&lt;br /&gt;&lt;h2&gt;CAUSAS DE LAS SOBRETENSIONES TRANSITORIAS&lt;/h2&gt;&lt;br /&gt;&lt;p&gt; Las causas que ocasionan una sobretensión transitoria son variadas, pero todas ellas pueden englobarse en los 4 grupos que se describen a continuación:&lt;/p&gt;-Impacto directo del rayo, caso en el que éste alcanza directamente el edificio, haciendo que los conductores de la instalación se vean sometidos en breves periodos de tiempo a potenciales muy elevados que ocasionan la destrucción instantánea de los equipos electrónicos conectados a dicha instalación.&lt;br /&gt;&lt;p&gt; -Impacto lejano, casos en los que el edificio no ha sido alcanzado directamente por el rayo, pese a lo cual el funcionamiento de la instalación se ve afectado debido a la onda de expansión que se transmite a través de las líneas de alimentación de la red eléctrica.&lt;/p&gt;&lt;br /&gt;&lt;p&gt; -Impactos entre nubes, casos en los que el rayo rebota de nube a nube. La instalación eléctrica puede verse afectada debido a las cargas de reflexión que intervienen en dicho fenómeno atmosférico y provocan aumentos en el potencial de los conductores, especialmente si estos provienen del exterior del edificio.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;-Procesos de conmutación, tales como operaciones de encendido y apagado, contactos a tierra accidentales, conmutaciones de cargas inductivas o capacitivas, etc. que hacen que, al igual que en los tres casos anteriores, se produzcan riesgos de sobretensiones que provocan fallos en el funcionamiento normal de los equipos.&lt;/p&gt;&lt;h2&gt;PRUEBAS ESTABLECIDAS&lt;/h2&gt;&lt;p&gt;Las instalaciones de alta tensión construidas según las normas de la serie DIN VDE 0100 han de someterse a las pruebas establecidas en dicha norma, parte 610, cuando son instaladas, modificadas o ampliadas. Estas pruebas no sólo abarcan las diferentes mediciones para comprobar el funcionamiento de las medidas de protección y la conexión equipotencial, sino que también son válidas para comprobar la resistencia de aislamiento.&lt;/p&gt;&lt;p&gt;Dichas pruebas deben realizarse al poner en servicio la instalación y repetirse, después, en modificaciones, trabajos de reparación o ampliaciones de una instalación eléctrica. El instalador ha de demostrar que la instalación cumple las exigencias en cuanto a protección de seres humanos, animales y equipos electrónicos [1]. Vamos a ver ahora qué peso tiene la medición de la resistencia de aislamiento dentro de las pruebas obligatorias y hasta qué punto las instalaciones consumidoras conectadas o las protecciones contra sobretensiones pueden falsear los resultados de la prueba.&lt;/p&gt;&lt;p&gt;En términos generales, con la medición del aislamiento, el propietario o usuario de la instalación obtiene datos sobre el estado de seguridad de la instalación. Si la resistencia es muy baja los cables se ven sometidos a cargas excesivas que pueden convertirse en el foco de un incendio. Fue justo este hecho el que provocó que las compañías de seguros impusieran mediciones periódicas del aislamiento para instalaciones eléctricas industriales.&lt;br /&gt;&lt;br /&gt; &lt;strong&gt;¿Pero qué significa una &lt;a href="http://www.amperis.com/productos/megohmetros/"&gt;baja resistencia de aislamiento&lt;/a&gt; y cómo podemos detectarla?&lt;/strong&gt;.&lt;br /&gt;&lt;br /&gt;También aquí la norma (DIN VDE 0100, parte 610) es muy explícita. En la &lt;a href="http://www.blogger.com/post-create.g?blogID=5684890127023020349#tabla"&gt;tabla 1&lt;/a&gt; se indican las tensiones de medición a aplicar y las resistencias de aislamiento permitidas.&lt;/p&gt;&lt;p&gt;Como se ve en dicha &lt;a href="http://www.blogger.com/post-create.g?blogID=5684890127023020349#tabla"&gt;tabla&lt;/a&gt;, en las instalaciones con una tensión nominal de 230/400 V la medición de aislamiento se realiza con una tensión continua de 500V. La resistencia entre los puntos que a continuación se describen tiene que ser superior a 0,5 MW, teniendo en cuenta que al medir con corriente continua se excluyen las interferencias derivadas de las capacidades de los cables.&lt;/p&gt;&lt;p&gt;El aparato de medición deberá cumplir también, como es lógico, las exigencias de la norma DIN VDE 0413, parte 1.&lt;br /&gt;&lt;br /&gt;Ahora es importante saber entre qué conductores ha de realizarse la medición. De nuevo encontramos la respuesta en la norma, que establece los siguientes puntos:&lt;/p&gt;&lt;ul&gt;&lt;li&gt;a) entre las fases activas (L1, L2, L3) y el conductor de protección (PE).&lt;/li&gt;&lt;br /&gt; &lt;li&gt;b) entre el neutro (N) y el conductor de protección (PE).&lt;/li&gt;&lt;br /&gt; &lt;li&gt;c) entre las fases activas (L1, L2, L3).&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;La resistencia de aislamiento ha de realizarse sin conexión a la red, pero las instalaciones consumidoras pueden seguir conectadas si se alcanzan los valores expuestos en la tabla anterior. En caso contrario hay que desconectar las instalaciones consumidoras de la red para llevar a cabo la prueba. No obstante conviene comprobar si al circuito a probar están conectados dispositivos eléctricos con componentes electrónicos o sensibles que puedan verse afectados por la tensión de prueba&lt;/p&gt;&lt;table id="tabla" summary="Tabla de tensiones de medición a aplicar y las resistencias de aislamiento permitidas." width="100%"&gt;&lt;br /&gt;   &lt;caption&gt;&lt;br /&gt;   &lt;em&gt;Tabla de tensiones de medición a aplicar y las resistencias de aislamiento permitidas.&lt;/em&gt;&lt;/caption&gt;  &lt;tbody&gt;&lt;br /&gt;   &lt;tr&gt;&lt;br /&gt;     &lt;th style="border: 1px solid rgb(0, 0, 0);"&gt;&lt;strong&gt;Tensión nominal del circuito&lt;/strong&gt;&lt;/th&gt;&lt;br /&gt;     &lt;th style="border: 1px solid rgb(0, 0, 0);"&gt;&lt;strong&gt;Tensión de prueba V&lt;/strong&gt;&lt;/th&gt;&lt;br /&gt;     &lt;th style="border: 1px solid rgb(0, 0, 0);"&gt;&lt;strong&gt;Valor mínimo de la resistencia de aislamiento MW&lt;/strong&gt;&lt;/th&gt;&lt;br /&gt;   &lt;/tr&gt;&lt;br /&gt;   &lt;tr&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;Circuitos de protección o control de reducida tensión&lt;/td&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;250&lt;/td&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt; 0,25 &lt;/td&gt;&lt;br /&gt;   &lt;/tr&gt;&lt;br /&gt;   &lt;tr&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;Tensión nominal menor de 500 V, si no se trata de circuitos de protección o control de reducida tensión&lt;/td&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;500&lt;/td&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;0,5&lt;/td&gt;&lt;br /&gt;   &lt;/tr&gt;&lt;br /&gt;   &lt;tr&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;Tensión nominal mayor de 500 V&lt;/td&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;1000&lt;/td&gt;&lt;br /&gt;     &lt;td style="border: 1px solid rgb(0, 0, 0);"&gt;1,0&lt;/td&gt;&lt;br /&gt;   &lt;/tr&gt;&lt;br /&gt; &lt;/tbody&gt;&lt;br /&gt;&lt;/table&gt;&lt;br /&gt;&lt;p&gt;Dispone de más información acerca de &lt;a href="http://www.amperis.com/productos/megohmetros/" title="Medidores de Aislamiento" accesskey="m"&gt;Medidores de Aislamiento&lt;/a&gt; en &lt;a href="http://www.amperis.com/productos/megohmetros/" title="Amperis - Equipos de medida eléctrica" accesskey="a"&gt;Amperis&lt;/a&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-1144273325841359962?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/1144273325841359962/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=1144273325841359962' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1144273325841359962'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1144273325841359962'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/08/medicin-del-aislamiento.html' title='Medición del Aislamiento'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-3651529757935259975</id><published>2008-06-13T05:37:00.000-07:00</published><updated>2008-06-13T05:41:10.218-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='ohmetro'/><category scheme='http://www.blogger.com/atom/ns#' term='laboratorio'/><category scheme='http://www.blogger.com/atom/ns#' term='medidas'/><title type='text'>Notas Introductorias para trabajar en laboratorio</title><content type='html'>&lt;object height="355" width="425"&gt;&lt;param name="movie" value="http://www.youtube.com/v/ytk1T4FlwVI&amp;amp;rel=1"&gt;&lt;embed src="http://www.youtube.com/v/ytk1T4FlwVI&amp;amp;rel=1" type="application/x-shockwave-flash" height="355" width="425"&gt;&lt;/embed&gt;&lt;/object&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Uso del Multímetro&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;El &lt;u&gt;multímetro&lt;/u&gt; es un instrumento que se utiliza para medir diversos parámetros en los circuitos eléctricos. Comprende varios instrumentos en uno, ya que usualmente incluye &lt;u&gt;voltímetro&lt;/u&gt; (para medir diferencias de potencial), &lt;u&gt;amperímetro&lt;/u&gt; (para medir corrientes) y &lt;a href="http://www.amperis.com/productos/ohmimetros/"&gt;&lt;u&gt;ohmetro&lt;/u&gt;&lt;/a&gt; (para medir resistencias), cada uno con varias escalas de medición.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Medición de diferencia de potencial&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Para medir diferencia de potencial (tensión o voltaje) sobre un elemento de un circuito eléctrico, se deben colocar las puntas de medición del &lt;u&gt;voltímetro&lt;/u&gt; sobre cada uno de los extremos del mencionado elemento, realizando una conexión en &lt;u&gt;paralelo&lt;/u&gt;.&lt;br /&gt;&lt;br /&gt;Para que la medición de tensión no interfiera con el circuito, es evidente que por el voltímetro debe circular la menor corriente posible, de modo que la corriente circulante sobre el elemento en el cual estamos midiendo diferencia de potencial no se vea afectada. De esto se deduce que la resistencia interna del voltímetro debe ser mucho mayor que la resistencia del elemento sobre el cual se quiere medir la tensión. Un voltímetro ideal debería tener &lt;u&gt;resistencia interna infinita&lt;/u&gt;.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Medición de resistencia&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;La conexión es idéntica al caso anterior, (una punta en cada extremo del conductor cuya resistencia se quiere medir) debiendo elegirse la posición correspondiente de la llave selectora. La aparición de un “1” a la izquierda del &lt;em&gt;display&lt;/em&gt; estará indicando que la resistencia es mayor que el rango seleccionado, por lo que deberá aumentarse éste hasta conseguir una lectura positiva.&lt;br /&gt;&lt;br /&gt;&lt;u&gt;Atención&lt;/u&gt;: La medición de resistencias debe hacerse &lt;u&gt;sin tensión presente.&lt;/u&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Medición de corriente eléctrica&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Si se desea medir la corriente que circula por una rama de un circuito eléctrico, se debe &lt;u&gt;intercalar&lt;/u&gt; un &lt;u&gt;amperímetro&lt;/u&gt; en esa rama, de forma tal que la corriente pase en su totalidad por dicho instrumento, realizando una conexión en &lt;u&gt;serie&lt;/u&gt;.&lt;br /&gt;&lt;br /&gt;Para que la medición de corriente no interfiera con el circuito original, es evidente que la intercalación del amperímetro no debe modificar la corriente que circulaba por esa rama del circuito. Para esto la resistencia interna del amperímetro debe ser mucho menor que la resistencia equivalente de la rama donde fue intercalado. Un amperímetro ideal debería tener &lt;u&gt;resistencia interna nula&lt;/u&gt;.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Recomendaciones sobre cómo medir&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Si bien el multímetro es un instrumento que ofrece una amplia gama de posibilidades para medir, es justamente esta flexibilidad la que puede transformarlo en víctima de nuestros descuidos.&lt;br /&gt;&lt;br /&gt;Es &lt;u&gt;muy importante&lt;/u&gt; verificar antes de realizar cada medición que el multímetro se encuentre seleccionado en el &lt;u&gt;tipo&lt;/u&gt; y &lt;u&gt;rango&lt;/u&gt; de la magnitud a medir. Ejercicio: responda qué pasaría si se intentara medir una tensión con el multímetro trabajando como amperímetro.&lt;br /&gt;&lt;br /&gt;Una vez que sepa lo que quiere medir, seleccione el tipo de magnitud en el multímetro y comience utilizando el rango más alto del instrumento. Siempre razone antes de medir.&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-3651529757935259975?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/3651529757935259975/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=3651529757935259975' title='1 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/3651529757935259975'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/3651529757935259975'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/06/notas-introductorias-para-trabajar-en.html' title='Notas Introductorias para trabajar en laboratorio'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-8499990372142169732</id><published>2008-05-29T05:29:00.000-07:00</published><updated>2008-05-29T05:31:49.500-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='óhmetros'/><category scheme='http://www.blogger.com/atom/ns#' term='ohmetro'/><category scheme='http://www.blogger.com/atom/ns#' term='resistencia'/><category scheme='http://www.blogger.com/atom/ns#' term='multímetro'/><title type='text'>ÓHMETRO O MULTÍMETRO</title><content type='html'>&lt;strong&gt;&lt;br /&gt;&lt;p&gt;&lt;a href="http://www.amperis.com/productos/ohmimetros/"&gt;ÓHMETRO O MULTÍMETRO&lt;/a&gt;&lt;/p&gt;&lt;/strong&gt;&lt;br /&gt;&lt;p&gt;Un &lt;strong&gt;&lt;a href="http://www.amperis.com/productos/ohmimetros/"&gt;óhmetro&lt;/a&gt;&lt;/strong&gt; es un instrumento para medir la resistencia eléctrica.&lt;/p&gt;&lt;p&gt; El diseño de un &lt;a href="http://www.amperis.com/productos/ohmimetros/"&gt;ohmetro&lt;/a&gt; se compone de una pequeña batería para aplicar un voltaje a la resistencia bajo medida, para luego mediante un galvanómetro medir la corriente que circula a través de la resistencia.&lt;/p&gt;&lt;p&gt; La escala del galvanómetro está calibrada directamente en ohmios, ya que en aplicación de la &lt;a href="http://www.google.es/url?sa=t&amp;amp;ct=res&amp;amp;cd=1&amp;amp;url=http%3A%2F%2Fes.wikipedia.org%2Fwiki%2FLey_de_Ohm&amp;amp;ei=5qA-SNXBBoWYQpnq7KQN&amp;amp;usg=AFQjCNEv_1Cl_6G57LWbqA7KjG7_C86v4Q&amp;amp;sig2=YwlquN4YEMx_J-HhDHDaOw"&gt;ley de Ohm&lt;/a&gt;, al ser el voltaje de la batería fijo, la intensidad circulante a través del galvanómetro sólo va a depender del valor de la resistencia bajo medida, esto es, a menor resistencia mayor intensidad de corriente y viceversa.&lt;/p&gt;&lt;p&gt;Existen también otros tipos de óhmetros más exactos y sofisticados,  en los que la batería ha sido sustituida por un circuito que genera una  corriente de intensidad constante &lt;strong&gt;I&lt;/strong&gt;, la cual se hace circular a través de la resistencia &lt;strong&gt;R&lt;/strong&gt; bajo prueba. Luego, mediante otro circuito se mide el voltaje &lt;strong&gt;V&lt;/strong&gt; en los extremos de la resistencia. De acuerdo con la ley de Ohm el valor de &lt;strong&gt;R&lt;/strong&gt; vendrá dado por:&lt;/p&gt;&lt;p align="center"&gt;&lt;img src="http://www.amperis.com/images/ohmetros/ecuacion-resistencia.gif" alt="Ohmetro ecuación de la resistencia" height="42" width="48" /&gt;&lt;/p&gt;&lt;p&gt;Para medidas de alta precisión la disposición indicada anteriormente no es apropiada, por cuanto que la lectura del medidor es la suma de la resistencia de los cables de medida y la  de la resistencia bajo prueba. Para evitar este inconveniente, un  óhmetro de precisión tiene cuatro terminales, denominados contactos Kelvin [&lt;a href="http://www.amperis.com/productos/ohmimetros/#metodo-kelvin"&gt;medida de resistencia por el método Kelvin&lt;/a&gt;]. Dos terminales llevan la corriente constante desde el medidor a  la resistencia, mientras que los otros dos permiten la medida del  voltaje directamente entre terminales de la misma, con lo que la caída  de tensión en los conductores que aplican dicha corriente constante a  la resistencia bajo prueba no afecta a la exactitud de la medida.&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-8499990372142169732?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/8499990372142169732/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=8499990372142169732' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8499990372142169732'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8499990372142169732'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/05/hmetro-o-multmetro.html' title='ÓHMETRO O MULTÍMETRO'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-9056027506038574353</id><published>2008-05-21T04:57:00.000-07:00</published><updated>2008-05-21T05:01:10.487-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='medida'/><category scheme='http://www.blogger.com/atom/ns#' term='ensayos'/><category scheme='http://www.blogger.com/atom/ns#' term='ohmetros'/><category scheme='http://www.blogger.com/atom/ns#' term='comprobaciones'/><title type='text'>Comprobaciones con Ohmetro</title><content type='html'>&lt;h3&gt;Diversas comprobaciones en una Moto usando un &lt;a href="http://www.amperis.com/productos/ohmimetros/"&gt;Óhmetro&lt;/a&gt;&lt;/h3&gt;&lt;span style="font-style: italic;"&gt;1 - Comprobación bobina encendido en una moto&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;Pila de 6V fabricada con 4 de 1'5V y la bombilla de 6V del velocímetro. Un polo al cable verde y el otro a masa.&lt;br /&gt;&lt;a href="http://4.bp.blogspot.com/_wlgxiFGoKFo/RyHvhvUeUwI/AAAAAAAAA0M/S8J0ip_LwxI/s1600-h/PICT00226.5+Fabricaci%C3%B3n+pila+6V+para+prueba.jpg"&gt;&lt;img style="margin: 0pt 10px 10px 0pt; float: left; cursor: pointer;" src="http://4.bp.blogspot.com/_wlgxiFGoKFo/RyHvhvUeUwI/AAAAAAAAA0M/S8J0ip_LwxI/s200/PICT00226.5+Fabricaci%C3%B3n+pila+6V+para+prueba.jpg" alt="" id="BLOGGER_PHOTO_ID_5125641213841396482" border="0" /&gt;&lt;/a&gt; &lt;object height="150" width="225"&gt; &lt;param name="movie" value="http://www.youtube.com/v/pA9xFOwfH3c"&gt;  &lt;embed src="http://www.youtube.com/v/pA9xFOwfH3c" type="application/x-shockwave-flash" height="150" width="225"&gt;&lt;/embed&gt;  &lt;/object&gt;&lt;br /&gt;&lt;br /&gt;&lt;em&gt;2 - Comprobación condensador&lt;/em&gt; &lt;a href="http://4.bp.blogspot.com/_wlgxiFGoKFo/R1u9Y0-7tYI/AAAAAAAAA8k/9xWYo3BjG68/s1600-h/PICT00226.4.9.4+Condensador.jpg"&gt;&lt;img style="margin: 0pt 0pt 8px 8px; float: right; cursor: pointer;" src="http://4.bp.blogspot.com/_wlgxiFGoKFo/R1u9Y0-7tYI/AAAAAAAAA8k/9xWYo3BjG68/s200/PICT00226.4.9.4+Condensador.jpg" alt="" id="BLOGGER_PHOTO_ID_5141911633810666882" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;CORTOCIRCUITO (Ω)&lt;br /&gt;1º.-Descargar antes y después de la prueba. (Poner un cable de la punta al exterior).&lt;br /&gt;2º.-Poner el &lt;a href="http://www.amperis.com/productos/ohmimetros/"&gt;Ohmetro&lt;/a&gt; a cero con las sondas colocadas, una al exterior y otra en la punta. La lectura de la resistencia debe ser que este fuera de rango.&lt;br /&gt;&lt;br /&gt;FUGA DE CORRIENTE (V)&lt;br /&gt;Poner el multímetro en medición de CC y mantenerlo unos segundos. Invertir los polos y medida debería acercarse al valor 0'000.&lt;br /&gt;CAPACIDAD (μF)&lt;br /&gt;El normal para la mayoría de las motos es 0’25 Me sale 0’46. Pero es válida y mide si carga y descarga bien.&lt;br /&gt;&lt;br /&gt;&lt;em&gt;Bujía+pipa+cable&lt;/em&gt;&lt;br /&gt;Para uso urbano: NGK B7ES. B=Tipo rosca 14mm, 7=Calificación de calor (2 Caliente - 11 Frio) y ES= Longitud rosca 19mm (3/4")y Diam electrodo central estándar 2,5mm. Distancia para la chispa: 0'5 - 0'6 mm.&lt;br /&gt;&lt;br /&gt;&lt;em&gt;&lt;/em&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-9056027506038574353?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/9056027506038574353/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=9056027506038574353' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/9056027506038574353'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/9056027506038574353'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/05/comprobaciones-con-ohmetro.html' title='Comprobaciones con Ohmetro'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_wlgxiFGoKFo/RyHvhvUeUwI/AAAAAAAAA0M/S8J0ip_LwxI/s72-c/PICT00226.5+Fabricaci%C3%B3n+pila+6V+para+prueba.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-366356331374688125</id><published>2008-05-14T03:36:00.000-07:00</published><updated>2008-05-14T03:52:11.456-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='ahorro'/><category scheme='http://www.blogger.com/atom/ns#' term='rendimiento'/><category scheme='http://www.blogger.com/atom/ns#' term='redes eléctricas'/><category scheme='http://www.blogger.com/atom/ns#' term='iberdrola'/><title type='text'>Camaras termograficas para mantener en buen estado las instalaciones</title><content type='html'>&lt;span style="font-weight: bold;"&gt;Detectar puntos con temperaturas inadecuadamente altas (&lt;span style="font-style: italic;"&gt;puntos calientes&lt;/span&gt;) y evaluar el rendimiento de las redes eléctricas es uno de los objetivos de las cámaras termográficas.&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;p&gt;Iberdrola revisó 3.200 kilómetros de líneas eléctricas durante el año pasado en la región con el objetivo de reforzar la seguridad del suministro para el invierno. Así, la compañía ha inspeccionado 550 kilómetros de líneas aéreas de muy alta tensión, 600 de alta tensión y 2.000 kilómetros de media tensión. &lt;/p&gt;&lt;p&gt; Iberdrola explicó que ha realizado la revisión ordinaria de más de 400 kilómetros de líneas aéreas de muy alta tensión --de 132 kilovoltios--, un reconocimiento que está obligada a cumplir de cara a detectar las anomalías más habituales en una instalación de estas características: &lt;span style="font-weight: bold;"&gt;Rotura de aisladores, daños por rayos, caída de arbolado, obras de construcción o edificaciones próximas&lt;/span&gt;... &lt;/p&gt;&lt;p&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_liWG2cxeH1g/SCrENMA_mHI/AAAAAAAAAPw/1czBZCmKeJY/s1600-h/345573_2.jpg"&gt;&lt;img style="margin: 0pt 10px 10px 0pt; float: left; cursor: pointer;" src="http://4.bp.blogspot.com/_liWG2cxeH1g/SCrENMA_mHI/AAAAAAAAAPw/1czBZCmKeJY/s320/345573_2.jpg" alt="" id="BLOGGER_PHOTO_ID_5200184450595395698" border="0" /&gt;&lt;/a&gt; Por otro lado, la compañía destacó que ha desarrollado una serie de actuaciones por iniciativa propia analizando cerca de 2.800 kilómetros de sus líneas aéreas. Esta revisión se ha desarrollado en 150 kilómetros de líneas aéreas de muy alta tensión, 600 de alta tensión y 2.000 de media tensión. &lt;/p&gt;&lt;p&gt; Asimismo, la empresa ha revisado por infrarrojos más de 50 kilómetros de líneas. Esta acción, llevada a cabo en los meses previos al invierno, consiste en el reconocimiento de estas infraestructuras mediante &lt;a href="http://www.amperis.com/productos/camaras-termograficas/"&gt;cámaras termográficas&lt;/a&gt; y &lt;a href="http://www.amperis.com/productos/camaras-efecto-corona/"&gt;cámaras de efecto corona&lt;/a&gt; transportadas en helicóptero o por un equipo de operarios a pie. &lt;span style="font-weight: bold;"&gt;Se mide así la temperatura de las instalaciones, lo que permite detectar aquellos puntos que mantienen temperaturas inadecuadamente altas (puntos calientes) y evaluar el rendimiento que tendrán ante una posible punta de demanda de electricidad.&lt;/span&gt; &lt;/p&gt;&lt;p&gt; Por último, Iberdrola realizó trabajos de poda en los árboles que tienen más riesgo de contactar con las líneas por un importe de 250.000 euros. &lt;/p&gt;&lt;p&gt;  &lt;/p&gt;&lt;p&gt;OBJETIVOS Los objetivos de la compañía para el periodo 2008-2010 pasan por &lt;span style="font-weight: bold;"&gt;reducir en un 20% el tiempo de interrupción&lt;/span&gt; sobre los niveles actuales y renovar el parque de contadores (distribución), desarrollar instalaciones de 220 kV de carácter urbano (transporte) y ampliar la capacidad de regasificación de las plantas que tiene en Bilbao y en Sagunto así como la red de distribución de gas. &lt;/p&gt;&lt;p&gt; Iberdrola espera destinar a lo largo de los próximos tres años, si las condiciones reguladoras son las adecuadas, 2.000 millones euros (35 % sobre el trienio anterior) a, entre otras muchas actuaciones, la construcción de más de 5.800 kilómetros de líneas de baja, media, alta y muy alta tensión o la entrada en servicio o ampliación de más de 70 subestaciones. &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-366356331374688125?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/366356331374688125/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=366356331374688125' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/366356331374688125'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/366356331374688125'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/05/camaras-termograficas-para-mantener-en.html' title='Camaras termograficas para mantener en buen estado las instalaciones'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_liWG2cxeH1g/SCrENMA_mHI/AAAAAAAAAPw/1czBZCmKeJY/s72-c/345573_2.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6190438182783673472</id><published>2008-05-07T09:12:00.000-07:00</published><updated>2008-05-07T09:16:31.488-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='videomanual'/><category scheme='http://www.blogger.com/atom/ns#' term='telurometros'/><category scheme='http://www.blogger.com/atom/ns#' term='telurómetros'/><title type='text'>Uso del Telurometro</title><content type='html'>&lt;h3&gt;Video manual del uso del telurometro&lt;/h3&gt;&lt;br /&gt;&lt;br /&gt;&lt;object height="355" width="425"&gt;&lt;param name="movie" value="http://www.youtube.com/v/9ba-4L4zYMo&amp;amp;hl=zh_HK"&gt;&lt;param name="wmode" value="transparent"&gt;&lt;embed src="http://www.youtube.com/v/9ba-4L4zYMo&amp;amp;hl=zh_HK" type="application/x-shockwave-flash" wmode="transparent" height="355" width="425"&gt;&lt;/embed&gt;&lt;/object&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;¿Quieres saber más sobre el funcionamiento del &lt;/span&gt;&lt;a style="font-weight: bold;" href="http://www.amperis.com/productos/telurometros/"&gt;telurometro&lt;/a&gt;&lt;span style="font-weight: bold;"&gt;? En la sección &lt;/span&gt;&lt;a style="font-weight: bold;" href="http://www.amperis.com/productos/telurometros/"&gt;telurómetros&lt;/a&gt;&lt;span style="font-weight: bold;"&gt; de Amperis dispones de amplia información.&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6190438182783673472?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6190438182783673472/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6190438182783673472' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6190438182783673472'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6190438182783673472'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/05/uso-del-telurometro.html' title='Uso del Telurometro'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6736275649856830425</id><published>2008-04-27T22:43:00.000-07:00</published><updated>2008-04-27T22:46:42.116-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='microhmetros'/><category scheme='http://www.blogger.com/atom/ns#' term='micróhmetros'/><category scheme='http://www.blogger.com/atom/ns#' term='microhmetro'/><title type='text'>Microhmetros - Acerca de la corriente de prueba</title><content type='html'>&lt;h2&gt;Microhmetros - Acerca de la corriente de prueba&lt;/h2&gt;El valor de una resistencia de contacto primario (la resistencia entre dos terminales de cualquier polo de un interruptor) normalmente se mide antes de que se ponga el interruptor de circuito en servicio por primera vez y durante las inspecciones de mantenimiento. La resistencia de contacto es un valor que se especifica como una red para todas las clases de interruptores de circuito: de acuerdo con la IEC 56 (ahora IEC62271-100), este valor de resistencia se debe medir usando una corriente de prueba de entre 50A y el valor nominal de la corriente del interruptor. De acuerdo con la ANSI C 37.09, la corriente de prueba inferior es de 100A. Otras normas nacionales e internacionales especifican regulaciones similares.&lt;br /&gt;&lt;p&gt;Por lo regular, el fabricante define el valor de la corriente de prueba. La mayor parte de los fabricantes (ABB, Alstom, etc.) especifican la corriente de prueba en 200A. Algunos proveedores del servicio de energía tienen sus propias regulaciones (Vattenfall_Suecia mide la resistencia de contacto para los interruptores y desconecta los interruptores en 300A). Otros usan una corriente de prueba de 500A o 600A, en tanto que algunos no pasan de 100A.&lt;br /&gt;&lt;br /&gt;Opinamos que el valor de la corriente de prueba de 300A (a menudo, inclusive de 200A) es suficiente para una medición correcta y confiable.&lt;/p&gt;Si hay alguna duda sobre la precisión de la medición o la condición de los contactos, se puede repetir la medición usando el valor de corriente más alto. Nuestra experiencia demuestra el mejor resultado usando el modo CONT - medición de corriente continua con 200A a 300A con una duración de 50 segundos.&lt;br /&gt;&lt;p&gt;Las corrientes de prueba más altas aumentan la precisión, pero la corriente de prueba con más de 300A ofrece una mejora insignificante en la precisión. Las corrientes más altas requieren cables más grandes, que son pesados y hacen que el procedimiento de medición de la resistencia sea problemático y complicado, sin ninguna mejora considerable en el resultado.&lt;/p&gt;&lt;strong&gt;&lt;em&gt;Conclusión:&lt;/em&gt;&lt;/strong&gt;&lt;br /&gt;&lt;p&gt; &lt;strong&gt;Recomendamos la corriente de prueba de 300A&lt;/strong&gt;. Para la mayoría de las situaciones, la corriente de prueba de 200A es suficiente. En caso de dudas, repita la prueba usando el modo Cont con una medición con mayor duración con corrientes de 300A o 200A.&lt;br /&gt;&lt;br /&gt;Se recomienda usar 400A o 500A para situaciones en que se espera que la resistencia de contacto medida sea de menos de 20µO.&lt;/p&gt;&lt;br /&gt;&lt;h2&gt;&lt;a href="http://www.amperis.com/productos/microhmetros/" title="http://www.amperis.com/productos/microhmetros/" id="link_0"&gt;Microhmetro&lt;/a&gt;  - Declaración sobre la precisión&lt;/h2&gt;La precisión de los &lt;a href="http://www.amperis.com/productos/microhmetros/" title="http://www.amperis.com/productos/microhmetros/" id="link_1"&gt;Microhmetros&lt;/a&gt;  se define como ±(0,25% rdg + 0,25% FS) siempre que se satisfagan las dos condiciones siguientes:&lt;br /&gt;&lt;ul&gt;&lt;br /&gt;&lt;li&gt;que la corriente de la medición sea de por lo menos 100A &lt;/li&gt;&lt;br /&gt;&lt;br /&gt;&lt;li&gt;que el rango de la medición esté entre 100µO y 20mO&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;p&gt;Si la corriente es de menos de 100A, se puede establecer la precisión siguiendo la tabla siguiente:&lt;/p&gt;&lt;table cellpadding="0" width="50%"&gt;&lt;br /&gt;&lt;tbody&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Corriente de Prueba&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Error&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;50 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+1µΩ&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;20 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,5%+2µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;10 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;1%+5µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;/tbody&gt;&lt;br /&gt;&lt;/table&gt;No se recomienda la medición de resistencias por debajo de los 100µO con corriente de menos de 100A.&lt;br /&gt;&lt;p&gt;En el caso de una resistencia de entre 20µO y 100µO se define la precisión como sigue:&lt;/p&gt;&lt;br /&gt;&lt;table cellpadding="0" width="50%"&gt;&lt;br /&gt;&lt;tbody&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Corriente de Prueba&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Error&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;600 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+0,5µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;br /&gt;&lt;td&gt;500 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+0,6µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;400 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+0,7µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;300 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+0,8µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;200 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+0,9µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;100 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+1,0µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;/tbody&gt;&lt;br /&gt;&lt;/table&gt;&lt;br /&gt;&lt;p&gt;Para un espécimen con resistencia sobre 20mOhm, se define la precisión usando la tabla:&lt;/p&gt;&lt;table cellpadding="0" width="50%"&gt;&lt;br /&gt;&lt;br /&gt;&lt;tbody&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Corriente de    Prueba&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Error&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;50 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,25%+1µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;20 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,5%+2µΩ&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;10 A&lt;/td&gt;&lt;br /&gt;&lt;td&gt;1%+5µΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;/tbody&gt;&lt;br /&gt;&lt;/table&gt;&lt;br /&gt;&lt;p&gt;Si requiere una mayor precisión, necesita:&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;verificar la calibración del instrumento usando la Derivación de Prueba incluida antes de la prueba&lt;/li&gt;&lt;br /&gt;&lt;li&gt;usar siempre la máxima corriente disponible para un rango particular&lt;strong&gt;&lt;sup&gt;*&lt;/sup&gt;&lt;/strong&gt;&lt;/li&gt;&lt;br /&gt;&lt;br /&gt;&lt;li&gt;hacer dos mediciones en dos direcciones, la segunda medición con conexión invertida en la entrada de VS. Calcular el promedio de las dos mediciones.&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;p&gt;&lt;strong&gt;&lt;sup&gt;*&lt;/sup&gt;&lt;/strong&gt;La corriente máxima para un rango determinado depende del voltaje del suministro, longitud y sección transversal de los cables (resistencia del cable), así como del rango de medición máximo en la entrada del sensor de Voltaje. El  rango de medición máximo en la entrada del sensor de Voltaje es de 2.5V&lt;/p&gt;&lt;br /&gt;&lt;p&gt;En caso de que el instrumento no pueda alcanzar/generar la corriente de prueba preestablecida, la pantalla mostrará el valor de la corriente máxima lograda y el resultado. Este resultado es de la precisión más baja, de manera que recomendamos que se repita la prueba preseleccionando el primer rango de corriente más bajo.&lt;/p&gt;&lt;br /&gt;&lt;h2&gt;Micróhmetros - Acerca de los cables de corriente&lt;/h2&gt;&lt;br /&gt;&lt;p&gt;La selección de los cables de corriente depende de:&lt;/p&gt;&lt;ul&gt;&lt;br /&gt;&lt;li&gt;El tipo de instrumento&lt;/li&gt;&lt;br /&gt;&lt;li&gt;La amplitud de la corriente de prueba&lt;/li&gt;&lt;br /&gt;&lt;br /&gt;&lt;li&gt;La longitud del cable requerida para realizar la prueba&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;p&gt;Los &lt;a title="Micróhmetros" href="http://www.amperis.com/productos/microhmetros/"&gt;Micróhmetros&lt;/a&gt; son muy potentes y tal vez tienen la mayor potencia de salida en el mercado. Esto significa que nuestros Micróhmetros pueden generar la corriente preestablecida requerida aun con cables muy largos.&lt;/p&gt;&lt;p&gt;Un indicador que muestra la potencia de la salida de un instrumento es el voltaje de Carga en los contactos de la salida del instrumento con el valor de corriente requerido (FLV; &lt;em&gt;required current value&lt;/em&gt;). Por ejemplo, el instrumento puede producir:&lt;/p&gt;&lt;table cellpadding="0" width="50%"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Voltaje de Suministro&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Corriente de Salida&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Voltaje de Carga Total&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;230V AC&lt;/td&gt;&lt;br /&gt;&lt;td&gt;400A DC&lt;/td&gt;&lt;br /&gt;&lt;td&gt;5,0V DC&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;&lt;br /&gt;&lt;/td&gt;&lt;br /&gt;&lt;td&gt;300A DC&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;td&gt;6,0V DC&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;115V AC&lt;/td&gt;&lt;br /&gt;&lt;td&gt;400A DC&lt;/td&gt;&lt;br /&gt;&lt;td&gt;4,0V DC&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;&lt;br /&gt;&lt;/td&gt;&lt;br /&gt;&lt;td&gt;300A DC&lt;/td&gt;&lt;br /&gt;&lt;td&gt;4,8V DC&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;/tbody&gt;&lt;br /&gt;&lt;/table&gt;a) TAMAÑO DEL CABLE (sección transversal/grosor)&lt;br /&gt;&lt;p&gt;Para seleccionar un tamaño de cable, debe empezar desde la corriente de prueba requerida. Pongamos el ejemplo de una corriente de prueba de 300A y voltaje de suministro de 115V AC.&lt;/p&gt;La resistencia máxima de los cables y conductores de los interruptores de circuito de energía que se puede medir se calcula como la razón de FLV/Corriente&lt;br /&gt;&lt;p&gt;4,8V/300A = 16mO&lt;/p&gt;Si necesitamos cables con la longitud total de 15m (por ejemplo, 10m + 5m), entonces el tamaño recomendado sería de 35mm2. La resistencia total de los cables entonces es de 9mO. La resistencia del circuito medido (conductores  y contactos) normalmente es de alrededor de 1mO, haciendo que la resistencia del ciclo completo sea menor que el máximo calculado.&lt;br /&gt;&lt;p&gt;Si necesitamos cables con la longitud total de 20m (por ejemplo, 10m + 10m o 5m + 15m) entonces el tamaño recomendado sería de 2x5m, 35mm2 + cable de extensión de 2x5m, 50mm2. La resistencia total de los cables es de 10,2mO. La resistencia de los conductores y contactos, como se mencionó antes es del orden de 1mO, haciendo que el total esté dentro de los requerimientos.&lt;/p&gt;&lt;strong&gt;Tabla de resistencias de cable:&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;table cellpadding="0" width="50%"&gt;&lt;br /&gt;&lt;tbody&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Cables de Corriente&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;td&gt;&lt;strong&gt;Resistencia&lt;/strong&gt;&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x3m, 70mm2&lt;/td&gt;&lt;br /&gt;&lt;td&gt;0,9mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x5m, 70mm2&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;td&gt;1,5mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x5m, 50mm2&lt;/td&gt;&lt;br /&gt;&lt;td&gt;2,1mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x5 m, 35mm2&lt;/td&gt;&lt;br /&gt;&lt;td&gt;3,0mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x5m, 25mm2&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;td&gt;4,2mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x10m, 70mm2&lt;/td&gt;&lt;br /&gt;&lt;td&gt;3,0mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x10m, 50mm2&lt;/td&gt;&lt;br /&gt;&lt;td&gt;4,2mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x10m, 35mm2&lt;/td&gt;&lt;br /&gt;&lt;br /&gt;&lt;td&gt;6,0 mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;tr&gt;&lt;br /&gt;&lt;td&gt;1x10m, 25mm2&lt;/td&gt;&lt;br /&gt;&lt;td&gt;8,4 mΩ&lt;/td&gt;&lt;br /&gt;&lt;/tr&gt;&lt;br /&gt;&lt;/tbody&gt;&lt;br /&gt;&lt;/table&gt;&lt;em&gt;&lt;strong&gt;Conclusión:&lt;/strong&gt;&lt;/em&gt;&lt;br /&gt;&lt;p&gt; Con base en su situación particular o la aplicación más común, debe calcular la  longitud y la sección transversal de los cables que se van a usar. &lt;strong&gt;No compre cables largos y gruesos  que realmente no necesite&lt;/strong&gt;. Es probable que los cables pesen más que el mismo instrumento dado el bajo peso inherente del instrumento aun con una salida de potencia tan alta.&lt;/p&gt;&lt;br /&gt;&lt;h3&gt;b) TAMAÑO DEL CABLE - Longitud&lt;/h3&gt;&lt;p&gt;La mayoría de los clientes compra ambos cables del mismo largo, aunque uno puede ser ya sea de 3 o 5m  de largo. Es una práctica común conectar un cable a un punto de tierra cercano al interruptor. El otro cable, que puede ser más largo, se conecta al otro extremo del interruptor que se prueba y no se conecta a tierra. Nuestra experiencia demuestra que una combinación de un cable largo y uno corto (5m y 10m) funciona bien en la mayor parte de los casos.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;En el caso de las aplicaciones con cable más largo (de más de 2X5m), recomendamos adquirir cables de extensión. La combinación más, común es de 1x5m + 1x10m y se podría lograr con cables de corriente de 2x5m + cable de extensión de 1x5m. La combinación de cables de corriente de 2x5m + cables de extensión de 2X5m puede satisfacer casi todos los requerimientos (2x10m o 1x5m + 1x15m).&lt;br /&gt;&lt;br /&gt;Utilizando cables de extensión se pueden lograr varias combinaciones de longitud útiles. Es muy frecuente que sea suficiente usar sólo los cables básicos y en esas circunstancias, se debe evitar el uso de cables largos y pesados.&lt;/p&gt;&lt;p&gt;Empleando cables de extensión, es posible hacer una combinación en que los cables de corriente tienen la sección transversal más baja (es decir, 2x5m 25mm2) + cables de extensión de 1x5m 35mm2 o 2x5m 50mm2. La resistencia de contacto entre los cables de corriente y los cables de extensión es de menos de 100µO y no influiría en la resistencia total de la corriente llevando conductores de medición.&lt;/p&gt;&lt;p&gt;&lt;em&gt;&lt;strong&gt;Conclusión:&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;&lt;p&gt;En lugar de largos cables pesados y complicados, &lt;strong&gt;adquiera cables de corriente básicos (2x5m)&lt;/strong&gt;, que ofrecerán una aplicación ligera y sencilla la mayor parte de las veces y consiga los cables de extensión requeridos para situaciones especiales.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;fuente: &lt;a href="http://lacomunidad.elpais.com/instrumentacion-electrica/2008/4/23/microhmetro"&gt;http://lacomunidad.elpais.com/instrumentacion-electrica/&lt;/a&gt;&lt;br /&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6736275649856830425?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6736275649856830425/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6736275649856830425' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6736275649856830425'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6736275649856830425'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/04/microhmetros-acerca-de-la-corriente-de.html' title='Microhmetros - Acerca de la corriente de prueba'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-9118683903039859187</id><published>2008-03-13T05:10:00.000-07:00</published><updated>2008-03-13T05:29:33.947-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='infrarrojos'/><category scheme='http://www.blogger.com/atom/ns#' term='termografía'/><title type='text'>FAQ - Termografía</title><content type='html'>Nos han llegado muchas preguntas relacionadas con termografía, exponemos aquí las más numerosas, este post los actualizaremos a menudo:&lt;br /&gt;&lt;br /&gt;1 -P- &lt;em&gt;¿Por qué las cámaras termográficas a veces se ven en color y otras en blanco y negro?&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;-R- Las imágenes termográficas no tienen color en sentido estricto, se trata de colores ficticios que reflejan la intensidad de radiación en el espectro infrarrojo. De hecho, muchas cámaras termográficas permiten cambiar la paleta de colores dejando al usuario que escoja la que prefiera.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;2 -P- &lt;em&gt;¿A qué distancia funciona una cámara termográfica?&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;-R- No se puede dar una respuesta inmediata. Depende del tamaño del objeto, en función de un parámetro que se llama &lt;a href="http://www.amperis.com/productos/camaras-termograficas/#resolucion_espacial"&gt;resolución espacial&lt;/a&gt; [1] se define el tamaño mínimo que se ve a una determinada distancia.&lt;br /&gt;&lt;br /&gt;3 -P- &lt;span style="font-style: italic;"&gt;¿Pueden verse elementos subterráneos, (ej. un cable), con una cámara termográfica?&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;-R- Una &lt;a href="http://www.amperis.com/productos/camaras-termograficas/"&gt;cámara termográfica&lt;/a&gt; [2] permite ver un mapa de temperaturas de la superficie del suelo, si el cable no altera la temperatura de la superficie entonces no se podrá ver ni siquiera su traza.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;small style="font-style: italic;"&gt;[1] &lt;a href="http://www.amperis.com/productos/camaras-termograficas/#resolucion_espacial"&gt;http://www.amperis.com/productos/camaras-termograficas/#resolucion_espacial&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;[2] &lt;a href="http://www.amperis.com/productos/camaras-termograficas/"&gt;http://www.amperis.com/productos/camaras-termograficas/&lt;/a&gt;&lt;/small&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-9118683903039859187?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/9118683903039859187/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=9118683903039859187' title='3 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/9118683903039859187'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/9118683903039859187'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2008/03/faq-termografa.html' title='FAQ - Termografía'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>3</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6562216341246593365</id><published>2007-12-11T13:57:00.000-08:00</published><updated>2007-12-11T14:00:45.843-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='infrarrojos'/><category scheme='http://www.blogger.com/atom/ns#' term='calibración'/><category scheme='http://www.blogger.com/atom/ns#' term='IR'/><category scheme='http://www.blogger.com/atom/ns#' term='radiometría'/><category scheme='http://www.blogger.com/atom/ns#' term='calibrar'/><title type='text'>Calibracion equipos radiometricos</title><content type='html'>&lt;h2&gt;Calibración de equipos radiométricos&lt;/h2&gt;&lt;p&gt;Para garantizar la exactitud de medición, los radiómetros infrarrojos deben ser calibrados periódicamente. Aunque los termógrafos suelen discutir sobre la calibración, hay confusión en cuanto a su aplicación y su significado con respecto a los instrumentos radiométricos. En este artículo se analiza el arte y la ciencia de la calibración de instrumentos infrarrojos, recursos sobre calibración y el mantenimiento de registros que son trazables por estándares conocidos.&lt;/p&gt;&lt;h3&gt;Introducción: Historia de la Calibración&lt;/h3&gt;&lt;p&gt;Hace unos cuantos miles de años, los egipcios desarrollaron un sistema de medición trazable, hoy conocido como &lt;em&gt;&lt;a href="http://www.blogger.com/es.wikipedia.org/wiki/Metrolog%C3%ADa"&gt;Metrología&lt;/a&gt;&lt;/em&gt;. En los días de los reyes y faraones, un bloque de granito medido por un faraón desde el antebrazo hasta la punta de su dedo índice, más el ancho de la palma, se convirtió en referencia para la longitud (&lt;em&gt;The Royal Egyptian Cubit&lt;/em&gt;). Arquitectos, artesanos e ingenieros constructores de pirámides, tumbas y templos usaron desde entonces esta referencia. El resultado de esta medida y la trazabilidad del &lt;em&gt;The Royal Egyptian Cubit&lt;/em&gt; es todavía hoy, una de las grandes maravillas de la historia. Las pirámides se construyeron con un porcentaje de error de +- 0,05%. Esto significa que por cada 125 pies, los constructores Egipcios fallaron en !menos de una pulgada! Se podría observar que, si los titulares de la &lt;em&gt;The Royal Egyptian Cubit&lt;/em&gt; no llevasen su copia semanal para comparar con el maestro, ¡la falta sería pena de muerte! (Si está interesado en esta historia y dar crédito, por favor, visite: &lt;a href="http://www.ncsli.org/misc/cubit.cfm"&gt;http://www.ncsli.org/misc/cubit.cfm&lt;/a&gt; (En inglés)). &lt;/p&gt;&lt;h3&gt;¿Qué es la calibración de un instrumento y para qué sirve?&lt;/h3&gt;&lt;br /&gt;&lt;img src="http://4.bp.blogspot.com/_liWG2cxeH1g/R18GF4Mj6dI/AAAAAAAAAOQ/ryuHVi57Kn0/s200/calibracion-equipo-termografico.jpg" alt="cámara termográfica calibración amperis" longdesc="calibración de equipo termográfico infrarrojo" style="float: left; margin-right: 3px;" height="198" width="212" /&gt;&lt;p&gt;La Calibración de un instrumento es el acto de comparar las unidades fundamentales de medida del instrumento con otro instrumento. Esta comparación de instrumentos es capaz de dar una lectura más precisa del mismo estímulo medido y que ha sido comparado con un instrumento más preciso. Esta cadena cada vez más estricta de comparaciones está sujeta a organismos nacionales o internacionales. En los EE.UU., este organismo sería el Instituto Nacional de Normas y Tecnología (NIST).&lt;/p&gt;&lt;br /&gt;&lt;p&gt;El NIST utiliza los fenómenos naturales de la física para establecer las unidades de medida. La medición de la temperatura incorpora el uso de la norma 100 ohmios .0385 &lt;em&gt;Detectores de Resistencia de Platino&lt;/em&gt; "&lt;em&gt;Platinum Resistance Detectors" &lt;/em&gt;(SPRTD o SRTD), en relación con el punto de congelación de ciertos metales o el &lt;em&gt;triple punto de agua&lt;/em&gt; (fenómeno de la naturaleza que pocos elementos o compuestos comparten, el punto de temperatura/presión en el que el agua destilada es sólida / líquida o gaseosa). Para las mediciones de energía radiante, un apéndice ambiental se añadirá al detector de temperatura de contacto incorporado en un casi perfecto radiador de materiales. Estas fuentes se refieren a las normas primarias. Una norma primaria se considera como la medida exacta que usted va a obtener.&lt;/p&gt;&lt;p&gt;Cuando las precisiones son combinadas para formar un total de incertidumbre para su instrumento, el resultado se utiliza para medir un estímulo con un grado de certidumbre en su medición. Esto le proporciona la oportunidad de obtener un punto de medición capaz de ser repetido (cuando se toma en condiciones similares) en otro momento y en cualquier lugar del planeta. Esto establece, además, una base para el esperado acontecimiento, por ejemplo, los cubitos de hielo comenzarán a descongelarse aproximadamente a 32 grados F por encima de los 0m. a nivel del mar. &lt;/p&gt;&lt;p&gt;Cuando se habla de calibración de cualquier instrumento, los términos exactitud, tolerancia e incertidumbre son a menudo intercambiables y similares. Pero no lo son. Estos términos pueden explicarse detalladamente o simplemente decir que son temas en sí mismos. Para el propósito de esta presentación, la exactitud es una declaración de los posibles límites de error para un determinado parámetro de un instrumento en condiciones específicas. El total de errores sólo para ese instrumento sería la tolerancia del instrumento. La mayoría de los instrumentos de medida tendrán varios errores que pueda afectar a las mediciones mostradas. Cuando se combinan estos errores, primero con errores del mismo instrumento (los relacionados directamente con un instrumento, la tolerancia), y luego con los errores totales de los instrumentos adicionales utilizados conjuntamente con un valor visualizado (es decir, un instrumento de bucle), el resultado es una incertidumbre total de lectura.&lt;/p&gt;&lt;p&gt;Quizás un ejemplo podría aclararlo: La presión de aire recomendada para una marca de neumáticos en un modelo de vehículo. Un boletín informa a los usuarios de la presión anterior y de la presión recomendada. Pero, ¿cómo garantizar al  usuario que la presión que se lee en otro continente con un instrumento diferente, es correcta? La respuesta es una ciencia conocida como &lt;a href="http://www.blogger.com/es.wikipedia.org/wiki/Metrolog%C3%ADa"&gt;&lt;em&gt;Metrología&lt;/em&gt;&lt;/a&gt;; que son los sistemas de registro y calibración necesarios para ofrecer garantías de una trazabilidad exacta de un instrumento (para NIST u otra organización).&lt;/p&gt;&lt;p&gt;Otro ejemplo podría ser la silla en la que está Ud. sentado. Es probable que las piezas utilizadas para construir y tapizar o manufacturar la silla, se fabricasen en más de un sitio. ¿Cómo es que encajan tan bien las piezas, la pintura o el cromado, o la impresión del embalaje es tan uniforme? y seguro que ha pasado por un buen número de contenedores y máquinas. La respuesta está en repetidas mediciones exactas de instrumentos de intercambio de la misma cadena de medir la precisión.&lt;/p&gt;&lt;p&gt;Ahora bien, ¿por qué calibrar su radiometría? La respuesta a esta pregunta radica en su uso del equipo:&lt;br /&gt;&lt;br /&gt;Si usted:&lt;br /&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;A. Usa temperaturas específicas relacionadas con IR&lt;/li&gt;&lt;br /&gt;&lt;li&gt;B. Usa temperaturas relacionadas Delta IR&lt;/li&gt;&lt;br /&gt;&lt;li&gt;C. Usa imágenes con sus correspondientes matices que implican temperaturas de la imagen visualizada&lt;/li&gt;&lt;br /&gt;&lt;li&gt;D. Usa comparativas IR a otros datos relacionados con la instrumentación&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;p&gt;Usted seguramente sea un termógrafo.&lt;br /&gt;&lt;br /&gt;Si usted es termógrafo, tendrá mayor información térmica relacionada correctamente que sólo puede ser realizada con &lt;strong&gt;instrumentos calibrados&lt;/strong&gt;. Los instrumentos NO-Calibrados, a veces son lo suficientemente buenos para proporcionar una indicación de que podría ser un objeto caliente o frío. El hecho es que se no se puede demostrar.&lt;/p&gt;&lt;p&gt;Analizar sus resultados es la razón fundamental para calibrar. Si el instrumento está calibrado y el cliente (o su abogado) se pregunta: "¿Está el objeto en cuestión tan caliente o frío como usted afirma?" La respuesta sencilla es sí. La respuesta compleja incluiría un grado de tolerancia.&lt;/p&gt;&lt;h3&gt;La exactitud de las cámaras y la calibración estándar&lt;/h3&gt;&lt;br /&gt;&lt;img src="http://2.bp.blogspot.com/_liWG2cxeH1g/R18IBYMj6fI/AAAAAAAAAOg/z4ajZlvLLqo/s320/calibracion-termografica-infrarroja.jpg" alt="cámara termográfica calibración amperis" longdesc="calibración de una cámara termográfica infrarroja" style="float: right; margin-left: 3px;" height="329" width="190" /&gt;&lt;p&gt;En la declaración básica de la exactitud para sus imágenes no se incluirán (por norma general) las imprecisiones de su equipo. Se suele decir que la temperatura será visita +- algunos valores (a menudo 2% de la escala máxima de lectura), hasta un conjunto de temperatura y algunos valores más por encima de esta temperatura. La exactitud de la calibración del instrumento debe ser de al menos 1 / 3 a 1 / 4 de su instrumento de precisión (es decir,  un 2% por instrumento, una norma debe ser del 0,67 al 0,5% de plena escala de lectura). Como ejemplo, considere la posibilidad de:&lt;br /&gt;&lt;br /&gt;Una cámara de precisión es de +- 2 ° C a 100 ° C o +- 2% de la lectura. Con este valor declarado, en decir, 250 grados C, su instrumento puede leer actualmente de 245 a 255 grados C (+- 5 grados C).&lt;/p&gt;&lt;br /&gt;&lt;p&gt;Cuando se trata de la temperatura radiante, este tipo de exactitud (es decir, 0,5%) es difícil de obtener. La razón es que la Emisividad (E), Reflectividad (R) y Transmisión (T) tienden a inducir errores iguales o superiores al 2% del valor mostrado. Por esta razón, las normas primarias de energía radiante se suelen realizar en laboratorio. Estas normas tienen por objeto reducir en gran medida los errores ERT. R y T en estas normas será insignificante y E será 0,995 y como máximo, en la mayoría de los casos. Estas normas se fijan en sí mismas (por lo general) +- 1 a 2% o menos de la lectura o máximo de la escala. Es importante señalar que estas normas a menudo derivan su valor de la temperatura y la refrigeración de control de termometría incorporada y, debido a esto, puede ser calibrada a una mayor tolerancia, de ser necesario.&lt;/p&gt;&lt;h3&gt;Certificación de Calibración&lt;/h3&gt;&lt;p&gt;La &lt;strong&gt;Certificación de la calibración&lt;/strong&gt; se destina a la calidad y a proporcionar un instrumento jurídico para un fabricante, usuario o cliente para garantizar los valores de una realidad física. En su forma más simple, la certificación es un documento destinado a ser trazable, para: La exactitud repetible en las declaraciones, la identidad de instrumentación, los titulares de instrumentación y los ejecutantes de la calibración&lt;/p&gt;&lt;h3&gt;Calibración estándar para las Cámaras de infrarrojos / Termográficas&lt;/h3&gt;&lt;p&gt;Si envía su equipo de &lt;a href="http://www.amperis.com/productos/camaras-termograficas/"&gt;camaras termograficas infrarrojas&lt;/a&gt; a calibrar, hay probabilidades de que el cuerpo negro se use y el rango de costos utilizados, entre aproximadamente $ 500,00 los nuevos, hasta $ 1500,00 o más, más el costo de los certificados de trazabilidad. Entonces, &lt;strong&gt;¿cómo se puede calibrar un instrumento en casa o la oficina, por ejemplo, a un menor costo?&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Una de las técnicas más comunes es congelar agua destilada o simplemente llevarla a ebullición, y observar la temperatura de la nave con su radiometría. Para ello se requiere:&lt;/p&gt;&lt;ol&gt;&lt;li&gt;Garantía de que su nave es lo suficientemente grande como para asegurar que el tamaño de su radiometría es inferior a la superficie observada.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Que la nave de superficie observada por su radiometría es plana y perpendicular al plano del observador.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Que se puede determinar razonablemente que la nave de superficie &lt;em&gt;S&lt;/em&gt; y en el ejercicio de sus competencias de nivel II.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Que la iluminación y otras fuentes de calor impactan mínimamente (RT).&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Que use contacto trazable termométrico para garantizar la espera de lectura&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;&lt;strong&gt;Notas:&lt;/strong&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;Mantenga sus registros como cuando hace el mantenimiento de los informes para sus clientes. Tendrá que ejercitar la repitibilidad entre la obtención de lecturas anuales, a fin de examinar el dónde, cuándo y cómo desempeñar la calibración. &lt;/li&gt;&lt;/ul&gt;&lt;h4&gt;¿Con qué frecuencia se debe calibrar o validar un instrumento?&lt;/h4&gt;&lt;p&gt;Normalmente, los instrumentos IR (Infrarrojos) son calibrados o verificados  anualmente. Un simple y único punto de validación de su radiometría, a menudo se realiza antes de realizar una exploración. La validación es un concepto para garantizar, y normalmente no requiere tanto tiempo como en la calibración.&lt;/p&gt;&lt;h4&gt;El Costo de Calibrar&lt;/h4&gt; &lt;p&gt;Calibrar radiometría mediante terceros, como un laboratorio de calibraciones o el fabricante del laboratorio de calibración, es costoso. Los fabricantes suelen ser la única fuente de corrección de radiometría. Esto se debe a la utilización de software propietario en la radiometría. Las calibraciones de los laboratorios que no son del fabricante sólo serán capaces de proporcionar pruebas de que su trazabilidad radiométrica está dentro del fabricante o sus especificaciones.&lt;/p&gt; &lt;p&gt;Si tiene intención de gastar más dinero para obtener su propio cuerpo negro (altamente recomendable si usa Termografía de Nivel II), algunas fuentes han sido enumeradas al final de este artículo.&lt;/p&gt; &lt;p&gt;Una descripción más completa de la trazabilidad y una excelente fuente de los términos clave en la calibración son proporcionados por el NIST en:&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ts.nist.gov/traceability/"&gt;http://ts.nist.gov/traceability/&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://ts.nist.gov/traceability/suppl_matls_for_nist_policy_rev.%20HTM"&gt; http://ts.nist.gov/traceability/suppl_matls_for_nist_policy_rev. HTM&lt;/a&gt;&lt;/p&gt;&lt;h3&gt;Referencias&lt;/h3&gt;&lt;ul&gt;&lt;li&gt;1. &lt;a href="http://www.amperis.com/"&gt;Amperis&lt;/a&gt; - Instrumentos de medida - &lt;a href="http://www.amperis.com/productos/camaras-termograficas/"&gt;Cámaras Termográficas&lt;/a&gt;&lt;/li&gt;&lt;br /&gt;&lt;li&gt;2. Web del Instituto Nacional de Estandares y Tecnología de EEUU (Inglés): http://www.nist.gov&lt;/li&gt;&lt;br /&gt;&lt;li&gt;3. ANSI/NCSL Z540-2-1997 American National Standard for Expressing Uncertainty, US Guide to the Expression of Uncertainty in Measurement&lt;/li&gt;&lt;br /&gt;&lt;li&gt;4. Infraspection Institute’s Level II Certified Infrared Thermographer Reference Manual&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6562216341246593365?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6562216341246593365/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6562216341246593365' title='2 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6562216341246593365'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6562216341246593365'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/12/calibracion-equipos-radiometricos.html' title='Calibracion equipos radiometricos'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_liWG2cxeH1g/R18GF4Mj6dI/AAAAAAAAAOQ/ryuHVi57Kn0/s72-c/calibracion-equipo-termografico.jpg' height='72' width='72'/><thr:total>2</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-4947358560018364380</id><published>2007-11-25T13:53:00.000-08:00</published><updated>2007-11-25T14:20:05.087-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='infrarrojos'/><category scheme='http://www.blogger.com/atom/ns#' term='termografía'/><category scheme='http://www.blogger.com/atom/ns#' term='SARS'/><title type='text'>SARS y Termografia</title><content type='html'>&lt;h2&gt;El &lt;acronym title="Síndrome Agudo Respiratorio Severo" lang="es"&gt;SARS&lt;/acronym&gt; y la termografía&lt;/h2&gt; &lt;p&gt;Desde que el &lt;acronym title="Síndrome Agudo Respiratorio Severo" lang="es"&gt;SARS&lt;/acronym&gt; se diagnosticó por vez primera en febrero de 2003 ha habido una gran información acerca de cómo las cámaras termográficas contribuían a detectar personas infectadas por SARS.&lt;/p&gt; &lt;p&gt;Esfuerzos recientes para controlar la propagación del &lt;em&gt;Síndrome Agudo Respiratorio Severo&lt;/em&gt; (SARS) han impulsado a las autoridades sanitarias a desarrollar procesos de detección masivos, principalmente para los pasajeros de las aerolíneas.&lt;/p&gt;&lt;p&gt;Debido a que uno de los síntomas son las fiebres elevadas, rápidamente se propuso el emplear cámaras infrarrojas para identificar personas infectadas por el SARS a su paso por los aeropuertos. Si bien la termografía infrarroja tiene muchas ventajas para medir la temperatura corporal hay muchas variables, humanas, ambientales y  tecnológicas que pueden afectar la precisión.&lt;/p&gt; &lt;h3&gt;¿Qué es el SARS?&lt;/h3&gt;&lt;br /&gt;&lt;img style="float: left; margin-right: 5px;" src="http://2.bp.blogspot.com/_liWG2cxeH1g/R0n0SpiMSNI/AAAAAAAAAOA/RuGPzjHLNcs/s320/mascarilla-sars.jpg" alt="mascarilla sasr" /&gt;&lt;br /&gt;&lt;p&gt;El Síndrome Agudo Respiratorio Severo (SARS) es una recientemente descubierta y pontecialmente  letal enfermedad humana. Desde su reconocimiento inicial en febrero de 2003, resultaron infectadas 8200 personas de las cuales 735 murieron. De acuerdo con la &lt;acronym title="Organización Mundial de la Salud" lang="es"&gt;OMS&lt;/acronym&gt; se estima la tasa de mortalidad en el 15%. Sin embargo, esta tasa supera el 50% en personas mayores de 65 años. La rápida propagación de la enfermedad llevó a la &lt;acronym title="Organización Mundial de la Salud" lang="es"&gt;OMS&lt;/acronym&gt; a etiquetar el &lt;em&gt;SARS&lt;/em&gt; como &lt;em&gt;“la primera enfermedad infecciosa aparecida en el siglo XXI”&lt;/em&gt;.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;El &lt;em&gt;SARS&lt;/em&gt; ha demostrado su rápida propagación merced a las rutas aéreas internacionales. Desde que fue descubierta en Hanoi, Vietnam, el &lt;em&gt;SARS&lt;/em&gt; se extendió mundialmente a lo largo de las rutas aéreas y se ha informado de casos en los 6 continentes. Todavía queda mucho por saber del &lt;em&gt;SARS&lt;/em&gt;, se cree que se origina por un virus de la familia &lt;em&gt;coronavirus&lt;/em&gt;, del cual todavía no hay vacuna ni tratamiento.&lt;/p&gt; &lt;p&gt;De acuerdo con los distintos centros de control y prevención de enfermedades la principal vía de contagio del &lt;em&gt;SARS&lt;/em&gt; es el contacto entre personas. La mayor parte de de casos de &lt;em&gt;SARS&lt;/em&gt; se dieron en personas que cuidaban o vivían con afectados por el &lt;em&gt;SARS&lt;/em&gt;, o que habían tomado contacto con humores infectados (por ejemplo secreciones respiratorias).&lt;/p&gt; &lt;p&gt;El &lt;em&gt;SARS&lt;/em&gt; comienza con una fiebre superior a 38ºC, otros síntomas son las cefaleas, sensación de malestar general y dolores corporales. Después de 2 a 7 días los afectados de &lt;em&gt;SARS&lt;/em&gt; desarrollan un catarro y tienen problemas respiratorios.&lt;/p&gt;&lt;br /&gt;&lt;h2&gt;¿Pueden las cámaras termográficas utilizarse para detectar el SARS?&lt;/h2&gt; &lt;p&gt;A pesar de que las cámaras termográficas se utilizaron de forma generalizada en los aeropuertos  internacionales de Asia debe decirse lo siguiete:&lt;/p&gt; &lt;img style="float: right; margin-left: 5px;" alt="calor corporal fiebre vista con termografía" src="http://1.bp.blogspot.com/_liWG2cxeH1g/R0n0mZiMSOI/AAAAAAAAAOI/u19Ky3VU3Rk/s200/sars-fever-infrared.gif" /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;No hay protocolos de cómo debe medirse la temperatura corporal sin termómetros de contacto.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;No hay datos que sugieran la correlación entre la temperatura de la piel y la corporal&lt;/li&gt;&lt;br /&gt;&lt;li&gt;La mayor parte de cámaras infrarrojas carecen de la precisión y resolución necesaria para la diagnosis médica.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Hay muchas variables que afectan la precisión de la medida de la temperatura incluidas las condiciones ambientales, las condiciones del equipo y de la propia persona cuya temperatura corporal se quiere medir.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Una elevada temperatura corporal no certifica que una persona tiene &lt;em&gt;SARS&lt;/em&gt;, los diagnósticos los debe llevar a cabo personal médico cualificado.&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;br /&gt;&lt;p&gt;Sepa más sobre &lt;strong&gt;termografía&lt;/strong&gt; en la sección &lt;a href="http://www.amperis.com/productos/camaras-termograficas/"&gt;Cámaras termográficas&lt;/a&gt; de &lt;a href="http://www.amperis.com/"&gt;amperis.com&lt;/a&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-4947358560018364380?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/4947358560018364380/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=4947358560018364380' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4947358560018364380'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4947358560018364380'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/11/sars-y-termografia.html' title='SARS y Termografia'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_liWG2cxeH1g/R0n0SpiMSNI/AAAAAAAAAOA/RuGPzjHLNcs/s72-c/mascarilla-sars.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-1182060573428889394</id><published>2007-10-19T13:56:00.000-07:00</published><updated>2007-10-19T15:10:03.513-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='infrarrojos'/><category scheme='http://www.blogger.com/atom/ns#' term='plagas'/><category scheme='http://www.blogger.com/atom/ns#' term='termografía'/><category scheme='http://www.blogger.com/atom/ns#' term='termitas'/><title type='text'>Control de plagas insectos: Termografía</title><content type='html'>&lt;h3 style="text-align: center;"&gt;Los infrarrojos como herramienta profesional en el control de plagas&lt;/h3&gt;&lt;h4 style="text-align: center;"&gt;Resumen&lt;/h4&gt; &lt;p&gt;Los materiales de construcción han mejorado cuantitativamente y la capacidad para encontrar plagas se ha dificultado, ya que los nuevos materiales de construcción dificultan la detección de plagas.&lt;br /&gt;En los últimos años, la industria de plagas se ha percatado de que la termografía de infrarrojos puede ayudar, y mucho, en la detección de infestaciones de plagas, detectando la humedad latente de las estructuras. En este artículo se analiza la utilización de termografía para detectar patrones térmicos asociados a la infestación de insectos, la comprobación de los datos y dificultades especiales relacionadas con el proceso de observación.&lt;/p&gt;&lt;p&gt;&lt;b&gt;Historia&lt;/b&gt;&lt;/p&gt;&lt;p&gt;El control de plagas existe desde el principio de la humanidad. Originariamente, nuestros antepasados, se higienizaban continuamente para quitarse de encima a los insectos. Esencialmente, el control de plagas de insectos se trata de una actividad que se basa en la vista, porque si se pueden ver, se puede acabar con ellos.&lt;br /&gt;De esta manera, el hombre se tuvo que especializar en el control de plagas de insectos.&lt;br /&gt;La profesión se expandió y avanzó.&lt;br /&gt;&lt;br /&gt;El uso de productos químicos se convirtió en uno de las principales soluciones. Una vez se localizaba la plaga, el uso de productos químicos era la respuesta. La Industria descubrió una amplia variedad productos químicos que tenían gran éxito en el control de plagas, sin embargo, algunos de estos productos químicos, como el DDT, producen graves efectos secundarios como mutaciones y desintegración de cadenas de ADN, así como una progresiva resistencia de las plagas a los distintos productos químicos.&lt;/p&gt;&lt;p&gt;Llegaban los años 80 y la población de plagas comenzaba nuevamente a expandirse. Los profesionales de plagas, sin embargo, aún se basaban en la vista para localizar las plagas.&lt;/p&gt;&lt;p&gt;&lt;img style="float: left; margin-right: 5px;" src="http://3.bp.blogspot.com/_liWG2cxeH1g/Rxkgo0ZYX_I/AAAAAAAAAIM/Sp5s22PaXMA/s320/termitas.jpg" alt="plaga de termitas" height="156" width="200" /&gt;Los avances técnicos de la construcción, proporcionaron nuevos hábitos y fuentes de alimento para los insectos. Las placas de yeso han sustituido al torno y al yeso, proporcionando resistencia uniforme y facilitando la instalación, pero, por desgracia, se han convertido en una gran fuente de alimento para los insectos que se alimentan de celulosa, como las termitas.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;Las pequeñas aberturas pueden permitir la entrada de pequeñas termitas aladas que pueden convertirse en una reina termita capaz de crear una colonia de millones de termitas o permitir la entrada de otras plagas de insectos como hormigas. Algunas plagas como las abejas no necesitan aperturas hechas por el hombre o por la contracción y dilatación natural de los materiales, sino que crean su propia entrada penetrando el material.&lt;br /&gt;&lt;br /&gt;Las plagas de insectos viven prácticamente ocultas a la vista y casi siempre son descubiertas cuando salen de su escondite buscando comida.&lt;/p&gt;&lt;h3&gt;Uso termografía como herramienta de detección de plagas&lt;/h3&gt;&lt;p&gt;Hace unos años, un colega que trabaja en la industria de control de plagas le preguntó a un vendedor de cámaras de infrarrojos si podría encontrar termitas con la cámara.&lt;br /&gt;&lt;br /&gt;Iniciaron numerosos ensayos con diversas cámaras y se dieron cuenta de que cuando visualizaban el interior de edificios plagados, se encontraba una refrigeración anómala. Existe una correlación entre la presencia de humedad y la posible presencia de plagas de insectos. También se descubrió que cuando observaban anomalías en las paredes o estructuras de madera, los defectos mostrados tenían una alta correlación con el daño que se había producido o se estaba produciendo, de nuevo, por las termitas. En ambos casos, las anomalías no eran visibles a simple vista.&lt;br /&gt;&lt;br /&gt;Con resultados muy positivos, la utilización de cámaras termográficas y de infrarrojos se convirtió en una herramienta clave en el tratamiento de infestaciones de termitas. Hoy en día, una cámara de imágenes térmicas infrarroja es una herramienta casi imprescindible cuando estamos ante una plaga.&lt;/p&gt;&lt;p style="text-align: center;"&gt;&lt;img src="http://1.bp.blogspot.com/_liWG2cxeH1g/RxkhHUZYYAI/AAAAAAAAAIU/YCYHoP-Qhy8/s320/conductos-termitas-infrarrojos.jpg" alt="conductos de termitas vistos con infrarrojos" height="175" width="250" /&gt;&lt;br /&gt;&lt;span&gt;Conductos de termitas vistos con infrarrojos&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;p style="text-align: center;"&gt;&lt;img src="http://2.bp.blogspot.com/_liWG2cxeH1g/RxkhRkZYYBI/AAAAAAAAAIc/rIO1k_ot3Vs/s320/termitas-techos.jpg" alt="termitas en el techo vistas con cámaras termográfica" height="175" width="250" /&gt;&lt;br /&gt;&lt;span&gt;Termitas en el techo vistas con cámaras termográfica&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;El uso de cámaras de infrarrojos como herramienta de control de infestaciones de plagas en la industria difiere de su uso para la inspección de circuitos eléctricos, inspección de materiales refractarios o de la inspección de máquinas o equipos. En la mayoría de estos casos, las emisiones térmicas de alta temperatura y de las imágenes de infrarrojos son fácilmente evidentes.&lt;br /&gt;&lt;p&gt;Por otra parte, las inspecciones que utilizan imágenes infrarrojas en control de plagas consisten casi en su totalidad en emisiones bajas o muy cercanas a la temperatura ambiente con cambios a veces muy sutiles. No sólo se necesita el ojo experto de un termógrafo, sino también una comprensión, análisis e interpretación apropiados de las imágenes Infrarrojas. Entender los principales factores que están asociados con los problemas de plagas de insectos es requisito absoluto. Conocer y entender otros factores que se asocian con otras plagas, problemas tales como matices estacionales y regionales también conducen a la correcta interpretación y el análisis de las imágenes.&lt;/p&gt;&lt;p&gt;Cualquier termógrafo que preste servicios en la lucha contra las plagas debe ser consciente de que en una gran mayoría de los casos, las anomalías pueden ser muy pequeñas y pueden ser fácilmente pasadas por alto.&lt;br /&gt;&lt;br /&gt;Localizar una infestación de termitas en su primera etapa, podría ahorrar miles e incluso decenas de miles de euros en daños. Por otra parte, la localización de tóxicos derivados de estas plagas puede prevenir enfermedades.&lt;/p&gt;&lt;h3&gt;Usos adicionales de la termografía en el control de plagas&lt;/h3&gt;&lt;p&gt;La termografía es de gran ayuda para localizar roedores y nidos de pequeños animales dentro de las paredes o estructuras, dado que esas criaturas son de sangre caliente. El proceso de detección de plagas incluye el examen de elementos tales como paneles eléctricos, cañerías, y no es extraño encontrar problemas eléctricos como cables y circuitos defectuosos, conexiones sueltas o escapes.&lt;/p&gt;&lt;p&gt;Mientras se realice la inspección, pueden aparecer defectos en el aislamiento, filtraciones de aire del exterior, conductos agrietados, pérdidas de frio y calor.&lt;/p&gt;&lt;p&gt;Como el uso de imágenes térmicas permite ver el interior de las estructuras, el uso de estos aparatos es una herramienta esencial para localizar los lugares apropiados para los tratamientos químicos que acabarán con la plaga. Si se deja sin tratar una zona, puede convertirse en el lugar donde la plaga pueda sobrevivir.&lt;/p&gt;&lt;p&gt;Como parte del programa de tratamiento de plagas, son necesarios dos factores para un tratamiento de éxito:&lt;/p&gt;&lt;ol&gt;&lt;br /&gt;&lt;li&gt;Primero, si hay un factor, como puede ser la humedad, que proporciona condiciones favorables, ese factor debe ser eliminado. El uso de imágenes térmicas confirmará que el problema de la humedad ha sido resuelto.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Segundo, una vez que se ha efectuado el tratamiento, hay que confirmar la efectividad del tratamiento. La imagen térmica juega un papel muy importante en el proceso de confirmación.&lt;/li&gt;&lt;br /&gt;&lt;/ol&gt;&lt;h3&gt;Comprobación de datos.&lt;/h3&gt;&lt;p&gt;En el proceso de inspección de plagas es importante entender que el proceso de detección también incluye la verificación de los datos y hallazgos. Las imágenes digitales e infrarrojas deben ser grabadas. El uso de equipo adicional para cerciorarse de la presencia o no de la supuesta plaga es un deber fundamental.&lt;br /&gt;&lt;/p&gt;&lt;h3&gt;Desafios especiales&lt;/h3&gt;&lt;p&gt;El exterminador de plagas se encuentra con desafíos inusuales, algunos de los cuales deberían ser tratados en profundidad en otro momento, sin embargo, ciertos retos deben ser mencionados:&lt;/p&gt;&lt;ul&gt;&lt;br /&gt;&lt;li&gt;El control de plagas por termografia debería ser considerado como una especialidad. Es más fácil utilizar la termografia si se tiene experiencia en el campo de la exterminación.&lt;br /&gt;&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Pueden existir problemas estructurales. En las zonas donde existe actividad de termitas,  puede haber fallos estructurales, el inspector debe tener conocimiento de esos problemas o fallos.&lt;br /&gt;&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;em&gt;Artículo de Ian Donovan, Director de prevención predictiva de &lt;a href="http://www.amperis.com/" title="Amperis.com - Especialistas en termografía"&gt;Amperis.com&lt;/a&gt;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;Sepa más en la sección de &lt;a href="http://www.amperis.com/productos/camaras-termograficas/" title="Cámaras Termográficas Amperis.com"&gt;Cámaras termográficas&lt;/a&gt; de Amperis.&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-1182060573428889394?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/1182060573428889394/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=1182060573428889394' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1182060573428889394'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1182060573428889394'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/10/los-infrarrojos-como-herramienta.html' title='Control de plagas insectos: Termografía'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_liWG2cxeH1g/Rxkgo0ZYX_I/AAAAAAAAAIM/Sp5s22PaXMA/s72-c/termitas.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-770325838378678680</id><published>2007-10-08T07:33:00.001-07:00</published><updated>2007-10-08T07:33:26.008-07:00</updated><title type='text'>Amperis AirCam</title><content type='html'>&lt;div xmlns='http://www.w3.org/1999/xhtml'&gt;&lt;p&gt;&lt;object height='350' width='425'&gt;&lt;param value='http://youtube.com/v/I1i1ihzAWQU' name='movie'/&gt;&lt;embed height='350' width='425' type='application/x-shockwave-flash' src='http://youtube.com/v/I1i1ihzAWQU'/&gt;&lt;/object&gt;&lt;/p&gt;&lt;p&gt;Imagen tomada desde helicóptero con cámara AirCAM de Amperis&lt;/p&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-770325838378678680?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/770325838378678680/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=770325838378678680' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/770325838378678680'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/770325838378678680'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/10/amperis-aircam.html' title='Amperis AirCam'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6747872199407285579</id><published>2007-10-01T11:23:00.000-07:00</published><updated>2007-10-01T11:47:18.301-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='cámaras térmicas'/><category scheme='http://www.blogger.com/atom/ns#' term='termografía'/><title type='text'>Termografia: Ventajas</title><content type='html'>&lt;h4&gt;Ventajas de la Termografía&lt;/h4&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;Teoría:&lt;/strong&gt;Cuando la corriente eléctrica atraviesa un conductor se genera calor. Muchos defectos eléctricos vienen precedidos de una subida de la temperatura hasta varias semanas antes de que se genere un problema.&lt;/p&gt;&lt;br /&gt;   &lt;p align="center"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/camaras-termograficas/" title="Enlace externo a sección de Termografía de Amperis.com"&gt;&lt;img style="cursor: pointer;" src="http://1.bp.blogspot.com/_liWG2cxeH1g/RwE8TUZYX8I/AAAAAAAAAHE/kDs6BJ426xI/s320/termografia-interruptor-aire-mal-cerrado.jpg" alt="visión con cámara termográfica" id="BLOGGER_PHOTO_ID_5116436954259939266" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;br /&gt;&lt;p align="center"&gt;Interruptor de aire cerrado incorrectamente&lt;/p&gt;&lt;br /&gt;&lt;p align="center"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/camaras-termograficas/" title="Enlace externo a sección de Termografía de Amperis.com"&gt;&lt;img style="cursor: pointer;" src="http://1.bp.blogspot.com/_liWG2cxeH1g/RwE8vUZYX9I/AAAAAAAAAHM/FVn2-_WoJ1w/s320/termografia-desequilibrio-carga.jpg" alt="Termografía" id="BLOGGER_PHOTO_ID_5116437435296276434" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;br /&gt;&lt;p align="center"&gt;Desequilibrio de la carga&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;p align="center"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/camaras-termograficas/" title="Enlace externo a sección de Termografía de Amperis.com"&gt;&lt;img style="cursor: pointer;" src="http://1.bp.blogspot.com/_liWG2cxeH1g/RwE9OUZYX-I/AAAAAAAAAHU/qVIiq_L9F1s/s320/termografia-cables-sueltos-fundidos.gif" alt="cámaras termográficas detectando malas conexiones" id="BLOGGER_PHOTO_ID_5116437967872221154" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;br /&gt;&lt;p align="center"&gt;Deterioro en la conexión&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;h4&gt;Qué puede ser detectado:&lt;/h4&gt;&lt;ul type="disc"&gt;&lt;li&gt;Las conexiones deterioradas&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Sobrecargas&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Cargas desequilibradas.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Circuitos abiertos&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Calor inductivo&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Armónicos&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Equipo defectuoso&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;h4&gt;Ventajas:&lt;/h4&gt;&lt;ul type="disc"&gt;&lt;li&gt;Localizar los problemas rápidamente, sin necesidad de interrupción&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Reducir el coste de las interrupciones graves, no programadas de la energía&lt;/li&gt;&lt;br /&gt;&lt;li&gt;reducir al mínimo el tiempo del mantenimiento preventivo y maximizar la eficacia de localización de averías&lt;/li&gt;&lt;br /&gt;&lt;li&gt;prevenir el error prematuramente y ampliar la vida del equipo&lt;/li&gt;&lt;br /&gt;&lt;li&gt;identificar el equipo potencialmente peligroso &lt;/li&gt;&lt;br /&gt;&lt;li&gt;reducir las primas de seguro y los pagos deducibles&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-weight: bold;"&gt;Sepa más sobre termografía en la sección de &lt;a href="http://www.amperis.com/productos/camaras-termograficas/" title="enlace externo a Amperis.com"&gt;cámaras termográficas&lt;/a&gt; de Amperis.com&lt;/span&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6747872199407285579?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6747872199407285579/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6747872199407285579' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6747872199407285579'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6747872199407285579'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/10/termografia-ventajas.html' title='Termografia: Ventajas'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_liWG2cxeH1g/RwE8TUZYX8I/AAAAAAAAAHE/kDs6BJ426xI/s72-c/termografia-interruptor-aire-mal-cerrado.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-7445226518005797009</id><published>2007-09-27T17:01:00.000-07:00</published><updated>2007-09-27T18:20:02.168-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='megger'/><category scheme='http://www.blogger.com/atom/ns#' term='ohmímetros'/><category scheme='http://www.blogger.com/atom/ns#' term='megóhmetros'/><category scheme='http://www.blogger.com/atom/ns#' term='generadores'/><title type='text'>Megohmetro</title><content type='html'>Existen variadas herramientas para los electricistas y para quienes proporcionan servicio a los generadores eléctricos. Aparte de los utensilios básicos como son: pinzas, desarmadores, llaves de diferente tamaño, etc., que pueden ser catalogados como herramientas de tipo mecánico, existen también diferentes aparatos que se utilizan para medir tensiones eléctricas en los devanados, niveles de aislamiento, corto circuitos en bobinas, potencia del alternador, voltaje, etc.&lt;br /&gt;Entre los instrumentos más importantes se tienen los siguientes.&lt;br /&gt;&lt;br /&gt;Utilizado a nivel industrial, el &lt;a title="Meghómetros en Amperis.com" href="http://www.amperis.com/productos/megohmetros/"&gt;Megóhmetro&lt;/a&gt; o &lt;em&gt;megger&lt;/em&gt; es un aparato que permite establecer la resistencia de aislamiento existente en un conductor o sistema de tierras. Funciona en base a la generación temporal de una sobrecorriente eléctrica la cual se aplica al sistema hasta que se rompe su aislamiento, al establecerse un arco eléctrico…&lt;br /&gt;&lt;br /&gt;El Megger es un instrumento del tipo de los &lt;a title="Ohmímetros en Amperis.com" href="http://www.amperis.com/productos/ohmimetros/"&gt;Ohmímetros&lt;/a&gt;, en el que el valor de la resistencia que se mide se registra directamente sobre una escala y esta indicación es independiente de la tensión. Consta de dos partes principales: &lt;ul&gt;&lt;li&gt;Un generador de corriente continua de tipo magnetoeléctrico, movido generalmente a mano o electrónicamente (Megger digital), que suministra la corriente para llevar a cabo la medición&lt;/li&gt; &lt;li&gt;Y el mecanismo del instrumento por medio del cual se mide el valor de la resistencia que se busca.&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;span class="inline left"&gt;&lt;a title="Megóhmetro MOH-5 Amperis" href="http://www.amperis.com/productos/megohmetros/"&gt;&lt;img style="width: 110px; height: 224px;" src="http://www.amperis.com/images/megohmetros/megohmetro-moh-5.jpg" alt="megóhmetros, megohmetro" /&gt;&lt;/a&gt;&lt;span class="caption"&gt;&lt;strong&gt;&lt;a href="http://www.amperis.com/productos/megohmetros/"&gt;Megóhmetro&lt;/a&gt;&lt;br /&gt;digital MOH-5&lt;br /&gt;Amperis&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;p&gt;El Megóhmetro tiene dos imanes permanentes rectos, colocados paralelamente entre sí. El inducido del generador, junto con sus piezas polares de hierro, está montado entre dos de los polos de los imanes paralelos, y las piezas polares y el núcleo móvil del instrumento se sitúan entre los otros dos polos de los imanes.&lt;/p&gt;&lt;br /&gt;El inducido del generador se acciona a mano, regularmente, aumentándose su velocidad por medio de engranajes. Para los ensayos corrientes de aislamiento, la tensión que más se usa es la de 500 voltios, pero con el fin de poder practicar ensayos simultáneos a alta tensión, pueden utilizarse tensiones hasta 2500 voltios.&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-7445226518005797009?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/7445226518005797009/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=7445226518005797009' title='1 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/7445226518005797009'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/7445226518005797009'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/09/megohmetro.html' title='Megohmetro'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-3418776827995250903</id><published>2007-08-16T07:00:00.000-07:00</published><updated>2007-08-16T07:11:19.249-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='redes'/><category scheme='http://www.blogger.com/atom/ns#' term='paneles'/><category scheme='http://www.blogger.com/atom/ns#' term='medidores'/><category scheme='http://www.blogger.com/atom/ns#' term='electricas'/><category scheme='http://www.blogger.com/atom/ns#' term='v-switch'/><category scheme='http://www.blogger.com/atom/ns#' term='analizadores'/><title type='text'>Analizador Redes - SHARK-100</title><content type='html'>&lt;h2&gt;Analizador de redes multifuncional SHARK 100.&lt;br /&gt;Características generales&lt;/h2&gt; &lt;img src="http://www.amperis.com/images/analizadores-redes-electricas/analizador-redes-electricas-shark-100-g.jpg" alt="analizador de redes multifuncional shark 100" class="image-product" longdesc="medidor multifuncional de potencia y energía" height="300" width="276" /&gt; &lt;ul&gt;&lt;li&gt;Medidor con Certificado de Facturación Clase 0.2% para medición de demanda y energía.&lt;/li&gt;&lt;li&gt;Cumple con norma ANSI C12.20 (0.2%) e IEC 687 (0.2%) de clase de precisión.&lt;/li&gt;&lt;li&gt;Mediciones multifuncionales que incluyen Voltaje, Corriente, Potencia, Frecuencia, Energía, etc.&lt;/li&gt;&lt;li&gt;Pulso KYZ Opcional.&lt;/li&gt;&lt;li&gt;Mediciones de calidad de potencia (%THD y Limites con Alarma).&lt;/li&gt;&lt;li&gt;Tecnología V-Switch® - Actualizable en campo sin remover el equipo instalado.&lt;/li&gt;&lt;li&gt;Pantalla de LED rojo brillante de 3 Lineas de .56".&lt;/li&gt;&lt;li&gt;Barra de % de carga para percepción de Medidor Análogo.&lt;/li&gt;&lt;li&gt;Protocolos RS485 Modbus y DNP 3.0 - 57.6K Baud..&lt;/li&gt;&lt;li&gt;Puerto IrDA para lectura remota con PDA.&lt;/li&gt;&lt;li&gt;Ultra compacto, fácil de instalar.&lt;/li&gt;&lt;li&gt;Se acopla en ranuras ANSI y DIN.&lt;/li&gt;&lt;li&gt;Disponible en versión de "Sólo Transductor".&lt;/li&gt;&lt;/ul&gt; &lt;p class="text-right"&gt;&lt;strong&gt;Tecnología líder en la Industria&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;• Prestaciones de medidor de facturación&lt;br /&gt;• Bajo costo&lt;br /&gt;• &lt;strong&gt;!El Medidor más fácil de usar del mercado!&lt;/strong&gt;&lt;/p&gt; &lt;h2&gt;Aplicaciones&lt;/h2&gt; &lt;ul&gt;&lt;li&gt;Medición en empresas eléctricas&lt;/li&gt;&lt;li&gt;Medición comercial&lt;/li&gt;&lt;li&gt;Sub estaciones&lt;/li&gt;&lt;li&gt;Medición industrial&lt;/li&gt;&lt;li&gt;Generación&lt;/li&gt;&lt;li&gt;Medición en campus&lt;/li&gt;&lt;li&gt;Sub medición&lt;/li&gt;&lt;li&gt;Reemplazo de medición análoga&lt;/li&gt;&lt;/ul&gt;  &lt;h2&gt;Introducción&lt;/h2&gt;  &lt;p&gt;Amperis introduce uno de los medidores grado de facturación tipo panel de mayores prestaciones en la Industria. Basado en una nueva plataforma, este medidor de bajo costo supera significativamente en funciones a otros equipos mucho más costosos.&lt;br /&gt;Esta unidad es perfecta para nuevas aplicaciones de medición y para un reemplazo directo y simple de los medidores analógicos existentes.&lt;br /&gt;El Shark es excelente para la medición de energía de alta precisión   excediendo las normas de medición de Energía ANSI C12.20 (0.2%) e IEC 687 (0.2%).&lt;br /&gt;&lt;br /&gt;La unidad emplea tecnología de alta velocidad tipo DSP con conversión A/D de gran resolución para proveer precisión certificada de facturación, para Empresas Eléctricas, Medición de Sub Estaciones, Medición Principal y Sub Medición así como aplicaciones de Medición Crítica.&lt;/p&gt;     &lt;h2&gt;Tecnología V-Switch, paquetes de actualización de mediciones&lt;/h2&gt;      &lt;p&gt; El Shark 100 está equipado con la tecnología Exclusiva de EIG V-Switch®. V-Switch® es un switch virtual basado en firmware que permite habilitar características en el medidor a través de la comunicación, incluso después de la instalación. Empleando los V-Switches, usted puede ordenar lo que requiera ahora, y actualizar en campo las demás funciones conforme las necesite. Esto permite optimizar su inversión en Medición. Inicie con un simple medidor indicador y actualícelo a un medidor de energía clase facturación con funciones completas y capacidad de medición avanzada. Versiones avanzadas del SHARK100 (V3 y V4) también incluyen protocolo de comunicación DNP 3.0.&lt;/p&gt; &lt;strong&gt;V-Switches Disponibles:&lt;/strong&gt; &lt;ul&gt;&lt;li&gt;V-Switch  1 – Voltios y Amperios – Default&lt;/li&gt;&lt;li&gt;V-Switch 2 – Voltios, Amperios, kW, kVAR, FP, kVA, Frec.&lt;/li&gt;&lt;li&gt;V-Switch 3 – Voltios, Amperios, kW, kVAR, FP, kVA, Frec. kWh, kVAh, kVARh y DNP 3.0&lt;/li&gt;&lt;li&gt;V-Switch 4 – Voltios, Amperios, kW, kVAR, FP, kVA, Frec. kWh, kVAh, kVARh, Monitoreo de %THD, Limites y Alarmas y DNP 3.0&lt;/li&gt;&lt;/ul&gt;  &lt;h2&gt;Fácil de usar e instalar&lt;/h2&gt; &lt;p&gt;Los ingenieros de EIG diseñaron este medidor para hacerlo lo más sencillo para usar e instalar. Desde la interfaz de usuario hasta su construcción mecánica, muchas horas fueron empleadas para hacer del Shark un equipo intuitivo y consistente para que un instalador con experiencia mínima y capacitación básica pudiese usar el equipo.&lt;br /&gt;&lt;br /&gt;El Shark puede ser programado empleando una PDA, una PC o a través de la sencilla interfaz de teclado frontal. Adicionalmente, empleando la PC o la PDA, el técnico o el Ingeniero pueden visualizar el diagrama de fasores como vectores, asegurándose que las polaridades de los CTs voltajes son las correctas. Todas las entradas estan marcadas con código de colores y etiquetadas de forma simple y fácil de identificar para evitar errores de instalación. Esto es muy útil en aplicaciones de OEM en las cuales el tiempo de instalación afecta al costo del producto.&lt;/p&gt; &lt;ul&gt;&lt;li&gt;Fácil programación por pantalla frontal.&lt;/li&gt;&lt;li&gt;Configuración desde PC.&lt;/li&gt;&lt;li&gt;Configuración desde PDA empleando el puerto IrDA.&lt;/li&gt;&lt;li&gt;Diagrama de Fasores con estado de conexión.&lt;/li&gt;&lt;li&gt;Característica de "Auto Scroll".&lt;/li&gt;&lt;li&gt;Barra de % de Carga estilo análogo.&lt;/li&gt;&lt;li&gt;Poca profundidad exigida al Panel donde se instalará.&lt;/li&gt;&lt;li&gt;Terminales de Voltajes y comunicación de rápida instalación.&lt;/li&gt;&lt;li&gt;Hilos de entradas de corriente "Atraviesan" el medidor.&lt;/li&gt;&lt;li&gt;Entradas de Voltajes y Corrientes coordinadas por color.&lt;/li&gt;&lt;/ul&gt; &lt;table class="gb-center" width="100%"&gt; &lt;tbody&gt;&lt;tr&gt; &lt;td&gt; &lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/analizadores-redes/shark-100/"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://1.bp.blogspot.com/_liWG2cxeH1g/RsRaVYdp9XI/AAAAAAAAAAs/6Se9EBOfZKE/s400/shark-100-detalles.jpg" alt="analizador de redes eléctricas shark 100" id="BLOGGER_PHOTO_ID_5099300001480832370" border="0" /&gt;&lt;/a&gt; &lt;/td&gt; &lt;/tr&gt; &lt;/tbody&gt;&lt;/table&gt;   &lt;a title="Catálogo PDF del Analizador de redes SHARK 100" href="http://www.amperis.com/productos/analizadores-redes/catalogos-pdf/analizador-redes-Shark100.pdf"&gt;&lt;img src="http://www.amperis.com/images/catalogo-pdf.png" alt="analizador redes multifuncional shark 100" /&gt; Vea todas las características en el catálogo .pdf [1.03 Mb.]&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-3418776827995250903?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/3418776827995250903/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=3418776827995250903' title='1 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/3418776827995250903'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/3418776827995250903'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/08/analizador-redes-shark-100.html' title='Analizador Redes - SHARK-100'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_liWG2cxeH1g/RsRaVYdp9XI/AAAAAAAAAAs/6Se9EBOfZKE/s72-c/shark-100-detalles.jpg' height='72' width='72'/><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-8691187431808344122</id><published>2007-08-16T06:56:00.000-07:00</published><updated>2007-08-16T06:58:06.226-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='redes'/><category scheme='http://www.blogger.com/atom/ns#' term='electricas'/><category scheme='http://www.blogger.com/atom/ns#' term='alta tecnología'/><category scheme='http://www.blogger.com/atom/ns#' term='analizadores'/><title type='text'>Analizadores de redes electricas avanzados</title><content type='html'>&lt;table class="gb" width="100%"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;&lt;a href="http://www.amperis.com/productos/analizadores-redes/shark-100/"&gt;&lt;img src="http://www.amperis.com/images/analizadores-redes-electricas/analizador-redes-electricas-shark-100-p.jpg" alt="analizador de redes shark 100" longdesc="producto líder en industria como analizador de redes y contador de energía" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt; El Shark 100 es un producto líder en la industria como analizador de redes y contador de energía. Certificado para la clase de precisión 0,2 es el equipo más fácil de utilizar e instalar del mercado.&lt;br /&gt;     &lt;br /&gt;      &lt;a title="Analizador de Redes SHARK 100" href="http://www.amperis.com/productos/analizadores-redes/shark-100/"&gt;[leer más en amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;&lt;a title="Analizador de Redes 1272" href="http://www.amperis.com/productos/analizadores-redes/nexus-1272/"&gt;&lt;img src="http://www.amperis.com/images/analizadores-redes-electricas/analizador-redes-electricas-nexus-1272-p.jpg" alt="analizador de redes nexus 1272" longdesc="contador energía precisión 0,06% kWh" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt;El Nexus 1272 es un contador de energía con una precisión de 0,06% en kWh, tiene una vida útil estimada de 20 años y es un avanzado registrador de calidad de energía. Mantiene la precisión hasta los 70ºC (el equipo se autocalibra cada variación de temperatura de 5ºC) y es el equipo con mejores posibilidades de comunicación del mercado: MODEM, ethernet, 2 puertos RS 485 y plasmación automática de datos en una página web fácilmente parametrizable. &lt;a title="Analizador de Redes 1272" href="http://www.amperis.com/productos/analizadores-redes/nexus-1272/"&gt;[Leer más en amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;&lt;a title="Analizador de Redes SHARK 100S" href="http://www.amperis.com/productos/analizadores-redes/shark-100s/"&gt;&lt;img src="http://www.amperis.com/images/analizadores-redes-electricas/analizador-redes-electricas-shark-100s-p.jpg" alt="analizador de redes shark 100s" longdesc="analizador de redes contador con posibilidad de comunicación ethernet wifi" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt;Shark 100 S, es un analizador de redes con función contador con posibilidad de comunicación por ethernet vía wifi, lo que lo hace ideal como contador de medidas parciales en edificios comerciales, institucionales, industriales y centros comerciales.&lt;br /&gt;     &lt;br /&gt;      &lt;a title="Analizador de Redes SHARK 100S" href="http://www.amperis.com/productos/analizadores-redes/shark-100s/"&gt;[Leer más en amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;&lt;a title="Analizador de Redes DPM-5" href="http://www.amperis.com/productos/analizadores-redes/dpm-5/"&gt;&lt;img src="http://www.amperis.com/images/analizadores-redes-electricas/analizador-redes-electricas-dpm-5-p.jpg" alt="analizador de redes DPM-5" longdesc="mide multitud parámetros red trifásica comunicación RS-485" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt;DPM-5 equipo de una gran relación calidad precio, mide multitud de parámetros de una red trifásica y tiene comunicación RS-485 con protocolo MODBUS RTU.&lt;br /&gt;      &lt;a title="Analizador de Redes DPM-5" href="http://www.amperis.com/productos/analizadores-redes/dpm-5/"&gt;[Leer más en amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt; &lt;/tbody&gt;&lt;/table&gt;  &lt;p&gt;Amperis  dispone de una amplia gama de &lt;a title="Analizador de Redes" href="http://www.amperis.com/productos/analizadores-redes/"&gt;analizadores de redes&lt;/a&gt;, destacan los fabricados  por la empresa &lt;em&gt;Electro Industries&lt;/em&gt;, &lt;strong&gt;los más avanzados del mercado en precisión y  conectividad&lt;/strong&gt;.&lt;/p&gt; &lt;p&gt;Los analizadores de redes de la gama Nexus disponen de la tecnología &lt;em&gt;AccuMesure&lt;/em&gt;, que garantiza una precisión estable hasta los 70ºC, a lo que se une (para las gamas Nexus y Shark), &lt;strong&gt;una garantía de 4 años&lt;/strong&gt;, &lt;strong&gt;algo todavía sin parangón en el sector  de la medida eléctrica&lt;/strong&gt;.&lt;/p&gt; &lt;p&gt;El Shark 100 es un analizador de redes eléctricas con clase de precisión de contador, tiene variantes, el Shark 100T: una versión sólo transductor o el Shark 100 S, con comunicación ethernet vía wifi (pero también con puerto RJ 45) lo que lo convierte en un &lt;strong&gt;medidor indicado para edificios comerciales, institucionales, industriales y centros comerciales&lt;/strong&gt;.&lt;/p&gt; &lt;p&gt;El Shark 100 destaca también por su fácil conexionado. Si no encuentra lo que  busca no dude en &lt;a title="Contacte ahora con su proveedor de equipos eléctricos" href="http://www.amperis.com/contacto/"&gt;contactarnos&lt;/a&gt;,  pues es más que probable que sepamos darle una solución.&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-8691187431808344122?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/8691187431808344122/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=8691187431808344122' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8691187431808344122'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/8691187431808344122'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/08/analizadores-de-redes-electricas.html' title='Analizadores de redes electricas avanzados'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6927564429408968628</id><published>2007-08-01T04:26:00.000-07:00</published><updated>2007-07-31T05:01:47.399-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='infrarrojos'/><category scheme='http://www.blogger.com/atom/ns#' term='cámaras térmicas'/><category scheme='http://www.blogger.com/atom/ns#' term='termografía'/><title type='text'>Termografia Infrarroja</title><content type='html'>&lt;p&gt;La Termografía es la rama de la Teledetección que se ocupa de la medición de la temperatura radiada por los fenómenos de la superficie de la Tierra desde una cierta distancia. Una Termografía Infrarroja es la técnica de producir una imagen visible de luz infrarroja invisible (para nuestros ojos) emitida por objetos de acuerdo a su condición térmica. Una cámara Termográfica produce una imagen en vivo. (Visualizada como fotografía de la temperatura de la radiación) Las cámaras miden la temperatura de cualquier objeto o superficie de la imagen y producen una imagen con colores que interpretan el diseño térmico con facilidad. Una imagen producida por una cámara infrarroja es llamada: Termografía o Termograma. &lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;h4&gt;FUNDAMENTOS DE LA TERMOGRAFÍA POR INFRARROJOS&lt;/h4&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;La Termografía Infrarroja es una técnica que permite, a distancia y sin ningún contacto, medir y visualizar temperaturas de superficie con precisión. La Física permite convertir las mediciones de la radiación infrarroja en medición de temperatura, esto se logra midiendo la radiación emitida en la porción infrarroja del espectro electromagnético desde la superficie del objeto, convirtiendo estas mediciones en señales eléctricas.&lt;br /&gt;Los ojos humanos no son sensibles a la radiación infrarroja emitida por un objeto, pero las cámaras termográficas, o de termovisión, son capaces de medir la energía con sensores infrarrojos, capacitados para "ver" en estas longitudes de onda. Esto nos permite medir la energía radiante emitida por objetos y, por consiguiente, determinar la temperatura de la superficie a distancia, en tiempo real y sin contacto.&lt;br /&gt;&lt;br /&gt;La radiación infrarroja es la señal de entrada que la cámara termográfica necesita para generar una imagen de un espectro de colores, en el que cada uno de los colores, según una escala determinada, significa una temperatura distinta, de manera que la temperatura medida más elevada aparece en color blanco. &lt;/p&gt;&lt;br /&gt;&lt;h4&gt;DESCUBRIMIENTO DE LOS RAYOS INFRARROJOS&lt;/h4&gt;&lt;br /&gt;&lt;p&gt;El descubridor de los rayos infrarrojos fue Sir Frederick William Herschel nacido en Hannover, Alemania 1738.&lt;br /&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;Fue muy conocido tanto como músico y como astrónomo. En el año 1757 emigró hacia Inglaterra donde con su hija Carolina construyeron un Telescopio. Su más famoso descubrimiento fue el del planeta Urano en el año 1781. En el año de 1800, Sir William Herschel hizo otro descubrimiento muy importante.&lt;/p&gt;  &lt;p&gt;Se interesó en verificar cuanto calor pasaba por filtros de diferentes colores al ser observados al sol.&lt;/p&gt;  &lt;p&gt;Se dio cuenta que esos filtros de diferentes colores dejaban pasar diferente nivel de calor. Continuando con ese experimento, Herschel hizo pasar luz del sol por un prisma de vidrio y con esto se formó un espectro (el "arco iris" que se forma cuando se divide a la luz en sus colores).&lt;/p&gt;  &lt;p&gt;Haciendo controles de temperatura en los distintos colores de ese espectro verificó que más allá de rojo fuera de las radiaciones visibles la temperatura era más elevada. Encontró que esta radiación invisible por encima del rojo se comporta de la misma manera desde el punto de vista de la reflexión, refracción, absorción y transmisión que la luz visible. Era la primera vez que alguien demostraba que había otra forma de iluminación o radiación que era invisible al ojo humano. Esta radiación inicialmente la denominó Rayos caloríficos y luego Infrarrojos (infra: quiere decir abajo) Es decir por debajo del nivel de energía del rojo.&lt;/p&gt;  &lt;p&gt;El año 2000 marca el 200 aniversario del descubrimiento de William Herschel del infrarrojo y este aniversario encuentra a la tecnología Infrarroja en plena expansión en todas sus aplicaciones. La Astronomía, la medicina, la seguridad pública, en el rescate, en la electrónica, en la meteorología, la ingeniería de procesos, el mantenimiento industrial, el análisis de la vegetación, el estudio de las temperaturas de los océanos, por mencionar algunas. No solo se encuentra en plena expansión, sino que también se perfila como una tecnología de uso masivo en el medio plazo.&lt;/p&gt;  &lt;p&gt;Ampliando términos, transferencia de calor es energía en tránsito debido a diferencias de temperatura. El calor es una cosa intangible. Nosotros no podemos medir en forma directa el calor. Solamente podemos medir los efectos del calor, a saber: cambios de la temperatura.&lt;/p&gt;  &lt;p&gt;La transferencia de calor puede ser por conducción, convección o radiación o por sus combinaciones. La velocidad (la diferencia genera contraste) de calentamiento o enfriamiento depende de las propiedades térmicas, estado físico, tamaño y naturaleza del producto, así como el mecanismo de transferencia. La termografía infrarroja logra obtener, a partir de esa energía radiada en el rango infrarrojo (0,7 a 15 micras), la temperatura del cuerpo emisor.&lt;/p&gt;  &lt;p&gt;La Termografía Infrarroja o la utilización de cámaras térmicas obligan al profesional a evaluar las tres formas de transferencia de calor. La Termografía no es simplemente la generación de una imagen con una determinada cámara térmica / infrarroja.&lt;/p&gt;  &lt;p&gt;La técnica de generación de la imagen y la evaluación de la misma debe ser considerada como un ensayo térmico.&lt;/p&gt;  &lt;p&gt;A pesar de la comodidad y fiabilidad de las cámaras termográficas, su uso no está demasiado extendido en nuestro país.&lt;!-- “Las únicas que la utilizan son las consultoras, para hacer inspecciones de edificios, o firmas privadas como FENOSA, que las instalan en un helicóptero para detectar fallos en sus líneas de tensión”, apunta el físico vigués Ramiro Álvarez Clavero del servicio de teledetección del Vicerrectorado de Investigación de la Universidad de Vigo. &lt;/p&gt;  &lt;p&gt;La propia universidad alquila la suya, valorada en más de 90.000 euros, a las empresas que la soliciten tras recibir un curso de formación a cargo del responsable del Servicio de Teledetección: “Hay cámaras especificas mucho más baratas que la nuestra y que con un coste de unos 60 euros pueden ser utilizadas por albañiles, electricistas o arquitectos para detectar fugas de la calefacción y humedades en el interior de las viviendas o en los tejados, en Estados Unidos ya trabajan así”.  --&gt;&lt;/p&gt;  &lt;p&gt; Las &lt;a href="http://www.amperis.com/productos/camaras-termograficas/"&gt;cámaras termográficas&lt;/a&gt; han sido desarrolladas con tecnología Uncooled Focal Plane Array detector (UFPA) consistente de una matriz de dos dimensiones (320x240) formada por unos detectores conocidos como microbolómetros. &lt;/p&gt;  &lt;p&gt; Los infrarrojos inciden en el detector como onda electromagnética, la temperatura del detector aumenta por la absorción de la energía de la radiación, la resistencia del detector cambia, y finalmente el cambio de resistencia crea la señal eléctrica.&lt;/p&gt;  &lt;p&gt;Para la medición de la temperatura se dispone de una cámara termográfica desarrollada para trabajos de detección y prevención que es capaz de realizar medidas de temperatura tanto en el interior como en el exterior.&lt;/p&gt;  &lt;p&gt; Las características principales de la cámara son su pequeño tamaño, ligereza y alta calidad de imagen.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;¿QUE USOS PUEDE TENER UNA TERMOGRAFÍA?&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;Las termografías pueden ser aplicadas en cualquier situación donde un problema o condición pueda ser visualizado por medio de una diferencia de temperatura. Una termografía puede tener aplicación en cualquier área siempre y cuando esta tenga que ver con variación de temperatura. &lt;/p&gt;  &lt;p&gt;Detecta problemas rápidamente sin interrumpir el funcionamiento del equipo.&lt;/p&gt;  &lt;p&gt;Minimiza el mantenimiento preventivo y el tiempo perdido en localizar los problemas.&lt;/p&gt;&lt;br /&gt;&lt;p&gt;Puede ser utilizada por compañías de seguros para cerciorarse que el equipo o las instalaciones se encuentran en estado óptimo.&lt;br /&gt;Previene incendios o accidentes.&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;h4&gt;CAMPOS DE APLICACIÓN&lt;/h4&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;DESARROLLO Y ESTRUCTURA DE EDIFICIOS:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Inspección de pérdida de energía térmica para Edificios (plantas, maquiladoras, hoteles, edificios gubernamentales, etc.)&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Evaluación de la humedad para Edificios (plantas, maquiladoras, hoteles, edificios gubernamentales)&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Inspecciones de integridad del concreto&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Inspecciones en pisos sobrecalentados, localización de fugas y distribución de temperatura.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Localiza aislamiento dañada o faltante&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Identifica perdidas y fugas de energía&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Localiza cables, conductores o tuberías sobrecalentados&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;SISTEMA DE TECHADO:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Detección de Goteras para edificios y naves industriales.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Identifica partes de techos dañadas por el agua rápida y eficientemente.&lt;/li&gt; &lt;li&gt;Documenta problemas antes de que las garantías u obligaciones expiren&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;SISTEMAS MECANICOS:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Evaluación de equipos de aire acondicionado y calefacción&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Pérdidas de frío en cuartos fríos.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Detección de fugas en el aislamiento en equipos de refrigeración&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;APLICACIONES AMBIENTALES:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;  &lt;li&gt;Localización de áreas de acumulación de desechos antiguos&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Localización de tanques bajo tierra en zonas industriales&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Localiza daños de arquitecturas y/o esculturas&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;APLICACIONES AEREAS:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Inspecciones aéreas eléctricas de alto voltaje para líneas de transmisión&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Búsqueda de sobrevivientes&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;APLICACIONES VARIAS:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Localización de incendios de baja intensidad en en bosques densos.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Localización de personas perdidas&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Localización de personas atrapadas en incendios de edificios así como poder caminar a través del humo. &lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;BIOLOGÍA Y MEDICINA&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt; &lt;li&gt;Electricidad y electrónica: Fallos en líneas de alta, media y baja tensión&lt;/li&gt; &lt;li&gt;Caracterización de materiales&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;RADIOMETRÍA:&lt;/strong&gt;&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Estudios de imágenes térmicas procedentes de objetos enterrados.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Huellas térmicas de minas enterradas, etc.&lt;/li&gt; &lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;ENSAYOS NO DESTRUCTIVOS&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;MECÁNICA DEL ESTADO SÓLIDO&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;MECÁNICA DE FLUIDOS:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Transferencia de calor en fluidos&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Capacidad de radiadores&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;APLICACIONES INDUSTRIALES:&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Trabajos de conservación y restauración.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Mantenimiento eléctrico&lt;/li&gt; &lt;li&gt;Control de calidad &lt;/li&gt;&lt;br /&gt;&lt;li&gt;Inspección de edificios y obras de arte.&lt;/li&gt;  &lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6927564429408968628?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6927564429408968628/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6927564429408968628' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6927564429408968628'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6927564429408968628'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/08/termografia-infrarroja.html' title='Termografia Infrarroja'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-4157238738151993180</id><published>2007-07-19T16:07:00.000-07:00</published><updated>2007-07-19T16:21:28.552-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='redes'/><category scheme='http://www.blogger.com/atom/ns#' term='electricas'/><category scheme='http://www.blogger.com/atom/ns#' term='analizadores'/><title type='text'>Analizadores de redes</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/analizadores-redes/"&gt;&lt;img style="margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 200px;" src="http://www.amperis.com/images/analizadores-redes-electricas/analizador-redes-electricas-dpm-5.jpg" alt="analizador redes" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;h4&gt;Analizando &lt;a title="Analizadores de redes eléctricas" href="http://www.amperis.com/productos/analizadores-redes/"&gt;analizadores de redes&lt;/a&gt; eléctricas&lt;/h4&gt;&lt;br /&gt;&lt;h4&gt;Analizador de redes eléctricas DPM-5&lt;/h4&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Analizador de redes que &lt;strong&gt;muestra de forma centralizada los parámetros fundamentales de una red eléctrica.&lt;/strong&gt;&lt;/li&gt;&lt;li&gt;El analizador de redes eléctricas DPM-5 es el equipo &lt;strong&gt;ideal para paneles de control de industrias, centrales de generación, motores, control de energía de edificios&lt;/strong&gt;, etc.&lt;/li&gt;&lt;li&gt;Apropiado para &lt;strong&gt;sustituir de una forma económica instrumentos de panel tradicionales&lt;/strong&gt;&lt;/li&gt;&lt;li&gt;&lt;strong&gt;Salidas analógicas y comunicación MODBUS RS-485&lt;/strong&gt;&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;h4&gt;&lt;a title="Analizador de redes eléctricas DPM-5" href="http://www.amperis.com/productos/analizadores-redes/"&gt;Analizador de redes&lt;/a&gt; eléctricas DPM-5&lt;/h4&gt;&lt;h4&gt;General&lt;/h4&gt; &lt;ol&gt;&lt;li&gt;Teclado de 4 teclas de membrana que permite visualizar todas las magnitudes medidas y realizar ajustes sin necesidad de programación.&lt;/li&gt;&lt;li&gt;Posibilidad de conectarse a redes monofásicas o trifásicas de 3 ó 4 hilos.&lt;/li&gt;&lt;li&gt;Mediante la conexión RS-485 pueden conectarse &lt;strong&gt;hasta 32 analizadores de redes eléctricas &lt;/strong&gt;DPM-5 por cada línea&lt;/li&gt;&lt;li&gt;Medidas en verdadero valor eficaz&lt;/li&gt;&lt;/ol&gt;&lt;br /&gt;&lt;h4&gt;Características&lt;/h4&gt;  &lt;table width="100%"&gt;&lt;tbody&gt;&lt;tr&gt;    &lt;td&gt;Magnitudes medidas:&lt;/td&gt;    &lt;td&gt;Tensión, corriente, potencia activa, potencia reactiva, potencia aparente, frecuencia, factor de potencia, energía activa y reactiva&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Tipos de red:&lt;/td&gt;    &lt;td&gt;monofásica, trifásica de 3 ó 4 hilos (con y sin neutro accesible)&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Alimentación:&lt;/td&gt;    &lt;td&gt;80V~270V AC ó DC&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Protección frontal: &lt;/td&gt;    &lt;td&gt;IP52&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Peso:&lt;/td&gt;    &lt;td&gt;0,45 kg&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Dimensiones:&lt;/td&gt;    &lt;td&gt;96×96×83mm (alto×ancho×fondo); perforación en panel: 91×91 mm&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Temperatura:&lt;/td&gt;    &lt;td&gt;almacenaje/funcionamiento; humedad: -20ºC~+75ºC/- 10ºC~+55ºC;&amp;lt;90%&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Normas:&lt;/td&gt;    &lt;td&gt;IEC EN50081-2, IEC EN50082-1, IEC EN61010-1&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Comunicación:&lt;/td&gt;    &lt;td&gt;RS-485/MODBUS-RTU&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Velocidad/dirección: &lt;/td&gt;    &lt;td&gt;4800~38400 bps/1~247&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Aislamiento:&lt;/td&gt;    &lt;td&gt;&amp;gt;5 MΩ; 2 kV / 50 Hz&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Ensayo de tensión: &lt;/td&gt;    &lt;td&gt;1 min 20 kV / 50 Hz&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Salida analógica:&lt;/td&gt;    &lt;td&gt;2; NO (normalmente abierta); duración del pulso: 80 ms; tipo: optoacoplada&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br /&gt;&lt;br /&gt;&lt;em&gt;leyenda&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;table class="image-product" width="100%"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Magnitudes&lt;/td&gt;    &lt;td&gt;medidas&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;V&lt;/td&gt;    &lt;td&gt;Tensión&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;I&lt;/td&gt;    &lt;td&gt;Corriente&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;W&lt;/td&gt;    &lt;td&gt;Potencia activa&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;VAr&lt;/td&gt;    &lt;td&gt;Potencia reactiva&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;VA&lt;/td&gt;    &lt;td&gt;Potencia aparente&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;cos f&lt;/td&gt;    &lt;td&gt;Factor de potencia (Pf)&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;Hz&lt;/td&gt;    &lt;td&gt;Frecuencia&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;kWh&lt;/td&gt;    &lt;td&gt;Contador de energía activa&lt;/td&gt;  &lt;/tr&gt;  &lt;tr&gt;    &lt;td&gt;VArh&lt;/td&gt;    &lt;td&gt;Contador de energía reactiva&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-4157238738151993180?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/4157238738151993180/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=4157238738151993180' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4157238738151993180'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4157238738151993180'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/analizadores-de-redes.html' title='Analizadores de redes'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-1889788897531345143</id><published>2007-07-12T04:56:00.000-07:00</published><updated>2007-07-12T05:05:24.862-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='resistencia'/><category scheme='http://www.blogger.com/atom/ns#' term='ohmímetros'/><category scheme='http://www.blogger.com/atom/ns#' term='aislamiento'/><title type='text'>Ohmimetro</title><content type='html'>&lt;h4&gt;El Ohmimetro:&lt;/h4&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/images/ohmetros/ohmetro-ome-10.jpg"&gt;&lt;img style="margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 200px;" src="http://www.amperis.com/images/ohmetros/ohmetro-ome-10.jpg" alt="Ohmímetro" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Es un arreglo de los circuitos del Voltímetro y del Amperímetro, pero con una batería y una resistencia. Dicha resistencia es la que ajusta en cero el instrumento en la escala de los Ohmios cuando se cortocircuitan los terminales. En este caso, el voltímetro marca la caída de voltaje de la batería y si ajustamos la resistencia variable, obtendremos el cero en la escala. Generalmente, estos instrumentos se venden en forma de Multímetro el cual es la combinación del amperímetro, el voltímetro y el Ohmimetro juntos. Los que se venden solos son llamados &lt;a href="http://www.amperis.com/productos/ohmimetros/" title="Enlace a Ohmímetros en la web Amperis.com"&gt;medidores de aislamiento de resistencia&lt;/a&gt; [Enlace a Ohmímetros en la web Amperis.com] y poseen una escala bastante amplia.&lt;br /&gt;&lt;br /&gt;&lt;h4&gt;Uso del Ohmimetro&lt;/h4&gt;&lt;br /&gt;&lt;ul&gt;&lt;br /&gt;&lt;li&gt;La resistencia a medir no debe estar conectada a ninguna fuente de tensión o a ningún otro elemento del circuito, pues causan mediciones inexactas.&lt;/li&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;li&gt;Se debe ajustar a cero para evitar mediciones erráticas gracias a la falta de carga de la batería. En este caso, se debería de cambiar la misma&lt;/li&gt;&lt;br /&gt;&lt;br /&gt;&lt;li&gt;Al terminar de usarlo, es más seguro quitar la batería que dejarla, pues al dejar encendido el instrumento, la batería se puede descargar totalmente.&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;br /&gt;&lt;h4&gt;Utilidad del Ohmimetro&lt;/h4&gt;&lt;br /&gt;&lt;br /&gt;Su principal función consiste en conocer el valor &lt;span style="font-style: italic;"&gt;Ohmico&lt;/span&gt; de una resistencia desconocida y de esta forma, medir la continuidad de un conductor, y por supuesto detectar averías en circuitos desconocidos dentro los equipos&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-1889788897531345143?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/1889788897531345143/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=1889788897531345143' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1889788897531345143'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1889788897531345143'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/ohmimetro.html' title='Ohmimetro'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-1403670875418890366</id><published>2007-07-11T11:22:00.000-07:00</published><updated>2007-07-11T11:28:40.343-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='controles'/><category scheme='http://www.blogger.com/atom/ns#' term='osciloscopios'/><title type='text'>Controles Osciloscopio</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/osciloscopios/"&gt;&lt;img style="margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 97px; height: 283px;" src="http://www.amperis.com/images/osciloscopios/osciloscopio-waverider-100.jpg" alt="constroles osciloscopio" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;POWER: es el switch de encendido y apagado del &lt;a href="http://www.amperis.com/productos/osciloscopios/"&gt;osciloscopio&lt;/a&gt;. [va a las características completas en la web amperis.com]&lt;br /&gt;INTENSITY: ajusta la brillantez de la forma de onda para una mejor visualización.&lt;br /&gt;TRACE ROTATION: (rotación de trazo) rotando este control con un pequeño destornillador plano se puede ajustar la línea o trazo en forma horizontal.&lt;br /&gt;FOCUS: este control sirve para iluminar el despliegue en pantalla.&lt;br /&gt;CAL 0.5V: es una terminal para calibración de voltaje. Podemos conectar una de las puntas del osciloscopio en esta terminal y deberá aparecer en pantalla un voltaje de 0.5 Vpp de aproximadamente 1 Khz en forma de onda cuadrada.&lt;br /&gt;POSITION: es un control de ajuste para nivelar la señal  A en forma vertical.&lt;br /&gt;VOLTS/DIV VARIABLE FOR CH A : es un ajuste fino para cuando  seleccionamos Volts/div.&lt;br /&gt;VOLTS/DIV: es el control para cambiar de escala referente a voltaje por división para el canal A.&lt;br /&gt;NOTA: el control #4 deberá estar en la posición CAL.&lt;br /&gt;VERTICAL INPUT: es la entrada vertical para el canal A; aquí se conecta el cable para introducir una señal por el canal A.&lt;br /&gt;AC-GND-DC: es una palanca de 3 posiciones, las cuales son:&lt;br /&gt;a) posiciones AC: para cuando queramos desplegar una señal AC.&lt;br /&gt;b) Posición GND: es para indicar la tierra (Ground), en esta posición se despliega solamente un trazo horizontal (------)&lt;br /&gt;c) Posición DC: para cuando queramos desplegar una señal de voltaje DC.&lt;br /&gt;*NOTA: en algunos osciloscopios puede desplegarse una señal de voltaje AC aunque la posición de voltaje se encuentre en DC.&lt;br /&gt;COMP. TEST: (prueba de componentes) este control sirve para cambiar del modo osciloscopio al modo de probador de componentes (ver procedimiento en el manual).&lt;br /&gt;POSITION: en un control de ajuste para nivelar la señal del canal B en forma vertical.&lt;br /&gt;INVERT: botón que cuando es presionado invierte la polaridad vertical de la señal que está siendo visualizada mediante el canal B.&lt;br /&gt;VOLTS/DIV VARIABLE FOR CH B: ajuste fino para cuando utilizamos el canal B, debe ubicarse en la posición cal.&lt;br /&gt;VERTICAL INPUT: es la entrada vertical para el canal B, aquí se conecta el cable para introducir una señal para el canal B.&lt;br /&gt;AC-GND-DC: es la palanca equivalente a la #2 para manejar el canal B.&lt;br /&gt;A-ADD-B: son 3 botones que pueden actuar solos o combinadamente de acuerdo a como se indica a continuación.&lt;br /&gt;CH-A: si se presiona el botón A, se desplegara la señal captada por el canal B.&lt;br /&gt;CH-B: si se presiona el botón B, se desplegara la señal captada por el canal B.&lt;br /&gt;DUAL: pueden desplegarse las 2 señales al mismo tiempo, en cierto intervalo de tiempo por división.&lt;br /&gt;ADD: (adición) cuando se presiona este botón, las señales del canal A y B son sumadas.&lt;br /&gt;X5 MAG: cuando este botón es presionado, el barrido de tiempo es magnificado por 5 veces.&lt;br /&gt;POSITION ↔: sirve para ajustar la posición de la señal en el eje horizontal.&lt;br /&gt;SWEEP TIME/DIV VARIABLE: es un ajuste fino que acompaña al control time/div.&lt;br /&gt;SWEEP TIME/DIV: es un selector de diferentes escalas que permite modificar el barrido de tiempo por división de una señal.&lt;br /&gt;GND: (Ground - tierra) es la Terminal para conectar la tierra.&lt;br /&gt;SLOPE +-: es un botón para sincronizar una señal de acuerdo a la polaridad + -.&lt;br /&gt;AUTO: es un botón que al presionarlo, un auto barrido es efectuado. El barrido es puesto en un estado de libre ejecución aun cuando no se encuentre una señal de entrada aplicada. Nts lo utilizaremos a conveniencia para el  despliegue de las señales.&lt;br /&gt;LEVEL: es una perilla giratoria para ajustar el nivel de disparo de la señal. Nts lo utilizaremos para detener un poco la impresión de cuando una señal “parece que no la podemos detener”.&lt;br /&gt;COUPLING: es una palanca de 3 posiciones para diversos modos de sincronía:&lt;br /&gt;• AC: para operación normal.&lt;br /&gt;• C-LF: es un control par dejar pasar señales de cierta frecuencia nada más.&lt;br /&gt;• TV: sirve para manejar señales de televisión o video compuesto.&lt;br /&gt;&lt;br /&gt;EXT. INPUT: es una entrada para el disparo de una señal externa.&lt;br /&gt;SOURCE: (fuente) es un selector de señal de sincronía, sus posiciones son:&lt;br /&gt;• INT: las señales del canal A y B son sumadas en el disparo.&lt;br /&gt;• B: la señal es a partir del canal B.&lt;br /&gt;• LINE: una forma de onda AC es usada como fuente de sincronía.&lt;br /&gt;• EXT: esta posición se usa junto a la señal externa del disparo como fuente de sincronía.&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-1403670875418890366?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/1403670875418890366/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=1403670875418890366' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1403670875418890366'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1403670875418890366'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/controles-osciloscopio.html' title='Controles Osciloscopio'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-2544710941146372785</id><published>2007-07-11T11:14:00.000-07:00</published><updated>2007-07-11T11:15:10.694-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='absolutas'/><category scheme='http://www.blogger.com/atom/ns#' term='mediciones'/><category scheme='http://www.blogger.com/atom/ns#' term='patrones'/><title type='text'>Patrones medidas absolutas</title><content type='html'>&lt;span style="font-weight: bold;"&gt;Patrones principales y medidas absolutas&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;Los patrones principales del ohmio y el amperio de basan en definiciones de estas unidades aceptadas en el ámbito internacional y basadas en la masa, el tamaño del conductor y el tiempo. Las técnicas de medición que utilizan estas unidades básicas son precisas y reproducibles. Por ejemplo, las medidas absolutas de amperios implican la utilización de una especie de balanza que mide la fuerza que se produce entre un conjunto de bobinas fijas y una bobina móvil. Estas mediciones absolutas de intensidad de corriente y diferencia de potencial tienen su aplicación principal en el laboratorio, mientras que en la mayoría de los casos se utilizan medidas relativas. Todos los medidores que se describen en los párrafos siguientes permiten hacer lecturas relativas.&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-2544710941146372785?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/2544710941146372785/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=2544710941146372785' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/2544710941146372785'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/2544710941146372785'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/patrones-medidas-absolutas.html' title='Patrones medidas absolutas'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-29227413655787133</id><published>2007-07-11T11:13:00.000-07:00</published><updated>2007-07-11T11:14:04.427-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='mediciones'/><category scheme='http://www.blogger.com/atom/ns#' term='mecanismos'/><title type='text'>Mecanismos medidores</title><content type='html'>&lt;p&gt; Mecanismos básicos de los medidores&lt;/p&gt;&lt;p&gt;  Por su propia naturaleza, los valores eléctricos no pueden medirse por observación directa. Por ello se utiliza alguna propiedad de la electricidad para producir una fuerza física susceptible de ser detectada y medida. Por ejemplo, en el galvanómetro, el instrumento de medida inventado hace más tiempo, la fuerza que se produce entre un campo magnético y una bobina inclinada por la que pasa una corriente produce una desviación de la bobina. Dado que la desviación es proporcional a la intensidad de la corriente se utiliza una escala calibrada para medir la corriente eléctrica. La acción electromagnética entre corrientes, la fuerza entre cargas eléctricas y el calentamiento causado por una resistencia conductora son algunos de los métodos utilizados para obtener mediciones eléctricas analógicas.&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-29227413655787133?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/29227413655787133/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=29227413655787133' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/29227413655787133'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/29227413655787133'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/mecanismos-medidores.html' title='Mecanismos medidores'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-2613293621983663546</id><published>2007-07-11T11:11:00.000-07:00</published><updated>2007-07-11T11:12:50.289-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='resistencia'/><category scheme='http://www.blogger.com/atom/ns#' term='inductancia'/><category scheme='http://www.blogger.com/atom/ns#' term='capacidad'/><title type='text'>Resistencia, capacidad e inductancia</title><content type='html'>&lt;p&gt;Resistencia, capacidad e inductancia&lt;/p&gt;&lt;p&gt;Todos los componentes de un circuito eléctrico exhiben en mayor o menor medida una cierta resistencia, capacidad e inductancia. La unidad de resistencia comúnmente usada es el ohmio, que es la resistencia de un conductor en el que una diferencia de potencial de 1 voltio produce una corriente de 1 amperio. La capacidad de un condensador se mide en faradios: un condensador de 1 faradio tiene una diferencia de potencial entre sus placas de 1 voltio cuando éstas presentan una carga de 1 culombio. La unidad de inductancia es el henrio. Una bobina tiene una autoinductancia de 1 henrio cuando un cambio de 1 amperio/segundo en la corriente eléctrica que fluye a través de ella provoca una fuerza electromotriz opuesta de 1 voltio. Un transformador, o dos circuitos cualesquiera magnéticamente acoplados, tienen una inductancia mutua de 1 henrio cuando un cambio de 1 amperio por segundo en la corriente del circuito primario induce una tensión de 1 voltio en el circuito secundario.&lt;/p&gt;Dado que todas las formas de la materia presentan una o más características eléctricas es posible tomar mediciones eléctricas de un número ilimitado de fuentes&lt;p&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-2613293621983663546?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/2613293621983663546/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=2613293621983663546' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/2613293621983663546'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/2613293621983663546'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/resistencia-capacidad-e-inductancia.html' title='Resistencia, capacidad e inductancia'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6295568019503012308</id><published>2007-07-11T11:10:00.000-07:00</published><updated>2007-07-11T11:11:29.018-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='unidades'/><category scheme='http://www.blogger.com/atom/ns#' term='electricas'/><title type='text'>Unidades electricas</title><content type='html'>&lt;b&gt;UNIDADES ELECTRICAS&lt;/b&gt;  &lt;p&gt;Unidades eléctricas, unidades empleadas para medir cuantitativamente toda clase de fenómenos electrostáticos y electromagnéticos, así como las características electromagnéticas de los componentes de un circuito eléctrico. Las unidades eléctricas empleadas en técnica y ciencia se definen en el Sistema Internacional de unidades. Sin embargo, se siguen utilizando algunas unidades más antiguas.&lt;/p&gt;&lt;p&gt; Unidades SI &lt;/p&gt;&lt;p&gt; La unidad de intensidad de corriente en el Sistema Internacional de unidades es el amperio. La unidad de carga eléctrica es el culombio, que es la cantidad de electricidad que pasa en un segundo por cualquier punto de un circuito por el que fluye una corriente de 1 amperio. El voltio es la unidad SI de diferencia de potencial y se define como la diferencia de potencial que existe entre dos puntos cuando es necesario realizar un trabajo de 1 julio para mover una carga de 1 culombio de un punto a otro. La unidad de potencia eléctrica es el vatio, y representa la generación o consumo de 1 julio de energía eléctrica por segundo. Un kilovatio es igual a 1.000 vatios. &lt;/p&gt;&lt;p&gt; Las unidades también tienen las siguientes definiciones prácticas, empleadas para calibrar instrumentos: el amperio es la cantidad de electricidad que deposita 0,001118 gramos de plata por segundo en uno de los electrodos si se hace pasar a través de una solución de nitrato de plata; el voltio es la fuerza electromotriz necesaria para producir una corriente de 1 amperio a través de una resistencia de 1 ohmio, que a su vez se define como la resistencia eléctrica de una columna de mercurio de 106,3 cm de altura y 1 mm2 de sección transversal a una temperatura de 0 ºC. El voltio también se define a partir de una pila voltaica patrón, la denominada pila de Weston, con polos de amalgama de cadmio y sulfato de mercurio (I) y un electrólito de sulfato de cadmio. El voltio se define como 0,98203 veces el potencial de esta pila patrón a 20 ºC. &lt;/p&gt;&lt;p&gt;En todas las unidades eléctricas prácticas se emplean los prefijos convencionales del sistema métrico para indicar fracciones y múltiplos de las unidades básicas. Por ejemplo, un microamperio es una millonésima de amperio, un milivoltio es una milésima de voltio y 1 megaohmio es un millón de ohmios.&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6295568019503012308?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6295568019503012308/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6295568019503012308' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6295568019503012308'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6295568019503012308'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/unidades-electricas.html' title='Unidades electricas'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-4352559485941872271</id><published>2007-07-11T11:08:00.000-07:00</published><updated>2007-07-11T11:09:18.527-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='mediciones'/><category scheme='http://www.blogger.com/atom/ns#' term='electricas'/><title type='text'>Mediciones electricas</title><content type='html'>La importancia de los instrumentos eléctricos de medición es incalculable, ya que mediante el uso de ellos se miden e indican magnitudes eléctricas, como corriente, carga, potencial y energía, o las características eléctricas de los circuitos, como la resistencia, la capacidad, la capacitancia y la inductancia. Además que permiten localizar las causas de una operación defectuosa en aparatos eléctricos en los cuales, como es bien sabido, no es posible apreciar su funcionamiento en una forma visual, como en el caso de un aparato mecánico.&lt;p&gt; La información que suministran los instrumentos de medición eléctrica se da normalmente en una unidad eléctrica estándar: ohmios, voltios, amperios, culombios, henrios, faradios, vatios o julios.&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-4352559485941872271?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/4352559485941872271/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=4352559485941872271' title='1 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4352559485941872271'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/4352559485941872271'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/07/mediciones-electricas.html' title='Mediciones electricas'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-5172325861022626286</id><published>2007-06-25T08:46:00.000-07:00</published><updated>2007-06-25T08:50:52.776-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='telurometros'/><category scheme='http://www.blogger.com/atom/ns#' term='resistencia'/><title type='text'>Telurometro MRU-100-101</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/telurometros/mru/"&gt;&lt;img style="margin: 0pt 10px 10px 0pt; float: left; cursor: pointer;" src="http://amperis.com/images/telurometros/telurometro-mru-100-mru-101-g.jpg" alt="Telurómetro RMU 100/101" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Los telurómetros MRU-100/MRU-101 son &lt;a title="telurómetros" href="http://www.amperis.com/productos/telurometros/"&gt;telurómetros&lt;/a&gt; portátiles que miden la resistencia de puesta a tierra y la resistividad por el método de Wenner.&lt;/li&gt;&lt;li&gt;El instrumento puede medir resistencia y resistividad con 2, 3 ó 4 electrodos.&lt;/li&gt;&lt;li&gt;El equipo puede alimentarse con pilas estándar tipo C o con baterías de Ni-Cd.&lt;/li&gt;&lt;li&gt;Las medidas pueden simplificarse usando pinzas de corriente.&lt;/li&gt;&lt;/ul&gt; &lt;p&gt;&lt;strong&gt;Condiciones normales de operación:&lt;/strong&gt;&lt;/p&gt; &lt;ul&gt;&lt;li&gt;Corrientes erráticas durante la medida AC+DC: max. 24V.&lt;/li&gt;&lt;li&gt;Corriente de prueba: max. 225mA.&lt;/li&gt;&lt;li&gt;Medida de tensión: max. 40V.&lt;/li&gt;&lt;li&gt;Frecuencia de la corriente de prueba: 128Hz.&lt;/li&gt;&lt;li&gt;Temperatura de trabajo: 0..40°C.&lt;/li&gt;&lt;li&gt;Tensión de alimentación (para recargar la batería): 230V.&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;h2&gt;Características de los telurómetros MRU 100 y MRU 101:&lt;/h2&gt; &lt;ul&gt;&lt;li&gt;Medida de la resistencia de puesta a tierra de los electrodos usando una técnica de medida de 3 ó 4 polos.&lt;/li&gt;&lt;li&gt;Medida de la resistividad del terreno con la posibilidad de introducir la distancia entre electrodos (la resistividad se calcula automáticamente y se muestra en Ωm.&lt;/li&gt;&lt;li&gt;Medida de una resistencia metálica usando una técnica de dos o cuatro hilos.&lt;/li&gt;&lt;li&gt;Capacidad de llevar a cabo medidas de múltiples electrodos usando una técnica de tres polos sin desconectar los electrodos de tierra medidos (con el empleo de pinzas).&lt;/li&gt;&lt;li&gt;Chequeo de la medida de resistencia a tierra de los electrodos previamente a la medida de la resistencia de puesta a tierra con el objetivo de dar una precisión superior a la medida.&lt;/li&gt;&lt;li&gt;Alimentación con pilas normales o de Ni-Cd.&lt;/li&gt;&lt;li&gt;Cargador de baterías incorporado. &lt;/li&gt;&lt;li&gt;Señal del grado de carga de las baterías.  &lt;/li&gt;&lt;li&gt;Construido en una caja de cierre hermético.&lt;/li&gt;&lt;li&gt;Pantalla grande y con luz de fondo.&lt;/li&gt;&lt;li&gt;Memoria de 300 resultados. (telurómetro MRU 101).&lt;/li&gt;&lt;li&gt;Interfaz serie para PC RS-232C (telurómetro MRU 101).&lt;/li&gt;&lt;li&gt;Señal de batería baja.&lt;/li&gt;&lt;li&gt;Accesorios de calidad y diseño ergonómico.&lt;/li&gt;&lt;li&gt;Autoapagado.&lt;/li&gt;&lt;li&gt;Autorrango.&lt;/li&gt;&lt;li&gt;Caja de transporte.&lt;/li&gt;&lt;/ul&gt; &lt;p&gt;&lt;strong&gt;Normas que cumple el equipo:&lt;/strong&gt;&lt;/p&gt; &lt;ul&gt;&lt;li&gt;EN-61557-4.&lt;/li&gt;&lt;li&gt;EN-61557-5.&lt;/li&gt;&lt;li&gt;EN 61010-2-032.&lt;/li&gt;&lt;li&gt;Categoría de medida: Cat. III 300V EN 61010-1:2002.&lt;/li&gt;&lt;li&gt;Índice de protección: IP 54 EN 6529.&lt;/li&gt;&lt;/ul&gt; &lt;p&gt;&lt;strong&gt;Otros:&lt;/strong&gt;&lt;/p&gt; &lt;ul&gt;&lt;li&gt;Pantalla: LCD 3 digitos 20mm, con luz de fondo.&lt;/li&gt;&lt;li&gt;Dimensioness: 295 x 222 x 95mm.&lt;/li&gt;&lt;li&gt;Telurómetro MRU-100 peso con batería: ca. 1,6kg.&lt;/li&gt;&lt;li&gt;Telurómetro MRU-101 peso con batería NiCd: ca. 1,7kg.&lt;/li&gt;&lt;li&gt;Baterías: 5 pilas 1,5V R14 (tipo C) ó lote de pilas NiCd SONEL tipo 6ECF1800CS (telurómetro MRU-101 únicamente).&lt;/li&gt;&lt;li&gt;Duración de la batería: min. 2000 mediciones.&lt;/li&gt;&lt;li&gt;Autoapagado: 2 minutos de inactividad.&lt;/li&gt;&lt;li&gt;Tiempo de recarga de las  baterías: max. 3 horas.&lt;/li&gt;&lt;/ul&gt; &lt;p&gt;&lt;strong&gt;Tensión producida por corrientes erráticas (UN&lt;sub&gt;N&lt;/sub&gt;):&lt;/strong&gt;&lt;/p&gt; &lt;table width="100%"&gt;   &lt;tbody&gt;&lt;tr&gt;     &lt;td&gt;&lt;strong&gt;Rango&lt;/strong&gt;&lt;/td&gt;     &lt;td&gt;&lt;strong&gt;Resolución&lt;/strong&gt;&lt;/td&gt;     &lt;td&gt;&lt;strong&gt;Precisión&lt;/strong&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;0..40V&lt;/td&gt;     &lt;td&gt;1V&lt;/td&gt;     &lt;td&gt;±(10% v.m.+ 1 digit)&lt;/td&gt;   &lt;/tr&gt; &lt;/tbody&gt;&lt;/table&gt; &lt;p&gt;&lt;strong&gt;Medida de la resistencia de tierra (RE&lt;sub&gt;E&lt;/sub&gt;) &lt;span class="highlight"&gt;SIN&lt;/span&gt; pinzas de  corriente:&lt;/strong&gt;&lt;br /&gt;Rangos de medida de acuerdo con IEC 61557: 0,6Ω..20kΩ&lt;/p&gt; &lt;table width="100%"&gt;   &lt;tbody&gt;&lt;tr&gt;     &lt;td&gt;&lt;strong&gt;Rango&lt;/strong&gt;&lt;/td&gt;     &lt;td&gt;&lt;strong&gt;Resolución&lt;/strong&gt;&lt;/td&gt;     &lt;td&gt;&lt;strong&gt;Precisión&lt;/strong&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;0,00..9,99Ω&lt;/td&gt;     &lt;td&gt;0,01Ω&lt;/td&gt;     &lt;td&gt;±(2% m.v.+3 digitos)&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;10,0..99,9Ω&lt;/td&gt;     &lt;td&gt;0,1Ω&lt;/td&gt;     &lt;td rowspan="4"&gt;±(2% m.v.+2 digitos)&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;100..999Ω&lt;/td&gt;     &lt;td&gt;1Ω&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;1,00..9,99kΩ&lt;/td&gt;     &lt;td&gt;10Ω&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;10,0..20,0kΩ&lt;/td&gt;     &lt;td&gt;100Ω&lt;/td&gt;   &lt;/tr&gt; &lt;/tbody&gt;&lt;/table&gt;  &lt;p&gt;&lt;strong&gt;Medida de la resistencia de tierra (RE&lt;sub&gt;E&lt;/sub&gt;) &lt;span class="highlight"&gt;CON&lt;/span&gt; pinzas de  corriente:&lt;/strong&gt;&lt;br /&gt;Rangos de medida de acuerdo con IEC 61557: 0,8Ω..20kΩ&lt;/p&gt; &lt;table width="100%"&gt;   &lt;tbody&gt;&lt;tr&gt;     &lt;td&gt;&lt;strong&gt;Rango&lt;/strong&gt;&lt;/td&gt;     &lt;td&gt;&lt;strong&gt;Resolución&lt;/strong&gt;&lt;/td&gt;     &lt;td&gt;&lt;strong&gt;Precisión&lt;/strong&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;0,00..9,99Ω&lt;/td&gt;     &lt;td&gt;0,01Ω&lt;/td&gt;     &lt;td&gt;±(8% m.v.+3 digitos)&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;10,0..99,9Ω&lt;/td&gt;     &lt;td&gt;0,1Ω&lt;/td&gt;     &lt;td rowspan="4"&gt;±(8% m.v.+2 digitos)&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;100..999Ω&lt;/td&gt;     &lt;td&gt;1Ω&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;1,00..9,99kΩ&lt;/td&gt;     &lt;td&gt;10Ω&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;10,0..20,0kΩ&lt;/td&gt;     &lt;td&gt;100Ω&lt;/td&gt;   &lt;/tr&gt; &lt;/tbody&gt;&lt;/table&gt; &lt;p&gt;&lt;strong&gt;Medida de las resistencias de las estacas de prueba R&lt;sub&gt;H&lt;/sub&gt;, R&lt;sub&gt;S&lt;/sub&gt;:&lt;/strong&gt;&lt;/p&gt;  &lt;table width="100%"&gt;   &lt;tbody&gt;&lt;tr&gt;     &lt;td&gt;&lt;strong&gt;Precisión de la medida R&lt;sub&gt;S&lt;/sub&gt; y R&lt;sub&gt;H&lt;/sub&gt; &lt;span class="highlight"&gt;sin&lt;/span&gt; pinzas&lt;/strong&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;±5% de la suma de las medidas (R&lt;sub&gt;E&lt;/sub&gt;+R&lt;sub&gt;H&lt;/sub&gt;+R&lt;sub&gt;S&lt;/sub&gt;)&lt;/td&gt;   &lt;/tr&gt;     &lt;tr&gt;       &lt;td&gt;&lt;strong&gt;Precisión de la medida R&lt;sub&gt;S&lt;/sub&gt; y R&lt;sub&gt;H&lt;/sub&gt; &lt;span class="highlight"&gt;con&lt;/span&gt; pinzas&lt;/strong&gt;&lt;/td&gt;     &lt;/tr&gt;     &lt;tr&gt;       &lt;td&gt;±10% de la suma de las medidas (R&lt;sub&gt;E&lt;/sub&gt;+R&lt;sub&gt;H&lt;/sub&gt;+R&lt;sub&gt;S&lt;/sub&gt;)&lt;/td&gt;     &lt;/tr&gt;   &lt;/tbody&gt;&lt;/table&gt;   &lt;p&gt;=&gt; v.m.= valor medido&lt;br /&gt;=&gt; la precisión especificada no incluye un error de la distance a los electrodos (estacas) introducida por el usuario&lt;/p&gt; &lt;h2&gt;Accesorios incluidos&lt;/h2&gt; &lt;ul&gt;&lt;li&gt;Cable de prueba (longitud: 50 m) en un carrete con terminal banana, amarillo&lt;/li&gt;&lt;li&gt;Cable de prueba (longitud: 25 m) en un carrete con terminal banana, rojo&lt;/li&gt;&lt;li&gt;Cable de prueba de 1,2 m con terminal banana, amarillo&lt;/li&gt;&lt;li&gt;Cable de prueba de 2,2 m con terminal banana&lt;/li&gt;&lt;li&gt;Pinza cocodrilo, negra&lt;/li&gt;&lt;li&gt;Estaca para contacto de tierra, 30 cm, 2 unidades&lt;/li&gt;&lt;li&gt;Caja de transporte&lt;/li&gt;&lt;li&gt;Correa de sujeción&lt;/li&gt;&lt;li&gt;Manual&lt;/li&gt;&lt;li&gt;Certificado de calibración emitido por el fabricante&lt;/li&gt;&lt;li&gt;5 baterías R14&lt;/li&gt;&lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-5172325861022626286?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/5172325861022626286/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=5172325861022626286' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/5172325861022626286'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/5172325861022626286'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/06/telurometro-mru-100-101.html' title='Telurometro MRU-100-101'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-5898439479539835359</id><published>2007-06-20T15:50:00.000-07:00</published><updated>2007-06-20T15:53:43.146-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='cámaras térmicas'/><title type='text'>Tipos de Camaras Termograficas</title><content type='html'>&lt;strong&gt;&lt;/strong&gt; A continuación mostramos  las especificaciones generales de 4 &lt;span style="font-weight: bold;"&gt;Cámaras Termográficas:&lt;/span&gt;&lt;!--&lt;div class="help"&gt;Más informaci&amp;oacute;n: &lt;a title="Preguntas frecuentes sobre Micróhmetros" href="/productos/microhmetros/faq/"&gt;F.A.Q. (Preguntas Frecuentes)&lt;/a&gt; | &lt;a title="Apoyo Técnico, documentación sobre Micróhmetros" href="/productos/microhmetros/apoyo-tecnico/"&gt;Apoyo Técnico&lt;/a&gt;&lt;/div&gt; --&gt; &lt;table class="gb" width="100%"&gt;   &lt;tbody&gt;&lt;tr&gt;     &lt;td&gt;&lt;a title="Cámara Termográfica - Modelo T2E" href="http://www.amperis.com/productos/camaras-termograficas/t2e/"&gt;&lt;img src="http://www.amperis.com/images/camaras-termograficas/camara-termografica-t2-e-thumb.jpg" alt="cámara termografica modelo t2e" height="77" width="100" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt;&lt;a href="http://www.amperis.com/productos/camaras-termograficas/t2e/" title="Cámara Termográfica - Modelo T2E"&gt;&lt;strong&gt;T2E Cámara termográfica&lt;/strong&gt;&lt;/a&gt;&lt;br /&gt;Económica pero con imágenes de gran calidad. Detector de 160*120 y frecuencia de refresco de 50 Hz con lo cual las imágenes en movimiento se ven a la perfección. &lt;a href="http://www.amperis.com/productos/camaras-termograficas/t2e/" title="Cámara Termográfica - Modelo T2E"&gt;[leer más en Amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;&lt;a title="Cámara Termográfica - Modelo T2S" href="http://www.amperis.com/productos/camaras-termograficas/t2s/"&gt;&lt;img src="http://www.amperis.com/images/camaras-termograficas/camara-termografica-t2-s-thumb.jpg" alt="cámara termográfica modelo t2s" height="73" width="100" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt;&lt;a href="http://www.amperis.com/productos/camaras-termograficas/t2s/" title="Cámara Termográfica - Modelo T2S"&gt;&lt;strong&gt;T2S Cámara Termográfica&lt;/strong&gt;&lt;/a&gt; de las máximas prestaciones para el uso industrial. Rango  de temperaturas hasta 500ºC y mil imágenes de memoria&lt;br /&gt;      &lt;a href="http://www.amperis.com/productos/camaras-termograficas/t2s/" title="Cámara Termográfica - Modelo T2S"&gt;[Leer más en Amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;&lt;a title="Cámara Termográfica - Modelo T2P" href="http://www.amperis.com/productos/camaras-termograficas/t2p/"&gt;&lt;img src="http://www.amperis.com/images/camaras-termograficas/camara-termografica-t2-p-thumb.jpg" alt="Cámara Termog´rafica modelo tdp" height="73" width="100" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt;&lt;a href="http://www.amperis.com/productos/camaras-termograficas/t2p/" title="Cámara Termográfica - Modelo T2P"&gt;&lt;strong&gt;T2P Cámara termográfica profesional&lt;/strong&gt;&lt;/a&gt; con avanzadas prestaciones. Imagen de gran calidad (microbolómetro de 160*120 y frecuencia de refresco de 50 Hz). Memoria de hasta 1000 imágenes y anotaciones vocales hasta 40 segundos. &lt;a title="Cámara Termográfica - Modelo T2P" href="http://www.amperis.com/productos/camaras-termograficas/t2p/"&gt;[Leer más en Amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt;   &lt;tr&gt;     &lt;td&gt;&lt;a title="Cámara Termográfica - Modelo DL700" href="http://www.amperis.com/productos/camaras-termograficas/dl700/"&gt;&lt;img src="http://www.amperis.com/images/camaras-termograficas/camara-termografica-dl700e-thumb.jpg" alt="Cámara Termog´rafica modelo DL700" height="107" width="100" /&gt;&lt;/a&gt;&lt;/td&gt;     &lt;td&gt;&lt;a href="http://www.amperis.com/productos/camaras-termograficas/dl700/" title="Cámara Termográfica - Modelo DL700"&gt;&lt;strong&gt;DL700 Cámara Termográfica&lt;/strong&gt;&lt;/a&gt; de altísimas prestaciones. Detector de 320*240 lo cual le confiere una gran definición de imagen. Frecuencia de refresco de imagen 50 Hz. Memoria de hasta 3000 imágenes con anotaciones vocales. &lt;a title="Cámara Termográfica - Modelo DL700" href="http://www.amperis.com/productos/camaras-termograficas/dl700/"&gt;[Leer más en Amperis.com]&lt;/a&gt;&lt;/td&gt;   &lt;/tr&gt; &lt;/tbody&gt;&lt;/table&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-5898439479539835359?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/5898439479539835359/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=5898439479539835359' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/5898439479539835359'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/5898439479539835359'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/06/tipos-de-camaras-termograficas.html' title='Tipos de Camaras Termograficas'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-3211309692630033571</id><published>2007-06-19T18:01:00.000-07:00</published><updated>2007-06-20T15:55:58.186-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='cámaras termográficas'/><category scheme='http://www.blogger.com/atom/ns#' term='cámaras térmicas'/><category scheme='http://www.blogger.com/atom/ns#' term='termografía'/><title type='text'>Camaras Termograficas</title><content type='html'>&lt;span style="font-weight: bold; font-style: italic;font-size:130%;" &gt;&lt;blockquote&gt;¿Qué son las Cámaras Termográficas? ¿Para qué sirven?&lt;/blockquote&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/camaras-termograficas/"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://3.bp.blogspot.com/_liWG2cxeH1g/Rnh83a9TG2I/AAAAAAAAAAM/IrI9PZPR5sc/s200/radiacion-infrarroja-esquema-ondas.jpg" alt="Camaras termográficas" id="BLOGGER_PHOTO_ID_5077945871431310178" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Todos los materiales que estén una temperatura por encima del cero absoluto ( 0 K, -273ºC) emiten energía infrarroja. La energía emitida en la banda infrarroja se convierte en  una señal eléctrica por el detector (microbolómetro), esta señal se convierte en una imagen en blanco y negro o color. El principio básico se describe a continuación.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Radiación infrarroja&lt;/span&gt;&lt;br /&gt;La radiación infrarroja es una forma de radiación electromagnética como las ondas de radio, las microondas, rayos ultravioleta, rayos gamma, la luz visible, etc… Todas estas formas de radiación en conjunto dan lugar al espectro electromagnético. Tiene en común que todas ellas emiten energía en forma de ondas electromagnéticas y se propagan a la velocidad de la luz.&lt;br /&gt;&lt;br /&gt;La radiación infrarroja se define como aquella que tiene una longitud de onda entre 0,78 µm y 1000 µm (micras). Los rayos infrarrojos se subdividen en función de la proximidad de longitud de onda a la luz visible como cercanos, medios o lejanos.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Las cámaras termográficas que se emplean en la industria funcionan todas en la banda de infrarrojos medios (son las que detectan los llamados microbolómetros no refrigerados).&lt;br /&gt;&lt;br /&gt;Las cámaras termográficas detectan la radiación infrarroja invisible que emiten los objetos y lo transforma en una imagen dentro del espectro visible en la que la escala de colores (o grises) refleja las distintas intensidades.&lt;br /&gt;&lt;br /&gt;La intensidad de la radiación infrarroja es función de la temperatura pero no sólo de ella, influyen también las características superficiales del objeto, el color y el tipo de material.&lt;br /&gt;&lt;br /&gt;En un principio las cámaras termográficas dan un valor de temperatura para cada punto, sin tener en cuenta que, para la misma temperatura, dos materiales pueden irradiar energía infrarroja con intensidades muy diferentes.&lt;br /&gt;&lt;br /&gt;Vemos aquí un ejemplo muy gráfico, una taza metálica con un celo que están a la misma temperatura, sin embargo el celo y el metal de la taza emiten energía infrarroja con intensidades muy diferentes.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/camaras-termograficas/"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://1.bp.blogspot.com/_liWG2cxeH1g/Rnh9M69TG3I/AAAAAAAAAAU/u7Wx9nXwyQ4/s320/taza-metalica-cinta-adhesiva.jpg" alt="camaras termograficas" id="BLOGGER_PHOTO_ID_5077946240798497650" border="0" /&gt;&lt;/a&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/camaras-termograficas/"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://1.bp.blogspot.com/_liWG2cxeH1g/Rnh9i69TG4I/AAAAAAAAAAc/7IzYUMmkddY/s320/vision-camara-termografica.jpg" alt="camaras termograficas" id="BLOGGER_PHOTO_ID_5077946618755619714" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;Se debe a la diferente emisividad entre el metal y la cinta adhesiva.&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Emisividad&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;La emisividad de un objeto se define a partir del concepto de cuerpo negro. Un cuerpo negro es aquel que absorbe toda la radiación infrarroja que recibe, no refleja ni transmite por lo tanto nada. La radiación emitida por un cuerpo negro es función únicamente de la temperatura.&lt;br /&gt;&lt;br /&gt;La emisividad de un objeto para una temperatura se define como el cociente entre la energía infrarroja emitida por el objeto y la emitida por un cuerpo negro.&lt;br /&gt;&lt;br /&gt;Las cámaras termográficas adoptan como genera una emisividad de 0,95 a 0,97. Todas las cámaras de AMPERIS adoptan por defecto una emisividad de 0,95, y también todas permiten variar ese valor entre 0,1 y 1. De esta forma los diferentes valores de emisividad no se traducen en lecturas diferentes de temperatura.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Funcionamiento de una cámara termográfica&lt;/span&gt;&lt;br /&gt;esquema camara termografica&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_liWG2cxeH1g/Rnh-Kq9TG5I/AAAAAAAAAAk/gSgVt3vx-mw/s1600-h/esquema-funcionamiento-camara-termografica.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://4.bp.blogspot.com/_liWG2cxeH1g/Rnh-Kq9TG5I/AAAAAAAAAAk/gSgVt3vx-mw/s320/esquema-funcionamiento-camara-termografica.jpg" alt="" id="BLOGGER_PHOTO_ID_5077947301655419794" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Básicamente una cámara termográfica básica consta de:&lt;br /&gt;&lt;br /&gt; * Lentes&lt;br /&gt; * Filtro&lt;br /&gt; * Detector o microbolómetro&lt;br /&gt; * Circuito de procesado de la imagen&lt;br /&gt; * Interfaz de usuario (pantalla, salida de vídeo, memoria, etc…)&lt;br /&gt;&lt;br /&gt;A día de hoy menos de 15 compañías en el mundo son capaces de fabricar este tipo de cámaras.&lt;br /&gt;&lt;br /&gt;Un concepto muy importante a tener en cuenta a la hora de valorar una cámara de infrarrojos es la resolución espacial pues este concepto define hasta qué distancia se podrán ver los objetos.&lt;br /&gt;Resolución espacial&lt;br /&gt;&lt;br /&gt;La resolución espacial es el campo de visión de los microsensores que forman parte del detector o microbolómetro.&lt;br /&gt;resolución espacial cámara termográfica&lt;br /&gt;&lt;br /&gt;La resolución espacial se define como la relación entre el tamaño del sensor y la distancia entre las lentes y el sensor. Cuanto más baja sea la resolución espacial a más distancia se podrá utilizar la cámara (o, para la misma distancia, se podrán visualizar objetos más pequeños).&lt;br /&gt;&lt;br /&gt;En el siguiente gráfico se aprecia la relación entre el tamaño de los objetos y la distancia a la cámara:&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-3211309692630033571?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/3211309692630033571/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=3211309692630033571' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/3211309692630033571'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/3211309692630033571'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/06/camaras-termograficas.html' title='Camaras Termograficas'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_liWG2cxeH1g/Rnh83a9TG2I/AAAAAAAAAAM/IrI9PZPR5sc/s72-c/radiacion-infrarroja-esquema-ondas.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-100601996916200832</id><published>2007-06-15T05:08:00.000-07:00</published><updated>2007-06-15T05:25:40.768-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='de mano'/><category scheme='http://www.blogger.com/atom/ns#' term='osciloscopios'/><title type='text'>Osciloscopios de Mano</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/osciloscopios/"&gt;&lt;img style="margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 200px;" src="http://www.amperis.com/images/osciloscopios/pantalla-osciloscopios-preparada-medir-cursor.jpg" alt="pantalla osciloscopios" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;h4&gt;Osciloscopio WaveRider 100&lt;/h4&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;El osciloscopio de mano WaveRider 100 es un polivalente instrumento que aúna las funcionalidades de un osciloscopio tradicional, un multímetro y un registrador de onda.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;El osciloscopio WaveRider 100 le permitirá prescindir de cualquier otro equipo de medida en la gran mayoría de las aplicaciones.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;El manejo del osciloscopio es sencillo e intuitivo gracias a los menús que se despliegan en la pantalla.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Multímetro de verdadero valor eficaz, medidas de resistencia, continuidad y pruebas de diodos. Se suministra con una sonda de tensión de relación 10:1 para medidas de alta frecuencia.&lt;br /&gt;&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Con sólo 700 g es uno de los osciloscopios de mano más ligeros del mercado, además sus baterías de litio recargables le dan una gran movilidad.&lt;/li&gt;&lt;/ul&gt;&lt;h4&gt;General&lt;/h4&gt; &lt;ul&gt;&lt;li&gt;El osciloscopio WaveRider 100 permite utilizar el cursor de pantalla para medidas de amplitud o de tiempo.&lt;br /&gt;&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Se pueden grabar hasta 10 configuraciones de ajustes que se pueden recuperar en cualquier momento&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Asimismo se permite la grabación de hasta 6 formas de onda que pueden ser usadas como referencia cuando se precise.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;La función TRIGGER (disparo) permite la captura de transitorios o eventos no estacionales.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Función SMOOTHING de eliminación de ruido.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;Lengüeta trasera: utilización del aparato sobre una mesa o en el suelo&lt;/li&gt;&lt;/ul&gt;&lt;h4&gt;Osciloscopio WaveRider 100&lt;/h4&gt;&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-100601996916200832?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/100601996916200832/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=100601996916200832' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/100601996916200832'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/100601996916200832'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/06/osciloscopios-de-mano.html' title='Osciloscopios de Mano'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-7547368500414785707</id><published>2007-06-15T04:26:00.000-07:00</published><updated>2007-06-15T04:37:46.814-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='osciloscopios'/><title type='text'>Osciloscopios</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.amperis.com/productos/osciloscopios/"&gt;&lt;img style="float:right; margin:0 0 10px 10px;cursor:pointer; cursor:hand;width: 200px;" src="http://www.amperis.com/images/osciloscopios/osciloscopio-waverider-100.jpg" border="0" alt="osciloscopios" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight:bold;"&gt;¿Qué son los osciloscopios?&lt;/span&gt;&lt;br /&gt;&lt;br /&gt; Los &lt;span style="font-weight:bold;"&gt;osciloscopios&lt;/span&gt; son instrumentos de medida que registran gráficamente ondas de tensión, miden por lo tanto tensión (escala vertical) y tiempo (escala horizontal).&lt;br /&gt;Si se quiere ver una corriente normalmente debe usarse una pinza con salida en tensión.&lt;br /&gt;&lt;br /&gt;Modernamente añaden funciones adicionales como la captura de períodos transitorios (función trigger o disparo) o la representación gráfica de varios canales simultáneamente, memoria de varias pantallas, etc...&lt;br /&gt;&lt;br /&gt;Antiguamente las pantallas eran de rayos catódicos lo cual implicaba que los equipos eran bastante grandes y pesados, desde hace ya bastantes años sólo se fabrican del pantalla LCD lo cual permitió reducir mucho su tamaño, incluso hacerlos portátiles, &lt;br /&gt;&lt;br /&gt;Fuente(s):&lt;br /&gt;&lt;a href="http://www.amperis.com"&gt;Osciloscopios&lt;/a&gt; Amperis&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-7547368500414785707?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/7547368500414785707/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=7547368500414785707' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/7547368500414785707'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/7547368500414785707'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/06/osciloscopios.html' title='Osciloscopios'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-1061234501906975097</id><published>2007-06-06T20:11:00.001-07:00</published><updated>2007-06-06T20:11:53.202-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='telurometros'/><title type='text'>Telurometros</title><content type='html'>El mantenimiento de unos valores de resistencia en las puestas a tierra adecuados es esencial para la seguridad tanto de las personas como de la instalación. El telurómetro Terra-100 es un equipo de sencillo e intuitivo manejo que será su compañero en esa labor. Está equipado con 6 pila normales (1.5 V, tamaño AA) lo cual le dota de gran movilidad y autonomía. La pantalla LCD del telurómetro está equipada con luz de fondo lo cual permite la lectura en interiores oscuros.&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-1061234501906975097?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/1061234501906975097/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=1061234501906975097' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1061234501906975097'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/1061234501906975097'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/06/telurometros.html' title='Telurometros'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5684890127023020349.post-6665759230179688817</id><published>2007-06-06T19:32:00.000-07:00</published><updated>2007-06-19T18:11:17.420-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='ohmímetros'/><title type='text'>Ohmímetros</title><content type='html'>El &lt;a title="ohmimetro" href="http://www.amperis.com/productos/ohmimetros/"&gt;ohmimetro&lt;/a&gt; OME-10 utiliza el procedimiento de medida de los 4 hilos lo cual evita incluir en la medida la resistencia del cableado, esto permite su aplicación para la medida de resistencias bajas (conductores, puntos de soldadura, etc.).&lt;div class="blogger-post-footer"&gt;Más info en nuestra web corporativa &lt;a title="Amperis Products" href="http://www.amperis.com"&gt;Amperis Products&lt;/a&gt;.&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5684890127023020349-6665759230179688817?l=amperis-products.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://amperis-products.blogspot.com/feeds/6665759230179688817/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=5684890127023020349&amp;postID=6665759230179688817' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6665759230179688817'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5684890127023020349/posts/default/6665759230179688817'/><link rel='alternate' type='text/html' href='http://amperis-products.blogspot.com/2007/06/ohmmetros.html' title='Ohmímetros'/><author><name>Amperis</name><uri>http://www.blogger.com/profile/16351916057545573133</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://bp2.blogger.com/_liWG2cxeH1g/SDP51sA_mJI/AAAAAAAAAP8/TifIY2Hdqg4/S220/descargas-parciales.gif'/></author><thr:total>0</thr:total></entry></feed>
